Volumn , Issue , 2011, Pages 405-408

A comparative evaluation of ring artifacts reduction filters for X-ray computed microtomography images

Author keywords

computed tomography; filtering; image quality; ring artifacts; stripe artifacts

Indexed keywords

ARTIFICIAL IMAGE; COMPARATIVE EVALUATIONS; COMPUTED TOMOGRAPHY; CONCENTRIC RINGS; CRITICAL ANALYSIS; IMAGING DATA; MICRO-TOMOGRAPHY; NEGATIVE IMPACTS; QUALITATIVE ANALYSIS; RECONSTRUCTION PROCESS; RING ARTIFACTS; SINOGRAMS; STRIPE ARTIFACTS; TOMOGRAPHIC DATA; WORK-FLOWS; X-RAY COMPUTED MICROTOMOGRAPHY;

EID: 84856266878     PISSN: 15224880     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICIP.2011.6116535     Document Type: Conference Paper
Times cited : (12)

References (14)
  • 1
    • 77949569565 scopus 로고    scopus 로고
    • An improved method for ring artifacts removing in reconstructed tomographic images
    • F. Brun, G. Kourousias, D. Dreossi, and L. Mancini, "An improved method for ring artifacts removing in reconstructed tomographic images," IFMBE Proc., vol. 25, no. 4, pp. 926-929, 2009.
    • (2009) IFMBE Proc. , vol.25 , Issue.4 , pp. 926-929
    • Brun, F.1    Kourousias, G.2    Dreossi, D.3    Mancini, L.4
  • 2
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • J.F. Barrett and N. Keat, "Artifacts in CT: Recognition and avoidance," Radiographics, vol. 24, no. 6, pp. 1679-1691, 2004.
    • (2004) Radiographics , vol.24 , Issue.6 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 5
    • 66449087349 scopus 로고    scopus 로고
    • Stripe and ring artifact removal with combined wavelet-Fourier filtering
    • B. Münch, P. Trtik, F. Marone, and M. Stampanoni, "Stripe and ring artifact removal with combined wavelet-Fourier filtering," Opt. Express, vol. 17, no. 10, pp. 8567-8591, 2009.
    • (2009) Opt. Express , vol.17 , Issue.10 , pp. 8567-8591
    • Münch, B.1    Trtik, P.2    Marone, F.3    Stampanoni, M.4
  • 8
    • 70149093932 scopus 로고    scopus 로고
    • Comparison of ring artifact correction methods for flat-detector CT
    • D. Prell, Y. Kyriakou, andW.A. Kalender, "Comparison of ring artifact correction methods for flat-detector CT," Phys. Med. Biol., vol. 54, no. 12, pp. 3881-3895, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , Issue.12 , pp. 3881-3895
    • Prell, D.1    Kyriakou, Y.2    Kalender, W.A.3
  • 9
    • 84856279638 scopus 로고    scopus 로고
    • An efficient ring artifact reduction method based on projection data for micro-CT images
    • M.A. Yousuf and M. Asaduzzaman, "An efficient ring artifact reduction method based on projection data for micro-CT images," J. Sci. Res., vol. 2, no. 1, pp. 37-45, 2010.
    • (2010) J. Sci. Res. , vol.2 , Issue.1 , pp. 37-45
    • Yousuf, M.A.1    Asaduzzaman, M.2
  • 10
    • 33845462100 scopus 로고    scopus 로고
    • Compensation of ring artefacts in synchrotron tomographic images
    • DOI 10.1364/OE.14.012071
    • M. Boin and A. Haibel, "Compensation of ring artefacts in synchrotron tomographic images," Opt. Express, vol. 14, no. 25, pp. 12071-12075, 2006. (Pubitemid 44907547)
    • (2006) Optics Express , vol.14 , Issue.25 , pp. 12071-12075
    • Boin, M.1    Haibel, A.2
  • 11
    • 74149086487 scopus 로고    scopus 로고
    • Removal of ring artifacts in computed tomographic imaging using iterative center weighted median filter
    • F. Sadi, S.Y. Lee, and K. Hasan, "Removal of ring artifacts in computed tomographic imaging using iterative center weighted median filter," Comput. Biol. Med., vol. 40, no. 1, pp. 109-118, 2010.
    • (2010) Comput. Biol. Med. , vol.40 , Issue.1 , pp. 109-118
    • Sadi, F.1    Lee, S.Y.2    Hasan, K.3
  • 12
    • 4344716167 scopus 로고    scopus 로고
    • Reduction of ring artifacts in high resolution micro-CT reconstructions
    • J. Sijbers and A. Postnov, "Reduction of ring artifacts in high resolution micro-CT reconstructions," Phys. Med. Biol., vol. 49, no. 14, pp. 247-253, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , Issue.14 , pp. 247-253
    • Sijbers, J.1    Postnov, A.2
  • 13
    • 0000852127 scopus 로고    scopus 로고
    • Numerical removal of ring artifacts in microtomography
    • C. Raven, "Numerical removal of ring artifacts in microtomography," Rev. Sci. Instrum., vol. 69, no. 8, pp. 2978-2980, 2010.
    • (2010) Rev. Sci. Instrum. , vol.69 , Issue.8 , pp. 2978-2980
    • Raven, C.1
  • 14
    • 0029530359 scopus 로고
    • Image quality measures and their performance
    • A.M. Eskicioglu and P.S. Fisher, "Image quality measures and their performance," IEEE T. Commun., vol. 43, no. 12, pp. 2959-2965, 1995.
    • (1995) IEEE T. Commun. , vol.43 , Issue.12 , pp. 2959-2965
    • Eskicioglu, A.M.1    Fisher, P.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.