-
1
-
-
30344470482
-
The cost of parallel imaging in functional MRI of the human brain
-
DOI 10.1016/j.mri.2005.10.028, PII S0730725X05003310
-
Lutcke H, Merboldt KD, Frahm J,. The cost of parallel imaging in functional MRI of the human brain. Magn Reson Imaging 2006; 24 (1): 1-5. (Pubitemid 43061197)
-
(2006)
Magnetic Resonance Imaging
, vol.24
, Issue.1
, pp. 1-5
-
-
Lutcke, H.1
Merboldt, K.-D.2
Frahm, J.3
-
2
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A,. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47 (6): 1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
3
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42 (5): 952-962. (Pubitemid 29521486)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.5
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
4
-
-
34547879249
-
Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
-
DOI 10.1002/jmri.20969
-
Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO,. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007; 26 (2): 375-385. (Pubitemid 47257737)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.2
, pp. 375-385
-
-
Dietrich, O.1
Raya, J.G.2
Reeder, S.B.3
Reiser, M.F.4
Schoenberg, S.O.5
-
5
-
-
33745685594
-
32-Channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
-
Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL,. 32-Channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006; 56 (1): 216-223.
-
(2006)
Magn Reson Med
, vol.56
, Issue.1
, pp. 216-223
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
6
-
-
0034850918
-
Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE)
-
DOI 10.1002/mrm.1226
-
Bammer R, Keeling SL, Augustin M, Pruessmann KP, Wolf R, Stollberger R, Hartung HP, Fazekas F,. Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 2001; 46 (3): 548-554. (Pubitemid 32831331)
-
(2001)
Magnetic Resonance in Medicine
, vol.46
, Issue.3
, pp. 548-554
-
-
Bammer, R.1
Keeling, S.L.2
Augustin, M.3
Pruessmann, K.P.4
Wolf, R.5
Stollberger, R.6
Hartung, H.-P.7
Fazekas, F.8
-
7
-
-
33646836633
-
Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI
-
DOI 10.1016/j.neuroimage.2005.12.022, PII S1053811905025619
-
Chen NK, Oshio K, Panych LP,. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI. Neuroimage 2006; 31 (2): 609-622. (Pubitemid 43776658)
-
(2006)
NeuroImage
, vol.31
, Issue.2
, pp. 609-622
-
-
Chen, N.-k.1
Oshio, K.2
Panych, L.P.3
-
8
-
-
77953810026
-
Recovery of signal loss due to an in-plane susceptibility gradient in the gradient echo EPI through acquisition of extended phase-encoding lines
-
Jung KJ, Peng H, Zhao T, Avidan G, Behrmann M,. Recovery of signal loss due to an in-plane susceptibility gradient in the gradient echo EPI through acquisition of extended phase-encoding lines. Magn Reson Imaging 2010; 28 (6): 777-783.
-
(2010)
Magn Reson Imaging
, vol.28
, Issue.6
, pp. 777-783
-
-
Jung, K.J.1
Peng, H.2
Zhao, T.3
Avidan, G.4
Behrmann, M.5
-
9
-
-
84941965835
-
-
Elsevier Academic Press: Burlington, MA, USA
-
Bernstein M, King K, Zhou X,. Handbook of MRI pulse sequences. Elsevier Academic Press: Burlington, MA, USA; 2004.
-
(2004)
Handbook of MRI Pulse Sequences
-
-
Bernstein, M.1
King, K.2
Zhou, X.3
-
11
-
-
53549094426
-
Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions
-
Robson PM, Grant AK, Madhuranthakam AJ, Lattanzi R, Sodickson DK, McKenzie CA,. Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions. Magn Reson Med 2008; 60 (4): 895-907.
-
(2008)
Magn Reson Med
, vol.60
, Issue.4
, pp. 895-907
-
-
Robson, P.M.1
Grant, A.K.2
Madhuranthakam, A.J.3
Lattanzi, R.4
Sodickson, D.K.5
McKenzie, C.A.6
-
12
-
-
34648813638
-
Evaluation of motion effects on parallel MR imaging with precalibration
-
DOI 10.1016/j.mri.2007.01.117, PII S0730725X07001348
-
Guo JY, Kholmovski EG, Zhang L, Parker DL,. Evaluation of motion effects on parallel MR imaging with precalibration. Magn Reson Imaging 2007; 25 (8): 1130-1137. (Pubitemid 47464839)
-
(2007)
Magnetic Resonance Imaging
, vol.25
, Issue.8
, pp. 1130-1137
-
-
Guo, J.-Y.1
Kholmovski, E.G.2
Zhang, L.3
Parker, D.L.4
|