메뉴 건너뛰기




Volumn 67, Issue 2, 2012, Pages 419-427

Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI

Author keywords

acceleration; fMRI; Gibbs artifact; parallel imaging; SNR

Indexed keywords

ACCELERATION; BIOMEDICAL SIGNAL PROCESSING; MAGNETIC RESONANCE IMAGING; RESTORATION; SIGNAL RECONSTRUCTION; SIGNAL SAMPLING;

EID: 84856224025     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23025     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 30344470482 scopus 로고    scopus 로고
    • The cost of parallel imaging in functional MRI of the human brain
    • DOI 10.1016/j.mri.2005.10.028, PII S0730725X05003310
    • Lutcke H, Merboldt KD, Frahm J,. The cost of parallel imaging in functional MRI of the human brain. Magn Reson Imaging 2006; 24 (1): 1-5. (Pubitemid 43061197)
    • (2006) Magnetic Resonance Imaging , vol.24 , Issue.1 , pp. 1-5
    • Lutcke, H.1    Merboldt, K.-D.2    Frahm, J.3
  • 4
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • DOI 10.1002/jmri.20969
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO,. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007; 26 (2): 375-385. (Pubitemid 47257737)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.2 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 7
    • 33646836633 scopus 로고    scopus 로고
    • Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI
    • DOI 10.1016/j.neuroimage.2005.12.022, PII S1053811905025619
    • Chen NK, Oshio K, Panych LP,. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI. Neuroimage 2006; 31 (2): 609-622. (Pubitemid 43776658)
    • (2006) NeuroImage , vol.31 , Issue.2 , pp. 609-622
    • Chen, N.-k.1    Oshio, K.2    Panych, L.P.3
  • 8
    • 77953810026 scopus 로고    scopus 로고
    • Recovery of signal loss due to an in-plane susceptibility gradient in the gradient echo EPI through acquisition of extended phase-encoding lines
    • Jung KJ, Peng H, Zhao T, Avidan G, Behrmann M,. Recovery of signal loss due to an in-plane susceptibility gradient in the gradient echo EPI through acquisition of extended phase-encoding lines. Magn Reson Imaging 2010; 28 (6): 777-783.
    • (2010) Magn Reson Imaging , vol.28 , Issue.6 , pp. 777-783
    • Jung, K.J.1    Peng, H.2    Zhao, T.3    Avidan, G.4    Behrmann, M.5
  • 11
    • 53549094426 scopus 로고    scopus 로고
    • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions
    • Robson PM, Grant AK, Madhuranthakam AJ, Lattanzi R, Sodickson DK, McKenzie CA,. Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions. Magn Reson Med 2008; 60 (4): 895-907.
    • (2008) Magn Reson Med , vol.60 , Issue.4 , pp. 895-907
    • Robson, P.M.1    Grant, A.K.2    Madhuranthakam, A.J.3    Lattanzi, R.4    Sodickson, D.K.5    McKenzie, C.A.6
  • 12
    • 34648813638 scopus 로고    scopus 로고
    • Evaluation of motion effects on parallel MR imaging with precalibration
    • DOI 10.1016/j.mri.2007.01.117, PII S0730725X07001348
    • Guo JY, Kholmovski EG, Zhang L, Parker DL,. Evaluation of motion effects on parallel MR imaging with precalibration. Magn Reson Imaging 2007; 25 (8): 1130-1137. (Pubitemid 47464839)
    • (2007) Magnetic Resonance Imaging , vol.25 , Issue.8 , pp. 1130-1137
    • Guo, J.-Y.1    Kholmovski, E.G.2    Zhang, L.3    Parker, D.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.