메뉴 건너뛰기




Volumn 67, Issue 2, 2012, Pages 322-325

The influence of field strength on the apparent diffusion coefficient of 3He gas in human lungs

Author keywords

ADC; field dependence; lung

Indexed keywords

BIOLOGICAL ORGANS; MAGNETIC SUSCEPTIBILITY; PHASE INTERFACES;

EID: 84856225301     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23187     Document Type: Article
Times cited : (20)

References (16)
  • 1
    • 0036136992 scopus 로고    scopus 로고
    • Emphysema: Hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes - Initial experience
    • Salerno M, de Lange EE, Altes TA, Truwit JD, Brookeman JR, Mugler JP,. Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes-initial experience. Radiology 2002; 222: 252-260. (Pubitemid 34031496)
    • (2002) Radiology , vol.222 , Issue.1 , pp. 252-260
    • Salerno, M.1    De Lange, E.E.2    Altes, T.A.3    Truwit, J.D.4    Brookeman, J.R.5    Mugler III, J.P.6
  • 6
    • 33750609824 scopus 로고    scopus 로고
    • Relationship between susceptibility induced field inhomogeneities, restricted diffusion, and relaxation in sedimentary rocks
    • DOI 10.1016/j.jmr.2006.07.006, PII S1090780706002114
    • Wilson RC, Hürlimann MD,. Relationship between susceptibility induced field inhomogeneities, restricted diffusion, and relaxation in sedimentary rocks. J Magn Reson 2006; 183: 1-12. (Pubitemid 44692513)
    • (2006) Journal of Magnetic Resonance , vol.183 , Issue.1 , pp. 1-12
    • Wilson, R.C.1    Hurlimann, M.D.2
  • 8
    • 78649450513 scopus 로고    scopus 로고
    • 3He lung morphometry technique: Accuracy analysis and pulse sequence optimization
    • 3He lung morphometry technique: accuracy analysis and pulse sequence optimization. J Magn Reson 2010; 207: 234-241.
    • (2010) J Magn Reson , vol.207 , pp. 234-241
    • Sukstanskii, A.L.1    Conradi, M.S.2    Yablonskiy, D.A.3
  • 10
    • 77955593655 scopus 로고    scopus 로고
    • Hyperpolarized 3He magnetic resonance imaging-derived pulmonary pressure-volume curves
    • Choy S, Wheatley A, McCormack DG, Parraga G,. Hyperpolarized 3He magnetic resonance imaging-derived pulmonary pressure-volume curves. J Appl Physiol 2010; 109: 574-585.
    • (2010) J Appl Physiol , vol.109 , pp. 574-585
    • Choy, S.1    Wheatley, A.2    McCormack, D.G.3    Parraga, G.4
  • 14
    • 0023951406 scopus 로고
    • Morphometry of the pulmonary acinus
    • Haefeli-Bleuer B, Weibel ER,. Morphometry of the pulmonary acinus. Anat Rec 1988; 220: 401-414.
    • (1988) Anat Rec , vol.220 , pp. 401-414
    • Haefeli-Bleuer, B.1    Weibel, E.R.2
  • 15
    • 42749094084 scopus 로고    scopus 로고
    • Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs
    • Parra-Robles J, Viqueira WD, Xu X, Ouriadov A, Santyr GE,. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs. J Magn Reson 2008; 192: 85-91.
    • (2008) J Magn Reson , vol.192 , pp. 85-91
    • Parra-Robles, J.1    Viqueira, W.D.2    Xu, X.3    Ouriadov, A.4    Santyr, G.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.