-
1
-
-
0030861441
-
Odor, drug and toxin analysis with neuronal networks in vitro: Extracellular array recording of network responses
-
DOI 10.1016/S0956-5663(97)00012-2, PII S0956566397000122
-
G.W. Gross, A. Harsch, B.K. Rhoades, and W. Göpel Odor, drug and toxin analysis with neuronal networks in vitro: extracellular array recording of network responses Biosens. Bioelectron. 12 1997 373 393 (Pubitemid 27292794)
-
(1997)
Biosensors and Bioelectronics
, vol.12
, Issue.5
, pp. 373-393
-
-
Gross, G.W.1
Harsch, A.2
Rhoades, B.K.3
Gopel, W.4
-
2
-
-
12444250041
-
A portable microelectrode array recording system incorporating cultured neuronal networks for neurotoxin detection
-
DOI 10.1016/S0956-5663(03)00092-7
-
J.J. Pancrazio, S.A. Gray, Y.S. Shubin, N. Kulagina, D.S. Cuttino, K.M. Shaffer, K. Eisemann, A. Curran, B. Zim, and T.J. O'Shaughnessy A portable microelectrode array recording system incorporating cultured neuronal networks for neurotoxin detection Biosens. Bioelectron. 18 2003 1339 1347 (Pubitemid 36929967)
-
(2003)
Biosensors and Bioelectronics
, vol.18
, Issue.11
, pp. 1339-1347
-
-
Pancrazio, J.J.1
Gray, S.A.2
Shubin, Y.S.3
Kulagina, N.4
Cuttino, D.S.5
Shaffer, K.M.6
Eisemann, K.7
Curran, A.8
Zim, B.9
Gross, G.W.10
O'Shaughnessy, T.J.11
-
3
-
-
0034861754
-
Characterization of acute neurotoxic effects of trimethylolpropane phosphate via neuronal network biosensors
-
DOI 10.1016/S0956-5663(01)00165-8, PII S0956566301001658
-
E.W. Keefer, A. Gramowski, D.A. Stenger, J.J. Pancrazio, and G.W. Gross Characterization of acute neurotoxic effects of trimethylolpropane phosphate via neuronal network biosensors Biosens. Bioelectron. 16 2001 513 525 (Pubitemid 32816918)
-
(2001)
Biosensors and Bioelectronics
, vol.16
, Issue.7-8
, pp. 513-525
-
-
Keefer, E.W.1
Gramowski, A.2
Stenger, D.A.3
Pancrazio, J.J.4
Gross, G.W.5
-
4
-
-
0033220420
-
Development and Application of Cell-Based Biosensors
-
J.J. Pancrazio, J.P. Whelan, D.A. Borkholder, W. Ma, and D.A. Stenger Development and application of cell-based biosensors Ann. Biomed. Eng. 27 1999 697 711 (Pubitemid 129583988)
-
(1999)
Annals of Biomedical Engineering
, vol.27
, Issue.6
, pp. 697-711
-
-
Pancrazio, J.J.1
Whelan, J.P.2
Borkholder, D.A.3
Ma, W.4
Stenger, D.A.5
-
5
-
-
0035426409
-
Detection of physiologically active compounds using cell-based biosensors
-
DOI 10.1016/S0167-7799(01)01690-0, PII S0167779901016900
-
D.A. Stenger, G.W. Gross, E.W. Keefer, K.M. Shaffer, J.D. Andreadis, W. Ma, and J.J. Pancrazio Detection of physiologically active compounds using cell-based biosensors Trends Biotechnol. 19 2001 304 309 (Pubitemid 32635188)
-
(2001)
Trends in Biotechnology
, vol.19
, Issue.8
, pp. 304-309
-
-
Stenger, D.A.1
Gross, G.W.2
Keefer, E.W.3
Shaffer, K.M.4
Andreadis, J.D.5
Ma, W.6
Pancrazio, J.J.7
-
6
-
-
0034861828
-
Design and demonstration of an automated cell-based biosensor
-
DOI 10.1016/S0956-5663(01)00167-1, PII S0956566301001671
-
S.A. Gray, J.K. Kusel, K.M. Shaffer, Y.S. Shubin, D.A. Stenger, and J.J. Pancrazio Design and demonstration of an automated cell-based biosensor Biosens. Bioelectron. 16 2001 535 542 (Pubitemid 32816920)
-
(2001)
Biosensors and Bioelectronics
, vol.16
, Issue.7-8
, pp. 535-542
-
-
Gray, S.A.1
Kusel, J.K.2
Shaffer, K.M.3
Shubin, Y.S.4
Stenger, D.A.5
Pancrazio, J.J.6
-
8
-
-
0035783996
-
Distributed processing in cultured neuronal networks
-
M. Nicolelis, Elsevier Amsterdam
-
S.M. Potter Distributed processing in cultured neuronal networks M. Nicolelis, Progress in Brain Research: Advances in Neural Population Coding vol. 130 2001 Elsevier Amsterdam 49 62
-
(2001)
Progress in Brain Research: Advances in Neural Population Coding
, vol.130
, pp. 49-62
-
-
Potter, S.M.1
-
9
-
-
0034221337
-
The dynamics of a neuronal culture of dissociated cortical neurons of neonatal rats
-
Y. Jimbo, A. Kawana, P. Parodi, and V. Torre The dynamics of a neuronal culture of dissociated cortical neurons of neonatal rats Biol. Cybern. 83 2000 1 20
-
(2000)
Biol. Cybern.
, vol.83
, pp. 1-20
-
-
Jimbo, Y.1
Kawana, A.2
Parodi, P.3
Torre, V.4
-
10
-
-
0017759085
-
A new fixed-array multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro
-
G.W. Gross, E. Rieske, G.W. Kreutzberg, and A. Meyer A new fixed-array multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro Neurosci. Lett. 6 1977 101 105 (Pubitemid 8238479)
-
(1977)
Neuroscience Letters
, vol.6
, Issue.2-3
, pp. 101-105
-
-
Gross, G.W.1
Rieske, E.2
Kreutzberg, G.W.3
Meyer, A.4
-
11
-
-
0018331316
-
Simultaneous single unit recording in vitro with a photoetched laser deinsulated gold multimicroelectrode surface
-
G.W. Gross Simultaneous single unit recording in vitro with a photoetched, laser-deinsulated, gold multimicroelectrode surface IEEE Trans. Biomed. Eng. 26 1979 273 279 (Pubitemid 9170144)
-
(1979)
IEEE Transactions on Biomedical Engineering
, vol.26
, Issue.5
, pp. 273-279
-
-
Gross, G.W.1
-
12
-
-
0022367558
-
Transparent indium - tin oxide electrode patterns for extracellular, multisite recording in neuronal cultures
-
DOI 10.1016/0165-0270(85)90105-0
-
G.W. Gross, W. Wen, and J. Lin Transparent indium-tin oxide patterns for extra-cellular, multisite recording in neuronal culture J. Neurosci. Methods 15 1985 243 252 (Pubitemid 16181440)
-
(1985)
Journal of Neuroscience Methods
, vol.15
, Issue.3
, pp. 243-252
-
-
Gross, G.W.1
Wen, W.Y.2
Lin, J.W.3
-
13
-
-
2942559178
-
Substance identification by quantitative characterization of oscillatory activity in murine spinal cord networks on microelectrode arrays
-
DOI 10.1111/j.0953-816X.2004.03373.x
-
A. Gramowski, K. Jugelt, D.G. Weiss, and G.W. Gross Substance identification by quantitative characterization of oscillatory activity in murine spinal cord networks on microelectrode arrays Eur. J. Neurosci. 19 2004 2815 2825 (Pubitemid 38746398)
-
(2004)
European Journal of Neuroscience
, vol.19
, Issue.10
, pp. 2815-2825
-
-
Gramowski, A.1
Jugelt, K.2
Weiss, D.G.3
Gross, G.W.4
-
15
-
-
4043049325
-
CMOS microelectrode array for the monitoring of electrogenic cells
-
DOI 10.1016/j.bios.2004.02.006, PII S0956566304000806
-
F. Heer, W. Franks, A. Blau, S. Taschini, C. Ziegler, A. Hierlemann, and H. Baltes CMOS microelectrode array for the monitoring of electrogenic cells Biosens. Bioelectron. 20 2004 358 366 (Pubitemid 39077641)
-
(2004)
Biosensors and Bioelectronics
, vol.20
, Issue.2
, pp. 358-366
-
-
Heer, F.1
Franks, W.2
Blau, A.3
Taschini, S.4
Ziegler, C.5
Hierlemann, A.6
Baltes, H.7
-
16
-
-
0034884441
-
Single-unit neural recording with active microelectrode arrays
-
DOI 10.1109/10.936367, PII S0018929401061584
-
Q. Bai, and K.D. Wise Single-unit neural recording with active microelectrode arrays IEEE Trans. Biomed. Eng. 48 2001 911 920 (Pubitemid 32703043)
-
(2001)
IEEE Transactions on Biomedical Engineering
, vol.48
, Issue.8
, pp. 911-920
-
-
Bai, Q.1
Wise, K.D.2
-
18
-
-
0035298778
-
Monolithic capillary electrophoresis device with integrated fluorescence detector
-
DOI 10.1021/ac0004512
-
J.R. Webster, M.A. Burns, D.T. Burke, and C.H. Mastrangelo Monolithic capillary electrophoresis device with integrated fluorescence detector Anal. Chem. 73 2001 1622 1626 (Pubitemid 32896224)
-
(2001)
Analytical Chemistry
, vol.73
, Issue.7
, pp. 1622-1626
-
-
Webster, J.R.1
Burns, M.A.2
Burke, D.T.3
Mastrangelo, C.H.4
-
19
-
-
18744384648
-
Parylene flexible neural probes integrated with microfluidic channels
-
DOI 10.1039/b417497f
-
S. Takeuchi, D. Ziegler, Y. Yoshida, K. Mabuchi, and T. Susuki Parylene flexible neural probes integrated with microfluidic channels Lab Chip 5 2005 519 523 (Pubitemid 40676818)
-
(2005)
Lab on a Chip - Miniaturisation for Chemistry and Biology
, vol.5
, Issue.5
, pp. 519-523
-
-
Takeuchi, S.1
Ziegler, D.2
Yoshida, Y.3
Mabuchi, K.4
Suzuki, T.5
-
20
-
-
33846934978
-
Integrated flexible ocular coil for power and data transfer in retinal prostheses
-
1616593, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
-
W. Li, D. Rodger, J. Weiland, M. Humayun, and Y. Tai Integrated flexible ocular coil for power and data transfer in retinal prostheses Conf. Proc. IEEE Eng. Med. Biol. Soc. 1 2005 1028 1031 (Pubitemid 46229044)
-
(2005)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, vol.7
, pp. 1028-1031
-
-
Li, W.1
Rodger, D.C.2
Weiland, J.D.3
Humayun, M.S.4
Tai, Y.C.5
-
21
-
-
33751256573
-
Flexible multielectrodes can resolve multiple muscles in an insect appendage
-
DOI 10.1016/j.jneumeth.2006.07.002, PII S0165027006003189
-
A.J. Spence, K.B. Neeves, D. Murphy, S. Sponberg, B.R. Land, R.R. Hoy, and M.S. Isaacson Flexible multielectrodes can resolve multiple muscles in an insect appendage J. Neurosci. Methods 159 2007 116 124 (Pubitemid 44792283)
-
(2007)
Journal of Neuroscience Methods
, vol.159
, Issue.1
, pp. 116-124
-
-
Spence, A.J.1
Neeves, K.B.2
Murphy, D.3
Sponberg, S.4
Land, B.R.5
Hoy, R.R.6
Isaacson, M.S.7
-
22
-
-
0017368305
-
Parylene as a chronically stable, reproducible microelectrode insulator
-
G.E. Loeb, M.J. Bak, M. Salcman, and E.M. Schmidt Parylene as a chronically stable, reproducible microelectrode insulator IEEE Trans. Biomed. Eng. 24 1977 121 128 (Pubitemid 8125041)
-
(1977)
IEEE Transactions on Biomedical Engineering
, vol.24
, Issue.2
, pp. 121-128
-
-
Loeb, G.E.1
Bak, M.J.2
Salcman, M.3
Schmidt, E.M.4
-
23
-
-
62649137024
-
Solzbacher, Integrated wireless neural interface based on the Utah electrode array
-
S. Kim, R. Bhandari, M. Klein, S. Negi, L. Rieth, P. Tathireddy, M. Toepper, and H.F. Oppermann Solzbacher, Integrated wireless neural interface based on the Utah electrode array Biomed. Microdevices 11 2009 453 466
-
(2009)
Biomed. Microdevices
, vol.11
, pp. 453-466
-
-
Kim, S.1
Bhandari, R.2
Klein, M.3
Negi, S.4
Rieth, L.5
Tathireddy, P.6
Toepper, M.7
Oppermann, H.F.8
-
24
-
-
84856216314
-
-
USA Patent 5,780,130
-
J.E. Hansen, K. Osakada, M.J. Myers, Container and method of making container from polyethylene naphthalate and copolymers thereof, USA Patent 5,780,130 (1998).
-
(1998)
Container and Method of Making Container from Polyethylene Naphthalate and Copolymers Thereof
-
-
Hansen, J.E.1
Osakada, K.2
Myers, M.J.3
-
25
-
-
0347612318
-
Using electronic circuits to model simple neuroelectric interactions
-
E.R. Lewis Using electronic circuits to model simple neuroelectric interactions Proc. IEEE 56 1968 931 949
-
(1968)
Proc. IEEE
, vol.56
, pp. 931-949
-
-
Lewis, E.R.1
-
26
-
-
0029584238
-
A model of spike initiation in neocortical pyramidal neurons
-
DOI 10.1016/0896-6273(95)90020-9
-
Z.F. Mainen, J. Joerges, J.R. Huguenard, and T.J. Sejnowski A model of spike initiation in neocortical pyramidal neurons Neuron 15 1995 1427 1439 (Pubitemid 26005379)
-
(1995)
Neuron
, vol.15
, Issue.6
, pp. 1427-1439
-
-
Mainen, Z.F.1
Joerges, J.2
Huguenard, J.R.3
Sejnowski, T.J.4
-
27
-
-
0023271966
-
Brain sizes, surfaces, and neuronal sizes of the cortex cerebri: A stereological investigation of man and his variability and a comparison with some mammals (primates, whales, marsupials, insectivores, and one elephant)
-
H. Haug Brain sizes, surfaces, and neuronal sizes of the cortex cerebri: a stereological investigation of man and his variability and a comparison with some mammals (primates, whales, marsupials, insectivores, and one elephant) Am. J. Anat. 180 1987 126 142 (Pubitemid 17148455)
-
(1987)
American Journal of Anatomy
, vol.180
, Issue.2
, pp. 126-142
-
-
Haug, H.1
-
28
-
-
0025792070
-
Finite-element analysis applied to extracellular microelectrode design
-
R. Lind, P. Connolly, C. Wilkinson, and R. Thomson Finite-element analysis applied to extracellular microelectrode design Sens. Actuators B 3 1991 23 30
-
(1991)
Sens. Actuators B
, vol.3
, pp. 23-30
-
-
Lind, R.1
Connolly, P.2
Wilkinson, C.3
Thomson, R.4
-
29
-
-
38349070646
-
A new 3-D finite-element model based on thin-film approximation for microelectrode array recording of extracellular action potential
-
C. Moulin, A. Gliere, D. Barbier, S. Joucla, B. Yvert, P. Mailley, and R. Guillemaud A new 3-D finite-element model based on thin-film approximation for microelectrode array recording of extracellular action potential IEEE Trans. Biomed. Eng. 55 2008 683 692
-
(2008)
IEEE Trans. Biomed. Eng.
, vol.55
, pp. 683-692
-
-
Moulin, C.1
Gliere, A.2
Barbier, D.3
Joucla, S.4
Yvert, B.5
Mailley, P.6
Guillemaud, R.7
-
30
-
-
50249084472
-
Neural stimulation and recording electrodes
-
S.F. Cogan Neural stimulation and recording electrodes Ann. Rev. Biomed. Eng. 10 2008 275 309
-
(2008)
Ann. Rev. Biomed. Eng.
, vol.10
, pp. 275-309
-
-
Cogan, S.F.1
-
31
-
-
29244481964
-
Low-cost microelectrode array with integrated heater for extracellular recording of cardiomyocyte cultures using commercial flexible printed circuit technology
-
DOI 10.1016/j.snb.2005.03.059, PII S0925400505003485
-
L. Giovangrandi, K.H. Gilchrist, R.H. Whittington, and G.T.A. Kovacs Low-cost microelectrode array with integrated heater for extracellular recording of cardiomyocyte cultures using commercial flexible printed circuit technology Sens. Actuators B 113 2006 545 554 (Pubitemid 41831329)
-
(2006)
Sensors and Actuators, B: Chemical
, vol.113
, Issue.1
, pp. 545-554
-
-
Giovangrandi, L.1
Gilchrist, K.H.2
Whittington, R.H.3
Kovacs, G.T.A.4
-
32
-
-
84937994376
-
The electrical properties of metal microelectrodes
-
D.A. Robinson The electrical properties of metal microelectrodes Proc. IEEE 56 1968 1065 1071
-
(1968)
Proc. IEEE
, vol.56
, pp. 1065-1071
-
-
Robinson, D.A.1
-
33
-
-
79958129043
-
Novel multi-sided, microelectrode arrays for implantable neural applications
-
J.P. Seymour, N.B. Langhals, D.J. Anderson, and D.R. Kipke Novel multi-sided, microelectrode arrays for implantable neural applications Biomed. Microdevices 13 2011 441 451
-
(2011)
Biomed. Microdevices
, vol.13
, pp. 441-451
-
-
Seymour, J.P.1
Langhals, N.B.2
Anderson, D.J.3
Kipke, D.R.4
-
35
-
-
0026772987
-
Differential properties of tetrodotoxin-sensitive and tetrodotoxin-resistant sodium channels in rat dorsal root ganglion neurons
-
M.L. Roy, and T. Narahashi Differential properties of tetrodotoxin-sensitive and tetrodotoxin-resistant sodium channels in rat dorsal root ganglion neurons J. Neurosci. 12 1992 2104 2111
-
(1992)
J. Neurosci.
, vol.12
, pp. 2104-2111
-
-
Roy, M.L.1
Narahashi, T.2
-
36
-
-
36249000115
-
Cell and protein compatibility of parylene-C surfaces
-
DOI 10.1021/la7017049
-
T.Y. Chang, V.G. Yadav, S. De Leo, A. Mohedas, B. Rajalingam, C.L. Chen, S. Selvarasah, M.R. Dokmeci, and A. Khademhosseini Cell and protein compatibility of parylene-C surfaces Langmuir 23 2007 11718 11725 (Pubitemid 350133020)
-
(2007)
Langmuir
, vol.23
, Issue.23
, pp. 11718-11725
-
-
Chang, T.Y.1
Yadav, V.G.2
De Leo, S.3
Mohedas, A.4
Rajalingam, B.5
Chen, C.-L.6
Selvarasah, S.7
Dokmeci, M.R.8
Khademhosseini, A.9
-
37
-
-
63849333349
-
Improved biocompatibility of parylene-c films prepared by chemical vapor deposition and the subsequent plasma treatment
-
J.S. Song, S. Lee, S.H. Jung, G.C. Cha, and M.S. Mun Improved biocompatibility of parylene-c films prepared by chemical vapor deposition and the subsequent plasma treatment J. Appl. Polym. Sci. 112 2009 3677 3685
-
(2009)
J. Appl. Polym. Sci.
, vol.112
, pp. 3677-3685
-
-
Song, J.S.1
Lee, S.2
Jung, S.H.3
Cha, G.C.4
Mun, M.S.5
|