메뉴 건너뛰기




Volumn 13, Issue SPEC.ISSUE, 2011, Pages 142-149

Antibody immobilization on conductive polymer coated nonwoven fibers for biosensors

Author keywords

Antibody immobilization; Electrochemical biosensor; Electrotextile; Fluorescence; Immunosensor

Indexed keywords

ANTIBODY IMMOBILIZATION; BLOCKING AGENTS; CAPTURE CAPABILITY; CONDUCTIVE FIBERS; CONDUCTIVE POLYMER; ELECTROCHEMICAL BIOSENSOR; ELECTROTEXTILE; FIBER MEMBRANES; FLUORESCENT REPORTER; FOOD-BORNE PATHOGENS; FUNCTIONALIZED; GLUTARALDEHYDE CROSS-LINKING; GLUTARALDEHYDES; IMMOBILIZATION METHOD; NON-WOVEN; PICOGREEN; SENSING FUNCTIONS; SINGLE COMPONENTS; SPECIFIC CAPTURE;

EID: 84856176711     PISSN: None     EISSN: 17265479     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (14)
  • 1
    • 51349096357 scopus 로고    scopus 로고
    • Development of functional nanofibrous membrane assemblies towards biological sensing
    • A. Senecal, J. Magnone, P. Marek and K. Senecal, Development of functional nanofibrous membrane assemblies towards biological sensing, Reactive & Functional Polymers, Vol. 68, Issue 10, 2008, pp. 1429-1434.
    • (2008) Reactive & Functional Polymers , vol.68 , Issue.10 , pp. 1429-1434
    • Senecal, A.1    Magnone, J.2    Marek, P.3    Senecal, K.4
  • 2
    • 79960298909 scopus 로고    scopus 로고
    • E-Textiles for Wearability: Review of Integration Technologies
    • April
    • M. Suh, E-Textiles for Wearability: Review of Integration Technologies, Textile World, April 2010.
    • (2010) Textile World
    • Suh, M.1
  • 3
    • 81555229441 scopus 로고    scopus 로고
    • High Surface Area Flexible Chemiresistive Biosensor by Oxidative Chemical Vapor Deposition
    • available online
    • D. Bhattacharyya, K. Senecal, P. Marek, A. Senecal, and K. Gleason, High Surface Area Flexible Chemiresistive Biosensor by Oxidative Chemical Vapor Deposition, Advanced Functional Materials, available online, 2011, pp. 1-10.
    • (2011) Advanced Functional Materials , pp. 1-10
    • Bhattacharyya, D.1    Senecal, K.2    Marek, P.3    Senecal, A.4    Gleason, K.5
  • 5
    • 0025921353 scopus 로고
    • Electrically conductive non-metallic textile coatings
    • R. Gregory, W. Kimbrell, and H. Kuhn, Electrically conductive non-metallic textile coatings, Journal of Industrial Textiles, Vol. 20, Issue 3, 1991, pp. 167-175.
    • (1991) Journal of Industrial Textiles , vol.20 , Issue.3 , pp. 167-175
    • Gregory, R.1    Kimbrell, W.2    Kuhn, H.3
  • 6
    • 0027596011 scopus 로고
    • Surface and adhesion properties of polypyrrole-coated textiles
    • C. Heisey, J. Wightman, E. Pittman, and H. Kuhn, Surface and adhesion properties of polypyrrole-coated textiles, Textile Research Journal, Vol. 63, Issue 5, 1993, pp. 247-256.
    • (1993) Textile Research Journal , vol.63 , Issue.5 , pp. 247-256
    • Heisey, C.1    Wightman, J.2    Pittman, E.3    Kuhn, H.4
  • 8
    • 0027578904 scopus 로고
    • Properties and applications of conductive textiles
    • H. Kuhn, W. Kimbrell, J. Fowler, and C. Barry, Properties and applications of conductive textiles, Synthetic Metals, Vol. 57, Issue 1, 1993, pp. 3707-3712.
    • (1993) Synthetic Metals , vol.57 , Issue.1 , pp. 3707-3712
    • Kuhn, H.1    Kimbrell, W.2    Fowler, J.3    Barry, C.4
  • 10
    • 0033333834 scopus 로고    scopus 로고
    • Monitoring antibody-antigen reactions at conducting polymer-based immunosensors using impedance spectroscopy
    • A. Sargent and O. Sadik, Monitoring antibody-antigen reactions at conducting polymer-based immunosensors using impedance spectroscopy, Electrochemica Acta, Vol. 44, Issue 26, 1999, pp. 4667-4675.
    • (1999) Electrochemica Acta , vol.44 , Issue.26 , pp. 4667-4675
    • Sargent, A.1    Sadik, O.2
  • 11
    • 33751072399 scopus 로고    scopus 로고
    • Biomolecular immobilization on conducting polymers for biosensing applications
    • T. Ahuja, I. Mir, D. Kumar and Rajesh, Biomolecular immobilization on conducting polymers for biosensing applications, Biomaterials, Vol. 28, Issue 5, 2007, pp. 791-805.
    • (2007) Biomaterials , vol.28 , Issue.5 , pp. 791-805
    • Ahuja, T.1    Mir, I.2    Kumar, D.3    Rajesh4
  • 13
    • 3042803565 scopus 로고    scopus 로고
    • A Disposable Biosensor for Pathogen Detection in Fresh Produce Samples
    • Z. Muhammad-Tahir and E. Alocilja, A Disposable Biosensor for Pathogen Detection in Fresh Produce Samples, Biosystems Engineering Journal, Vol. 88, Issue 2, 2004, pp. 145-151.
    • (2004) Biosystems Engineering Journal , vol.88 , Issue.2 , pp. 145-151
    • Muhammad-Tahir, Z.1    Alocilja, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.