메뉴 건너뛰기




Volumn 3, Issue , 2011, Pages 56-59

Antibody immobilization on conductive polymer coated nonwoven fibers for biosensors

Author keywords

Antibody; Biosensor; Electrotextile; Fluorescence; Immobilization

Indexed keywords

ANTIBODY IMMOBILIZATION; CAPTURE CAPABILITY; CONDUCTIVE FIBERS; CONDUCTIVE POLYMER; ELECTROCHEMICAL BIOSENSOR; ELECTROTEXTILE; FIBER MEMBRANES; FOOD PATHOGENS; FUNCTIONALIZED; GLUTERALDEHYDES; NON-WOVEN; SENSING FUNCTIONS; SINGLE COMPONENTS; SPECIFIC CAPTURE; US ARMY;

EID: 81455139991     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 51349096357 scopus 로고    scopus 로고
    • Development of functional nanofibrous membrane assemblies towards biological sensing
    • A. Senecal, J. Magnone, P. Marek and K. Senecal, "Development of functional nanofibrous membrane assemblies towards biological sensing," Reactive & Functional Polymers, 68, 1429-1434, 2008.
    • (2008) Reactive & Functional Polymers , vol.68 , pp. 1429-1434
    • Senecal, A.1    Magnone, J.2    Marek, P.3    Senecal, K.4
  • 2
    • 79960298909 scopus 로고    scopus 로고
    • E-Textiles for Wearability: Review of Integration Technologies
    • M. Suh, "E-Textiles For Wearability: Review Of Integration Technologies," Textile World, 2010.
    • (2010) Textile World
    • Suh, M.1
  • 4
    • 0025921353 scopus 로고
    • Electrically conductive non-metallic textile coatings
    • R.V. Gregory, W.C. Kimbrell, and H.H. Kuhn, "Electrically conductive non-metallic textile coatings." Journal of Coated Fabrics, 20, 167-175, 1991. (Pubitemid 21731180)
    • (1991) Journal of Coated Fabrics , vol.20 , pp. 167-175
    • Gregory, R.V.1    Kimbrell, W.C.2    Kuhn, H.H.3
  • 6
    • 33644608119 scopus 로고
    • Method for making electrically conductive textile materials
    • United States Patent 4,877,646
    • H.H. Kuhn and W.C. Kimbrell, "Method for making electrically conductive textile materials," United States Patent 4,877,646, 1989.
    • (1989)
    • Kuhn, H.H.1    Kimbrell, W.C.2
  • 9
    • 0033333834 scopus 로고    scopus 로고
    • Monitoring antibody-antigen reactions at conducting polymer-based immunosensors using impedance spectroscopy
    • A. Sargent and O.A. Sadik, "Monitoring antibody-antigen reactions at conducting polymer-based immunosensors using impedance spectroscopy," Electrochemica Acta, 44, 4667-4675, 1999. (Pubitemid 30506159)
    • (1999) Electrochimica Acta , vol.44 , Issue.26 , pp. 4667-4675
    • Sargent, A.1    Sadik, O.A.2
  • 10
    • 33751072399 scopus 로고    scopus 로고
    • Biomolecular immobilization on conducting polymers for biosensing applications
    • T. Ahuja, I.A. Mir, D. Kumar and Rajesh, "Biomolecular immobilization on conducting polymers for biosensing applications," Biomaterials, 28, 791-805, 2007.
    • (2007) Biomaterials , vol.28 , pp. 791-805
    • Ahuja, T.1    Mir, I.A.2    Kumar, D.3    Rajesh4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.