Volumn 161, Issue 1, 2012, Pages 1030-1037

Disposable DNA biosensor based on thin-film gold electrodes for selective Salmonella detection

Author keywords

Electrochemical detection; Genosensor; MEMS technology; Ruthenium complex

Indexed keywords

COMPLEMENTARY SEQUENCES; DNA BIOSENSORS; ELECTROCHEMICAL BIOSENSOR; ELECTROCHEMICAL DETECTION; GENOSENSOR; GOLD ELECTRODES; INTERFERENTS; LYSTERIA; MEMS TECHNOLOGY; MICRO SYSTEMS TECHNOLOGIES; MULTI-ANALYTES; REDOX INDICATOR; RUTHENIUM COMPLEX; RUTHENIUM COMPLEXES; TARGET SEQUENCES;

EID: 84856211479     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.12.002     Document Type: Article
Times cited : (32)

References (23)
  • 1
    • 8044243016 scopus 로고
    • Mass production of biosensors
    • M.A. Icaza, and U. Bilitewski Mass production of biosensors Anal. Chem. 65 1993 525 531
    • (1993) Anal. Chem. , vol.65 , pp. 525-531
    • Icaza, M.A.1    Bilitewski, U.2
  • 2
    • 0001869364 scopus 로고    scopus 로고
    • Food safety and its impact on domestic and export markets
    • P. Davies Food safety and its impact on domestic and export markets Swine Health Product. 5 1997 13 20 (Pubitemid 127538017)
    • (1997) Journal of Swine Health and Production , vol.5 , Issue.1 , pp. 13-20
    • Davies, P.1
  • 3
    • 84856234239 scopus 로고    scopus 로고
    • Isolation and characterization of verocytotoxin-producing Escherichia coli O157 from slaughter pigs and poultry
    • E. De Boer, and F.J. Beumer Isolation and characterization of verocytotoxin-producing Escherichia coli O157 from slaughter pigs and poultry Int. Food Microbiol. 1-2 1999 119 130
    • (1999) Int. Food Microbiol. , vol.1-2 , pp. 119-130
    • De Boer, E.1    Beumer, F.J.2
  • 4
    • 0032745921 scopus 로고    scopus 로고
    • Biosensors for detection of pathogenic bacteria
    • DOI 10.1016/S0956-5663(99)00039-1, PII S0956566399000391
    • D. Invitski, I. Abbel-hamid, P. Atanasov, and E. Wilkins Biosensors for detection of pathogenic bacteria Biosens. Bioelectron. 14 1999 599 624 (Pubitemid 29528191)
    • (1999) Biosensors and Bioelectronics , vol.14 , Issue.7 , pp. 599-624
    • Ivnitski, D.1    Abdel-Hamid, I.2    Atanasov, P.3    Wilkins, E.4
  • 5
    • 0037333215 scopus 로고    scopus 로고
    • The EU and candidate countries: How to cope with food safety policies?
    • DOI 10.1016/S0956-7135(02)00112-3, PII S0956713502001123
    • D. Banati The EU and candidate countries: how to cope with food safety policies? Food Control 14 2003 89 93 (Pubitemid 36024512)
    • (2003) Food Control , vol.14 , Issue.2 , pp. 89-93
    • Banati, D.1
  • 6
    • 0037403839 scopus 로고    scopus 로고
    • Market analysis of biosensors for food safety
    • DOI 10.1016/S0956-5663(03)00009-5
    • E.C. Alocija, and S.M. Radke Market analysis of biosensors for food safety Biosens. Bioelectron. 18 2003 841 846 (Pubitemid 36428673)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.5-6 , pp. 841-846
    • Alocilja, E.C.1    Radke, S.M.2
  • 8
    • 47749103413 scopus 로고    scopus 로고
    • Recent advances in DNA sensors
    • DOI 10.1039/b803083a
    • S. Cosnier, and P. Mailley Recent advances in DNA sensors Analyst 133 2008 984 991 (Pubitemid 352033093)
    • (2008) Analyst , vol.133 , Issue.8 , pp. 984-991
    • Cosnier, S.1    Mailley, P.2
  • 9
    • 0042521069 scopus 로고    scopus 로고
    • Electrochemical behavior and detection of hepatitis B virus DNA PCR production at gold electrode
    • DOI 10.1016/S0956-5663(03)00121-0
    • Y.K. Ye, J.H. Zhao, F. Yan, Y.L. Zhu, and H.X. Ju Electrochemical behavior and detection of hepatitis B virus DNA PCR production at gold electrode Biosens. Bioelectron. 18 2003 1501 1508 (Pubitemid 36993656)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.12 , pp. 1501-1508
    • Ye, Y.K.1    Zhao, J.H.2    Yan, F.3    Zhu, Y.L.4    Ju, H.X.5
  • 10
    • 34250786075 scopus 로고    scopus 로고
    • Confirmative electric DNA array-based test for food poisoning Bacillus cereus
    • DOI 10.1016/j.mimet.2007.03.011, PII S0167701207000966
    • Y. Liu, B. Elsholz, S.-O. Enfors, and M. Gabig-Ciminska Confirmative electric DNA array-based test for food poisoning Bacillus cereus J. Microbiol. Methods 70 2007 55 64 (Pubitemid 46962770)
    • (2007) Journal of Microbiological Methods , vol.70 , Issue.1 , pp. 55-64
    • Liu, Y.1    Elsholz, B.2    Enfors, S.-O.3    Gabig-Ciminska, M.4
  • 11
    • 33847382787 scopus 로고    scopus 로고
    • In situ DNA amplification with magnetic primers for the electrochemical detection of food pathogens
    • DOI 10.1016/j.bios.2006.08.048, PII S0956566306004167, Selected Papers from the Ninth World Congress On Biosensors
    • A. Lermo, S. Campoy, J. Barbe, S. Hernandez, S. Alegret, and M.I. Pividori In situ DNA amplification with magnetic primers for the electrochemical detection of food pathogens Biosens. Bioelectron. 22 2007 2010 2017 (Pubitemid 46349638)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 2010-2017
    • Lermo, A.1    Campoy, S.2    Barbe, J.3    Hernandez, S.4    Alegret, S.5    Pividori, M.I.6
  • 13
    • 34247199573 scopus 로고    scopus 로고
    • A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment
    • DOI 10.1016/j.ab.2006.12.039, PII S0003269706009341
    • J. Yang, T. Yang, Y. Feng, and K. Jiao A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment Anal. Biochem. 365 2007 24 30 (Pubitemid 46617458)
    • (2007) Analytical Biochemistry , vol.365 , Issue.1 , pp. 24-30
    • Yang, J.1    Yang, T.2    Feng, Y.3    Jiao, K.4
  • 15
    • 33745854449 scopus 로고    scopus 로고
    • Development of disposable low density screen-printed electrode arrays for simultaneous electrochemical measurements of the hybridisation reaction
    • DOI 10.1016/j.jelechem.2006.04.015, PII S0022072806002397
    • S. Laschi, I. Palchetti, G. Marrazza, and M. Mascini Development of disposable low density screen-printed electrode arrays for simultaneous electrochemical measurements of the hybridisation reaction J. Electroanal. Chem. 593 2006 211 218 (Pubitemid 44036982)
    • (2006) Journal of Electroanalytical Chemistry , vol.593 , Issue.1-2 , pp. 211-218
    • Laschi, S.1    Palchetti, I.2    Marrazza, G.3    Mascini, M.4
  • 17
    • 84856218397 scopus 로고    scopus 로고
    • Characterization of lead dioxide electrodes prepared by thermal decomposition method on a stainless steel substrate and its electrochemical behaviour
    • L. Joon-Woo, C. Bae-Jin, and Y. In-Hyeong Characterization of lead dioxide electrodes prepared by thermal decomposition method on a stainless steel substrate and its electrochemical behaviour Anal. Sci. 17 2001 387 390
    • (2001) Anal. Sci. , vol.17 , pp. 387-390
    • Joon-Woo, L.1    Bae-Jin, C.2    In-Hyeong, Y.3
  • 18
    • 27744442425 scopus 로고    scopus 로고
    • Electrochemical deposition of 5,10,15,20-tetrakis-(4-sulphonatophenyl) porphyrin and its Co(II) derivative at a gold microelectrode array
    • DOI 10.1016/j.aca.2005.08.038, PII S0003267005014194
    • K.D. Wael, A. Adriaens, and E. Temmerman Electrochemical deposition of 5,10,15,20-tetrakis-(4-sulphonatophenyl) porphyrin and its Co(II) derivative at a gold microelectrode array Anal. Chim. Acta 554 2005 60 65 (Pubitemid 41586660)
    • (2005) Analytica Chimica Acta , vol.554 , Issue.1-2 , pp. 60-65
    • De Wael, K.1    Adriaens, A.2    Temmerman, E.3
  • 19
    • 0032310227 scopus 로고    scopus 로고
    • Performance of screen-printed carbon electrodes fabricated from different carbon inks
    • PII S0013468698000929
    • J. Wang, B. Tian, V.B. Nascimento, and L. Angnes Performance of screen-printed carbon electrodes fabricated from different carbon inks Electrochim. Acta 43 1998 3459 3465 (Pubitemid 128412580)
    • (1998) Electrochimica Acta , vol.43 , Issue.23 , pp. 3459-3465
    • Wang, J.1    Tian, B.2    Nascimento, V.B.3    Angnes, L.4
  • 21
    • 0343022327 scopus 로고    scopus 로고
    • Flexible amperometric transducers for biosensors based on a screen printed three electrode system
    • DOI 10.1016/S0022-0728(99)00491-X
    • A. Erlenkotter, M. Kottbus, and G.C. Chemnitius Flexible amperometric transducers for biosensors based on a screen printed three electrode systems J. Electroanal. Chem. 481 2000 82 94 (Pubitemid 30551983)
    • (2000) Journal of Electroanalytical Chemistry , vol.481 , Issue.1 , pp. 82-94
    • Erlenkotter, A.1    Kottbus, M.2    Chemnitius, G.-C.3
  • 22
    • 41149156576 scopus 로고    scopus 로고
    • Single-mismatch position-sensitive detection of DNA based on a bifunctional ruthenium complex
    • DOI 10.1021/ac071095r
    • T. García, M. Revenga-Parra, H.D. Abruña, F. Pariente, and E. Lorenzo Single-mismatch position-sensitive detection of DNA based on a bifunctional ruthenium complex Anal. Chem. 80 2008 77 84 (Pubitemid 351448407)
    • (2008) Analytical Chemistry , vol.80 , Issue.1 , pp. 77-84
    • Garcia, T.1    Revenga-Parra, M.2    Abruna, H.D.3    Pariente, F.4    Lorenzo, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.