메뉴 건너뛰기




Volumn 34, Issue 3, 2011, Pages 327-332

A hybrid radiation detector for simultaneous spatial and temporal dosimetry

Author keywords

4D dosimetry; Dosimetry; Gel dosimetry; Radiation measurement; Radiotherapy

Indexed keywords

DOSE RATE; FEASIBILITY STUDIES; GEL DOSIMETER; GEL DOSIMETRY; IONISATION CHAMBER MEASUREMENTS; MEGAVOLTAGE; PLASTIC SCINTILLATOR; POLYMER GEL DOSIMETER; RADIATION FIELD; RADIATION INTENSITY; RADIATION MEASUREMENT; SPATIAL AND TEMPORAL VARIATION; SPATIAL MEASUREMENTS; TEMPORAL MEASUREMENTS;

EID: 84856265992     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/s13246-011-0081-5     Document Type: Article
Times cited : (5)

References (48)
  • 1
    • 0035996435 scopus 로고    scopus 로고
    • On the role of intensity-modulated radiation therapy in radiation oncology
    • DOI 10.1118/1.1487859
    • Schulz RJ, Kagan AR (2002) On the role of intensity-modulated radiation therapy in radiation oncology. Med Phys 29(7): 1473-1482 (Pubitemid 34774579)
    • (2002) Medical Physics , vol.29 , Issue.7 , pp. 1473-1482
    • Schulz, R.J.1    Kagan, A.R.2
  • 2
    • 72049096877 scopus 로고    scopus 로고
    • Comparison between hybrid direct aperture optimized intensity modulated radiotherapy and forward planning intensity modulated radiotherapy for whole breast irradiation
    • Descovich M, Fowble B, Bevan A, Shchechter N, Park C, Xia P (2010) Comparison between hybrid direct aperture optimized intensity modulated radiotherapy and forward planning intensity modulated radiotherapy for whole breast irradiation. Int J Radiat Oncol Biol Phys 76:91-99
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , pp. 91-99
    • Descovich, M.1    Fowble, B.2    Bevan, A.3    Shchechter, N.4    Park, C.5    Xia, P.6
  • 4
    • 33745488460 scopus 로고    scopus 로고
    • IMRT: A review and preview
    • Bortfield T (2006) IMRT: a review and preview. Phys Med Biol 51:R363-R379
    • (2006) Phys Med Biol , vol.51
    • Bortfield, T.1
  • 6
    • 0000321527 scopus 로고
    • The chemical action of roentgen rays on dilute ferrous sulfate solutions as a measure of radiation dose
    • Fricke H, Morse S (1927) The chemical action of roentgen rays on dilute ferrous sulfate solutions as a measure of radiation dose. Am J Roentgenol Radium Ther Nucl Med 18:430-432
    • (1927) Am J Roentgenol Radium Ther Nucl Med , vol.18 , pp. 430-432
    • Fricke, H.1    Morse, S.2
  • 7
    • 0021232591 scopus 로고
    • Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging
    • Gore JC, Kang YS, Schulz RJ (1984) Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. Phys Med Biol 29:1189-1197 (Pubitemid 14044533)
    • (1984) Physics in Medicine and Biology , vol.29 , Issue.10 , pp. 1189-1197
    • Gore, J.C.1    Kang, Y.S.2    Schulz, R.J.3
  • 8
    • 0025245033 scopus 로고
    • Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonance
    • Gore JC, Kang YS, Schulz RJ (1990) Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonance. Phys Med Biol 34:1611-1622
    • (1990) Phys Med Biol , vol.34 , pp. 1611-1622
    • Gore, J.C.1    Kang, Y.S.2    Schulz, R.J.3
  • 10
    • 36949090452 scopus 로고
    • Chemical effects of ionizing radiation in some gels
    • Day MJ, Stein G (1950) Chemical effects of ionizing radiation in some gels. Nature 166:1146-1147
    • (1950) Nature , vol.166 , pp. 1146-1147
    • Day, M.J.1    Stein, G.2
  • 13
    • 0027258459 scopus 로고
    • NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI
    • Maryanski MJ, Gore JC, Kennan RP, Schulz RJ (1993) NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. Magn Reson Imaging 11:253-258
    • (1993) Magn Reson Imaging , vol.11 , pp. 253-258
    • Maryanski, M.J.1    Gore, J.C.2    Kennan, R.P.3    Schulz, R.J.4
  • 15
    • 0035739868 scopus 로고    scopus 로고
    • Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere
    • DOI 10.1088/0031-9155/46/12/303, PII S003191550127314X
    • Fong PM, Keil DC, Does MD, Gore JC (2001) Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. Phys Med Biol 46:3105-3113 (Pubitemid 34568061)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.12 , pp. 3105-3113
    • Fong, P.M.1    Keil, D.C.2    Does, M.D.3    Gore, J.C.4
  • 16
    • 23744493423 scopus 로고    scopus 로고
    • Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging
    • DOI 10.1088/0031-9155/50/16/015
    • Venning A, Hill B, Brindha S, Healy BJ, Baldock C (2005) Investigation of PAGAT polymer gel dosimeter using magnetic resonance imaging. Phys Med Biol 50:3875-3888 (Pubitemid 41129157)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.16 , pp. 3875-3888
    • Venning, A.J.1    Hill, B.2    Brindha, S.3    Healy, B.J.4    Baldock, C.5
  • 17
    • 33749837882 scopus 로고    scopus 로고
    • Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
    • DOI 10.1093/rpd/nci555
    • Adamovics JA, Maryanski MJ (2006) Characterisation of PRESAGE (TM): a new 3-D radiochromic solid polymer dosemeter for ionising radiation. Radiat Prot Dosim 120:107-112 (Pubitemid 44559998)
    • (2006) Radiation Protection Dosimetry , vol.120 , Issue.1-4 , pp. 107-112
    • Adamovics, J.1    Maryanski, M.J.2
  • 18
    • 79953660591 scopus 로고    scopus 로고
    • Investigation of radiological properties and water equivalency of PRESAGE dosimeters
    • Gorjiara T, Hill R, Kuncic Z, Adamovics JA, Bosi S, Kim J, Baldock C (2011) Investigation of radiological properties and water equivalency of PRESAGE dosimeters. Med Phys 38(4):2265-2274
    • (2011) Med Phys , vol.38 , Issue.4 , pp. 2265-2274
    • Gorjiara, T.1    Hill, R.2    Kuncic, Z.3    Adamovics, J.A.4    Bosi, S.5    Kim, J.6    Baldock, C.7
  • 20
    • 36149040555 scopus 로고
    • A liquid ionisation detector for digital radiography of therapeutic megavoltage photon beams
    • Meertens H, van Herk M, Weeds J (1984) A liquid ionization detector for digital radiography of therapeutic megavoltage photon beams. Phys Med Biol 30:313-321 (Pubitemid 15110032)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.4 , pp. 313-321
    • Meertens, H.1    Van Herk, M.2    Weeda, J.3
  • 22
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • DOI 10.1118/1.1567831
    • Jursinic PA, Nelms BE (2003) A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys 30(5):870-879 (Pubitemid 36578690)
    • (2003) Medical Physics , vol.30 , Issue.5 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 23
    • 77957012057 scopus 로고    scopus 로고
    • Evaluation of a 3D diode array dosimeter for helical tomotherapy delivery QA
    • Feygelman V, Opp D, Javedan K, Saini AJ, Zhang G (2010) Evaluation of a 3D diode array dosimeter for helical tomotherapy delivery QA. Med Dosim 35(4):324-329
    • (2010) Med Dosim , vol.35 , Issue.4 , pp. 324-329
    • Feygelman, V.1    Opp, D.2    Javedan, K.3    Saini, A.J.4    Zhang, G.5
  • 24
    • 73649086212 scopus 로고    scopus 로고
    • Calibration of a novel four-dimensional diode array
    • Yan GH, Lu B, Kozelka J, Liu C, Li JG (2010) Calibration of a novel four-dimensional diode array. Med Phys 37(1):108-115
    • (2010) Med Phys , vol.37 , Issue.1 , pp. 108-115
    • Yan, G.H.1    Lu, B.2    Kozelka, J.3    Liu, C.4    Li, J.G.5
  • 26
    • 71049152525 scopus 로고    scopus 로고
    • Saint Gobain Saint Gobain Ceramics & Plastics, Louisville
    • Saint Gobain (2008) Scintillation products. Saint Gobain Ceramics & Plastics, Louisville
    • (2008) Scintillation Products
  • 27
    • 67650792446 scopus 로고    scopus 로고
    • Internal calibration of gel dosimeters: A feasibility study
    • 012014
    • Trapp JV, Kairn T, Crowe S, Fielding A (2009) Internal calibration of gel dosimeters: a feasibility study. J Phys 164 (012014):1-5
    • (2009) J Phys , vol.164 , pp. 1-5
    • Trapp, J.V.1    Kairn, T.2    Crowe, S.3    Fielding, A.4
  • 28
    • 34547311028 scopus 로고    scopus 로고
    • A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source
    • Williams K, Robinson N, Trapp JV, Ackerly T, Das R, Kemp P, Geso M (2007) A portable organic plastic scintillator dosimetry system for low energy X-rays: a feasibility study using an intraoperative X-ray unit as the radiation source. J Med Phys 32(2):73-76
    • (2007) J Med Phys , vol.32 , Issue.2 , pp. 73-76
    • Williams, K.1    Robinson, N.2    Trapp, J.V.3    Ackerly, T.4    Das, R.5    Kemp, P.6    Geso, M.7
  • 29
    • 78650579324 scopus 로고    scopus 로고
    • An investigation of the pre-irradiation temporal stability of PAGAT gel dosimeters
    • Khoei S, Moorrees JB, Langton CM, Trapp J (2010) An investigation of the pre-irradiation temporal stability of PAGAT gel dosimeters. J Phys 250:012019
    • (2010) J Phys , vol.250 , pp. 012019
    • Khoei, S.1    Moorrees, J.B.2    Langton, C.M.3    Trapp, J.4
  • 30
    • 31344459574 scopus 로고    scopus 로고
    • The fundamental radiation properties of normoxic polymer gel dosimeters: A comparison between a methacrylic acid based gel and acrylamide based gels
    • DOI 10.1088/0031-9155/51/3/012, PII S003191550601325X
    • De Deene Y, Vergote K, Claeys C, De Wagter C (2006) The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels. Phys Med Biol 51:653-673 (Pubitemid 43139110)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.3 , pp. 653-673
    • De Deene, Y.1    Vergote, K.2    Claeys, C.3    De Wagter, C.4
  • 31
    • 34547133466 scopus 로고    scopus 로고
    • Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation
    • DOI 10.1088/0031-9155/52/15/021, PII S0031915507501636, 021
    • Karlsson A, Gustavsson H, Mansson S, McAuley KB, Back SAJ (2007) Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation. Phys Med Biol 52:4697-4706 (Pubitemid 47103150)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.15 , pp. 4697-4706
    • Karlsson, A.1    Gustavsson, H.2    Mansson, S.3    McAuley, K.B.4    Back, S.A.J.5
  • 32
    • 0032770033 scopus 로고    scopus 로고
    • Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modelling oxygen diffusion
    • DOI 10.1088/0031-9155/44/8/302, PII S0031915599024240
    • Hepworth S, Leach MO, Doran SJ (1999) Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modelling oxygen diffusion. Phys Med Biol 44:1875-1884 (Pubitemid 29387598)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.8 , pp. 1875-1884
    • Hepworth, S.J.1    Leach, M.O.2    Doran, S.J.3
  • 33
    • 0034036208 scopus 로고    scopus 로고
    • An investigation of the chemical stability of a monomer/polymer gel dosimeter
    • DOI 10.1088/0031-9155/45/4/304, PII S0031915500094355
    • De Deene Y, Hanselaer P, De Wagter C, Achten E, De Neve W (2000) An investigation of the chemical stability of a monomer/polymer gel dosimeter. Phys Med Biol 45:859-878 (Pubitemid 30196381)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.4 , pp. 859-878
    • De Deene, Y.1    Hanselaer, P.2    De Wagter, C.3    Achten, E.4    De Neve, W.5
  • 34
    • 33947412370 scopus 로고    scopus 로고
    • Effect of container size on the accuracy of polymer gel dosimetry
    • Dumas E, Leclerc G, Lepage M (2006) Effect of container size on the accuracy of polymer gel dosimetry. J Phys 56:239-241
    • (2006) J Phys , vol.56 , pp. 239-241
    • Dumas, E.1    Leclerc, G.2    Lepage, M.3
  • 35
    • 34248176331 scopus 로고    scopus 로고
    • The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters
    • De Deene Y, Pittomvils G, Visalatchi S (2007) The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters. Phys Med Biol 52:2719-2728
    • (2007) Phys Med Biol , vol.52 , pp. 2719-2728
    • De Deene, Y.1    Pittomvils, G.2    Visalatchi, S.3
  • 36
    • 34250321745 scopus 로고    scopus 로고
    • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence
    • DOI 10.1088/0031-9155/52/13/022, PII S0031915507435783, 022
    • Taylor ML, Franich R, Johnston PN, Miller M, Trapp JV (2007) Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence. Phys Med Biol 52:3991-4005 (Pubitemid 46908608)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.13 , pp. 3991-4005
    • Taylor, M.L.1    Franich, R.D.2    Johnston, P.N.3    Millar, R.M.4    Trapp, J.V.5
  • 37
    • 64749102778 scopus 로고    scopus 로고
    • A comparative study of the effect of calibration conditions on the water equivalence of a range of gel dosimeters
    • Taylor ML, Franich R, Trapp JV, Johnston PN (2009) A comparative study of the effect of calibration conditions on the water equivalence of a range of gel dosimeters. IEEE Trans Nucl Sci 56(2):429-436
    • (2009) IEEE Trans Nucl Sci , vol.56 , Issue.2 , pp. 429-436
    • Taylor, M.L.1    Franich, R.2    Trapp, J.V.3    Johnston, P.N.4
  • 38
    • 33947433268 scopus 로고    scopus 로고
    • Absolute calibration of polymer gel dosimeter using scintillating fibres
    • Archambault L, Leclerc G, Beaulieu L, Lepage M (2006) Absolute calibration of polymer gel dosimeter using scintillating fibres. J Phys 56:242-244
    • (2006) J Phys , vol.56 , pp. 242-244
    • Archambault, L.1    Leclerc, G.2    Beaulieu, L.3    Lepage, M.4
  • 39
    • 78650562935 scopus 로고    scopus 로고
    • Improvement in the accuracy of polymer gel dosimeters using scintillating fibres
    • 1088
    • Tremblay NM, Hubert-Tremblay V, Bujold R, Beaulieu L, Lepage M (2010) Improvement in the accuracy of polymer gel dosimeters using scintillating fibres. J Phys 250:10.1088
    • (2010) J Phys , vol.250 , pp. 10
    • Tremblay, N.M.1    Hubert-Tremblay, V.2    Bujold, R.3    Beaulieu, L.4    Lepage, M.5
  • 42
    • 28244436540 scopus 로고
    • Radiation dosimetry by transparent plastics
    • Boag JW, Dolphin GW, Rotblat J (1958) Radiation dosimetry by transparent plastics. Radiat Res 9:589-610
    • (1958) Radiat Res , vol.9 , pp. 589-610
    • Boag, J.W.1    Dolphin, G.W.2    Rotblat, J.3
  • 43
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I physical characteristics and theoretical considerations
    • Beddar AS, Mackie TR, Attix FH (1992) Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I physical characteristics and theoretical considerations. Phys Med Biol 37(10):1883-1900
    • (1992) Phys Med Biol , vol.37 , Issue.10 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 44
    • 0027219790 scopus 로고
    • Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry
    • deBoer SF, Beddar AS, Rawlinson JA (1993) Optical filtering and spectral measurements of radiation induced light in plastic scintillation dosimetry. Phys Med Biol 38:945-958 (Pubitemid 23222821)
    • (1993) Physics in Medicine and Biology , vol.38 , Issue.7 , pp. 945-958
    • De Boer, S.F.1    Beddar, A.S.2    Rawlinson, J.A.3
  • 46
    • 45749136904 scopus 로고    scopus 로고
    • Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide
    • DOI 10.1088/0031-9155/53/11/021, PII S0031915508750449
    • Lambert J, Yin Y, McKenzie DR, Law S, Suchowerska N (2008) Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide. Phys Med Biol 53:3071-3080 (Pubitemid 351868624)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 3071-3080
    • Lambert, J.1    Yin, Y.2    McKenzie, D.R.3    Law, S.4    Suchowerska, N.5
  • 48
    • 0038107451 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry: Optimization of light collection efficiency
    • DOI 10.1088/0031-9155/48/9/305, PII S0031915503565459
    • Beddar AS, Law S, Suchowerska N, Mackie TR (2003) Plastic scintillation dosimetry: optimization of light collection efficiency. Phys Med Biol 48:1141-1152 (Pubitemid 36621467)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.9 , pp. 1141-1152
    • Beddar, A.S.1    Law, S.2    Suchowerska, N.3    Mackie, T.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.