메뉴 건너뛰기




Volumn 14, Issue 1, 2012, Pages 61-66

Stability evaluation of implants integrated in grafted and nongrafted maxillary bone: A clinical study from implant placement to abutment connection

Author keywords

Bone graft; Implants; Stability

Indexed keywords

TITANIUM; TITANIUM DIOXIDE;

EID: 84856240424     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2010.00239.x     Document Type: Article
Times cited : (31)

References (13)
  • 1
    • 84856298218 scopus 로고    scopus 로고
    • On implant integration in membrane-induced and grafted bone. Thesis, Göteborg University, Göteborg, Sweden
    • Rasmusson L. On implant integration in membrane-induced and grafted bone. Thesis, Göteborg University, Göteborg, Sweden, 1998.
    • (1998)
    • Rasmusson, L.1
  • 2
    • 0033145562 scopus 로고    scopus 로고
    • The influence of simultaneous or delayed placement of titanium implants in onlay bone grafts. A histologic and biomechanic study in the rabbit
    • Rasmusson L, Meredith N, Cho IH, Sennerby L. The influence of simultaneous or delayed placement of titanium implants in onlay bone grafts. A histologic and biomechanic study in the rabbit. Int J Oral Maxillofac Surg 1999; 28:224-231.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 224-231
    • Rasmusson, L.1    Meredith, N.2    Cho, I.H.3    Sennerby, L.4
  • 3
    • 0033071266 scopus 로고    scopus 로고
    • Simultaneous or delayed placement of titanium implants in free autogenous iliac bone grafts. Histologic analysis of the bone graft - titanium interface in 10 consecutive patients
    • Lundgren S, Rasmusson L, Sjöström M, Sennerby L. Simultaneous or delayed placement of titanium implants in free autogenous iliac bone grafts. Histologic analysis of the bone graft - titanium interface in 10 consecutive patients. Int J Oral Maxillofac Surg 1999; 28:31-37.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 31-37
    • Lundgren, S.1    Rasmusson, L.2    Sjöström, M.3    Sennerby, L.4
  • 4
    • 0033302106 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis in the grafted maxilla. A cross-sectional pilot study
    • Rasmusson L, Stegersjö G, Kahnberg K-E, Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla. A cross-sectional pilot study. Clin Implant Dent Relat Res 1999; 1:70-74.
    • (1999) Clin Implant Dent Relat Res , vol.1 , pp. 70-74
    • Rasmusson, L.1    Stegersjö, G.2    Kahnberg, K.-E.3    Sennerby, L.4
  • 5
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissues interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissues interface using resonance frequency analysis. Clin Oral Implants Res 1996; 7:261-267.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 6
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997; 8:226-233.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 7
    • 0000277913 scopus 로고    scopus 로고
    • Mapping implant stability by resonance frequency analysis
    • Meredith N, Rasmusson L, Alleyne D. Mapping implant stability by resonance frequency analysis. Med Sci Res 1996; 34:191-193.
    • (1996) Med Sci Res , vol.34 , pp. 191-193
    • Meredith, N.1    Rasmusson, L.2    Alleyne, D.3
  • 9
    • 11844280921 scopus 로고    scopus 로고
    • Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6months of loading
    • Sjöström M, Lundgren S, Nilsson H, Sennerby L. Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6months of loading. Int J Oral Maxillofac Surg 2005; 34:45-51.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 45-51
    • Sjöström, M.1    Lundgren, S.2    Nilsson, H.3    Sennerby, L.4
  • 10
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 12
    • 0039966700 scopus 로고
    • Bone physiology and metabolism
    • Misch C, ed. St. Louis: Mosby Year Book
    • Robert E, Garetto L, Brezniak N. Bone physiology and metabolism. In: Misch C, ed. Contemporary implant dentistry. St. Louis: Mosby Year Book, 1994:327-368.
    • (1994) Contemporary implant dentistry , pp. 327-368
    • Robert, E.1    Garetto, L.2    Brezniak, N.3
  • 13
    • 84856288764 scopus 로고    scopus 로고
    • On the clinical measurement of implant stability and osseointegration. Dissertation, University of Gothenburg, Sweden
    • Meredith N. On the clinical measurement of implant stability and osseointegration. Dissertation, University of Gothenburg, Sweden, 1997.
    • (1997)
    • Meredith, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.