Volumn 35, Issue 4, 2010, Pages 324-329

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

Author keywords

Delivery quality assurance; Detector validation; Diode array dosimeter; Helical tomotherapy

Indexed keywords

ACCURACY; ARTICLE; CALCULATION; CALIBRATION; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETER; FILM; IRRADIATION; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; THREE DIMENSIONAL DIODE ARRAY DOSIMETER; TOMOTHERAPY;

EID: 77957012057     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2009.10.007     Document Type: Article
Times cited : (38)

References (13)
  • 1
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • Jursinic P.A., Nelms B.E. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med. Phys. 2003, 30:870-879.
    • (2003) Med. Phys. , vol.30 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 2
    • 34247170048 scopus 로고    scopus 로고
    • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine
    • Herzen J., Todorovic M., Cremers F., et al. Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine. Phys. Med. Biol. 2007, 52:1197-1208.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 1197-1208
    • Herzen, J.1    Todorovic, M.2    Cremers, F.3
  • 3
    • 22244450090 scopus 로고    scopus 로고
    • Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    • Spezi E., Angelini A.L., Romani F., et al. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments. Phys. Med. Biol. 2005, 50:3361-3373.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 3361-3373
    • Spezi, E.1    Angelini, A.L.2    Romani, F.3
  • 4
    • 78049463176 scopus 로고    scopus 로고
    • Feasibility of using a 2D array detector to verify composite IMRT delivery for helical tomotherapy and linac
    • Shueng P., Chong N., Lee H., et al. Feasibility of using a 2D array detector to verify composite IMRT delivery for helical tomotherapy and linac. Int. J. Radiat. Oncol. Biol. Phys. 2008, 72:S675.
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.72
    • Shueng, P.1    Chong, N.2    Lee, H.3
  • 5
    • 78049461288 scopus 로고    scopus 로고
    • SU-GG-T-301: Evaluation of an ion chamber array for volume modulated radiation therapy and helical tomotherapy (abstract)
    • Neeley M., Ramsey C., Charara Y. SU-GG-T-301: Evaluation of an ion chamber array for volume modulated radiation therapy and helical tomotherapy (abstract). Med. Phys. 2008, 35:2794.
    • (2008) Med. Phys. , vol.35 , pp. 2794
    • Neeley, M.1    Ramsey, C.2    Charara, Y.3
  • 6
    • 34748872532 scopus 로고    scopus 로고
    • On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom
    • Van Esch A., Clermont C., Devillers M., et al. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom. Med. Phys. 2007, 34:3825-3837.
    • (2007) Med. Phys. , vol.34 , pp. 3825-3837
    • Van Esch, A.1    Clermont, C.2    Devillers, M.3
  • 7
    • 67649889107 scopus 로고    scopus 로고
    • Evaluation of the Delta4 phantom for IMRT and VMAT verification
    • Bedford J.L., Lee Y.K., Wai P., et al. Evaluation of the Delta4 phantom for IMRT and VMAT verification. Phys. Med. Biol. 2009, 54:N167-N176.
    • (2009) Phys. Med. Biol. , vol.54
    • Bedford, J.L.1    Lee, Y.K.2    Wai, P.3
  • 8
    • 69949149943 scopus 로고    scopus 로고
    • SU-FF-T-135: Delta4-A New IMRT QA Device (abstract)
    • Nilsson G. SU-FF-T-135: Delta4-A New IMRT QA Device (abstract). Med. Phys. 2007, 34:2432.
    • (2007) Med. Phys. , vol.34 , pp. 2432
    • Nilsson, G.1
  • 9
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D.A., Harms W.B., Mutic S., et al. A technique for the quantitative evaluation of dose distributions. Med. Phys. 1998, 25:656-661.
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3
  • 10
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • AAPM TG-21
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 1983, 10:741-771. AAPM TG-21.
    • (1983) Med. Phys. , vol.10 , pp. 741-771
  • 11
    • 54949105889 scopus 로고    scopus 로고
    • A new formalism for reference dosimetry of small and nonstandard fields
    • Alfonso R., Andreo P., Capote R., et al. A new formalism for reference dosimetry of small and nonstandard fields. Med. Phys. 2008, 35:5179-5186.
    • (2008) Med. Phys. , vol.35 , pp. 5179-5186
    • Alfonso, R.1    Andreo, P.2    Capote, R.3
  • 12
    • 61349101735 scopus 로고    scopus 로고
    • Static and rotational output variation of a tomotherapy unit
    • Francois P., Mazal A. Static and rotational output variation of a tomotherapy unit. Med. Phys. 2009, 36:816-820.
    • (2009) Med. Phys. , vol.36 , pp. 816-820
    • Francois, P.1    Mazal, A.2
  • 13
    • 31844441847 scopus 로고    scopus 로고
    • Assessing the effect of electron density in photon dose calculations
    • Seco J., Evans P.M. Assessing the effect of electron density in photon dose calculations. Med. Phys. 2006, 33:540-552.
    • (2006) Med. Phys. , vol.33 , pp. 540-552
    • Seco, J.1    Evans, P.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.