-
1
-
-
0025236887
-
DIE BEDEUTUNG DES ENTNAHMEORTES BEI DER BESTIMMUNG VON LOKALANAESTHETIKAKONZENTRATIONEN IM PLASMA AM BEISPIEL VON BUPIVACAIN 0.75 %
-
Bachmann MB, Biscoping J, Adams HA, et al. The significance of the sampling site in the determination of plasma levels of local anesthetics using 0.75% bupivacaine as an example. Reg Anaesth. 1990;13:16-20. (Pubitemid 20088037)
-
(1990)
Anaesthesist - Regional Anaesthesie
, vol.13
, Issue.1
, pp. 16-20
-
-
Bachmann, B.-M.1
Biscoping, J.2
Adams, H.A.3
Menges, T.4
Krumholz, W.5
Hempelmann, G.6
-
2
-
-
0035218036
-
Quantification of doxorubicin in plasma - A comparative study of capillary and venous blood sampling
-
DOI 10.1097/00001813-200111000-00011
-
Palm C, Bjork O, Bjorkholm M, et al. Quantification of doxorubicin in plasma-a comparative study of capillary and venous blood sampling. Anticancer Drugs. 2001;12:859-864. (Pubitemid 33151536)
-
(2001)
Anti-Cancer Drugs
, vol.12
, Issue.10
, pp. 859-864
-
-
Palm, C.1
Bjork, O.2
Bjorkholm, M.3
Eksborg, S.4
-
3
-
-
0031781226
-
Central venous catheters versus peripheral veins for sampling blood levels of commonly used drugs
-
Shulman RJ, Ou C, Reed T, et al. Central venous catheters versus peripheral veins for sampling blood levels of commonly used drugs. J Parenter Enteral Nutr. 1998;22:234-237. (Pubitemid 28307587)
-
(1998)
Journal of Parenteral and Enteral Nutrition
, vol.22
, Issue.4
, pp. 234-237
-
-
Shulman, R.J.1
Ching, O.U.2
Reed, T.3
Gardner, P.4
-
4
-
-
0033025544
-
Sampling technique from central venous catheters proves critical for pharmacokinetic studies
-
DOI 10.1097/00007691-199902000-00016
-
Huitema AD, Holtkamp M, Tibben MM, et al. Sampling technique from central venous catheters proves critical for pharmacokinetic studies. Ther Drug Monit. 1999;21:102-104. (Pubitemid 29077462)
-
(1999)
Therapeutic Drug Monitoring
, vol.21
, Issue.1
, pp. 102-104
-
-
Huitema, A.D.R.1
Holtkamp, M.2
Tibben, M.M.3
Rodenhuis, S.4
Beijnen, J.H.5
-
5
-
-
0024512639
-
Therapeutic monitoring of cyclosporine following pediatric bone marrow transplantation: Problems with sampling from silicone central venous lines
-
Leson CL, Bryson SM, Giesbrecht EE, et al. Therapeutic monitoring of cyclosporine following pediatric bone marrow transplantation: problems with sampling from silicone central venous lines. DICP. 1989;23:300-303. (Pubitemid 19102682)
-
(1989)
DICP, Annals of Pharmacotherapy
, vol.23
, Issue.4
, pp. 300-303
-
-
Leson, C.L.1
Bryson, S.M.2
Giesbrecht, E.E.3
Saunders, E.F.4
-
6
-
-
0030770868
-
It's in the bag: Drug absorption by drug-delivery sysems
-
DOI 10.1097/00004714-199710000-00001
-
Shader RI, Greenblatt DJ. It's in the bag: drug absorption by drug-delivery systems. J Clin Psychopharmacol. 1997;17:339-340. (Pubitemid 27414387)
-
(1997)
Journal of Clinical Psychopharmacology
, vol.17
, Issue.5
, pp. 339-340
-
-
Shader, R.I.1
Greenblatt, D.J.2
-
9
-
-
8444251813
-
Comparing two methods to obtain blood specimens from pediatric central venous catheters
-
DOI 10.1177/1043454204269604
-
Barton SJ, Chase T, Latham B, et al. Comparing two methods to obtain blood specimens from pediatric central venous catheters. J Pediatr Oncol Nurs. 2004;21:320-326. (Pubitemid 39486328)
-
(2004)
Journal of Pediatric Oncology Nursing
, vol.21
, Issue.6
, pp. 320-326
-
-
Barton, S.J.1
Chase, T.2
Latham, B.3
Rayens, M.K.4
-
10
-
-
0024005830
-
Comparison of the mixing and reinfusion methods of drawing blood from a Hickman catheter
-
MacGeorte L, Steeves L, Steeves RH. Comparison of the mixing and reinfusion methods of drawing blood from a Hickman catheter. Oncol Nurs Forum. 1988;15:335-338.
-
(1988)
Oncol Nurs Forum.
, vol.15
, pp. 335-338
-
-
MacGeorte, L.1
Steeves, L.2
Steeves, R.H.3
-
11
-
-
0026000582
-
Effect of monitoring drug concentrations through lines used to administer the drugs: An in vitro study
-
Wanwimolruk S, Murphy JE. Effect of monitoring drug concentrations through lines used to administer the drugs: an in vitro study. Ther Drug Monit. 1991;13:443-447.
-
(1991)
Ther Drug Monit.
, vol.13
, pp. 443-447
-
-
Wanwimolruk, S.1
Murphy, J.E.2
-
12
-
-
34248173902
-
A study to determine the minimum volume of blood necessary to be discarded from a central venous catheter before a valid sample is obtained in children with cancer
-
DOI 10.1002/pbc.20873
-
Cole M, Price L, Parry A, et al. A study to determine the minimum volume of blood necessary to be discarded from a central venous catheter before a valid sample is obtained in children with cancer. Pediatr Blood Cancer. 2007;48:687-695. (Pubitemid 46717616)
-
(2007)
Pediatric Blood and Cancer
, vol.48
, Issue.7
, pp. 687-695
-
-
Cole, M.1
Price, L.2
Parry, A.3
Picton, S.4
Waters, F.5
Marshall, S.6
Goran, C.7
Parnham, A.8
Wastell, H.9
Reid, M.M.10
Pearson, A.D.J.11
Boddy, A.V.12
Veal, G.J.13
-
13
-
-
18344372556
-
Blood sampling for biochemical analysis from central venous catheters: Minimizing the volume of discarded blood
-
DOI 10.1515/CCLM.2002.026
-
Odum L, Drenck NE. Blood sampling for biochemical analysis from central venous catheters: minimizing the volume of discarded blood. Clin Chem Lab Med. 2002;40:152-155. (Pubitemid 34257829)
-
(2002)
Clinical Chemistry and Laboratory Medicine
, vol.40
, Issue.2
, pp. 152-155
-
-
Odum, L.1
Drenck, N.-E.2
-
14
-
-
0019416260
-
Adriamycin distribution in plasma and blood cells of cancer patients with altered hematocrit
-
DOI 10.1016/0014-2964(81)90293-0
-
Piazza E, Broggini M, Trabattoni A, et al. Adriamycin distribution in plasma and blood cells of cancer patients with altered hematocrit. Eur J Cancer Clin Oncol. 1981;17:1089-1096. (Pubitemid 11030521)
-
(1981)
European Journal of Cancer and Clinical Oncology
, vol.17
, Issue.10
, pp. 1089-1096
-
-
Piazza, E.1
Broggini, M.2
Trabattoni, A.3
-
15
-
-
0019972115
-
Concomitant adsorption and stability of some anthracycline antibiotics
-
DOI 10.1002/jps.2600711011
-
Tomlinson E, Malspeis L. Concomitant adsorption and stability of some anthracycline antibiotics. J Pharm Sci. 1982;71:1121-1125. (Pubitemid 12032676)
-
(1982)
Journal of Pharmaceutical Sciences
, vol.71
, Issue.10
, pp. 1121-1125
-
-
Tomlinson, E.1
Malspeis, L.2
-
16
-
-
0031772912
-
Therapeutic drug monitoring of doxorubicin in paediatric oncology using capillary electrophoresis
-
Hempel G, Schulze-Westhoff P, Flege S, et al. Therapeutic drug monitoring of doxorubicin in paediatric oncology using capillary electrophoresis. Electrophoresis. 1998;19:2939-2943. (Pubitemid 28559922)
-
(1998)
Electrophoresis
, vol.19
, Issue.16-17
, pp. 2939-2943
-
-
Hempel, G.1
Schulze-Westhoff, P.2
Flege, S.3
Laubrock, N.4
Boos, J.5
-
17
-
-
72049089584
-
Development and validation of a liquid chromatographic method for the simultaneous determination of four anthracyclines and their respective 13-S-dihydro metabolites in plasma and saliva
-
Maudens KE, Stove CP, Cocquyt VF, et al. Development and validation of a liquid chromatographic method for the simultaneous determination of four anthracyclines and their respective 13-S-dihydro metabolites in plasma and saliva. J Chromatogr B Analyt Technol Biomed Life Sci. 2009;877:3907-3915.
-
(2009)
J Chromatogr B Analyt Technol Biomed Life Sci.
, vol.877
, pp. 3907-3915
-
-
Maudens, K.E.1
Stove, C.P.2
Cocquyt, V.F.3
-
18
-
-
0033211452
-
Venipuncture versus central venous access: A comparison of methotrexate levels in pediatric leukemia patients
-
Cash M, Schafhauser B, Byers JF. Venipuncture versus central venous access: a comparison of methotrexate levels in pediatric leukemia patients. J Pediatr Oncol Nurs. 1999;16:189-193.
-
(1999)
J Pediatr Oncol Nurs.
, vol.16
, pp. 189-193
-
-
Cash, M.1
Schafhauser, B.2
Byers, J.F.3
-
19
-
-
34547679875
-
Therapeutic drug monitoring of methotrexate on the pediatric oncology ward: Can blood sampling from central venous accesses substitute for capillary finger punctures?
-
DOI 10.1097/FTD.0b013e318063e5e5, PII 0000769120070800000010
-
Ritzmo C, Albertioni F, Cosic K, et al. Therapeutic drug monitoring of methotrexate on the pediatric oncology ward: can blood sampling from central venous accesses substitute for capillary finger punctures? Ther Drug Monit. 2007;29:447-451. (Pubitemid 47220462)
-
(2007)
Therapeutic Drug Monitoring
, vol.29
, Issue.4
, pp. 447-451
-
-
Ritzmo, C.1
Albertioni, F.2
Cosic, K.3
Soderhall, S.4
Eksborg, S.5
-
20
-
-
0036879903
-
Contamination levels in blood samples drawn from the injection intravenous line
-
DOI 10.1016/S1536-1632(02)00121-X, PII S153616320200121X
-
Ponto LL, Graham MM, Richmond JC, et al. Contamination levels in blood samples drawn from the injection intravenous line. Mol Imaging Bio. 2002;4:410-414. (Pubitemid 36221808)
-
(2002)
Molecular Imaging and Biology
, vol.4
, Issue.6
, pp. 410-414
-
-
Boles Ponto, L.L.1
Graham, M.M.2
Richmond, J.C.3
Ward, C.A.4
Clermont, D.A.5
Schmitt, B.A.6
Clark, J.7
Conklin, A.8
Weldon, L.9
Watkins, G.L.10
Madsen, M.T.11
Hichwa, R.D.12
-
21
-
-
0025942354
-
Elevated phenytoin concentration caused by sampling through the drug-administration catheter
-
Murphy JE, Ward ES. Elevated phenytoin concentration caused by sampling through the drug-administration catheter. Pharmacotherapy. 1991;11:348-350.
-
(1991)
Pharmacotherapy
, vol.11
, pp. 348-350
-
-
Murphy, J.E.1
Ward, E.S.2
-
22
-
-
38749109322
-
Misleading tacrolimus concentration value in blood taken from a catheter used for tacrolimus administration
-
DOI 10.2146/ajhp070054
-
Grouzmann E, Buclin T, Biollaz J. Misleading tacrolimus concentration value in blood taken from a catheter used for tacrolimus administration. Am J Health Syst Pharm. 2008;65:226-228. (Pubitemid 351220772)
-
(2008)
American Journal of Health-System Pharmacy
, vol.65
, Issue.3
, pp. 226-228
-
-
Grouzmann, E.1
Buclin, T.2
Biollaz, J.3
-
23
-
-
64249172370
-
Accuracy of tobramycin levels obtained from central venous access devices in patients with cystic fibrosis is technique dependent
-
quiz 468-469
-
Mogayzel PJ, Pierce E, Mills J, et al. Accuracy of tobramycin levels obtained from central venous access devices in patients with cystic fibrosis is technique dependent. Pediatr Nurs. 2008;34:464-468; quiz 468-469.
-
(2008)
Pediatr Nurs.
, vol.34
, pp. 464-468
-
-
Mogayzel, P.J.1
Pierce, E.2
Mills, J.3
-
24
-
-
78649271911
-
Falsely elevated vancomycin plasma concentrations sampled from central venous implantable catheters (portacaths)
-
Wright DF, Al-Sallami HS, Jackson PM, et al. Falsely elevated vancomycin plasma concentrations sampled from central venous implantable catheters (portacaths). Br J Clin Pharmacol. 2010;70:769-772.
-
(2010)
Br J Clin Pharmacol.
, vol.70
, pp. 769-772
-
-
Wright, D.F.1
Al-Sallami, H.S.2
Jackson, P.M.3
-
25
-
-
4544264114
-
Antibiotic sampling from central venous catheters versus peripheral veins
-
McBeth CL, McDonald RJ, Hodge MB. Antibiotic sampling from central venous catheters versus peripheral veins. Pediatr Nurs. 2004;30:200-202.
-
(2004)
Pediatr Nurs.
, vol.30
, pp. 200-202
-
-
McBeth, C.L.1
McDonald, R.J.2
Hodge, M.B.3
-
26
-
-
33947178412
-
Extent of agreement in gentamicin concentration between serum that is drawn peripherally and from central venous catheters
-
Boodhan S, Maloney AM, Dupuis LL. Extent of agreement in gentamicin concentration between serum that is drawn peripherally and from central venous catheters. Pediatrics. 2006;118:1650-1656.
-
(2006)
Pediatrics
, vol.118
, pp. 1650-1656
-
-
Boodhan, S.1
Maloney, A.M.2
Dupuis, L.L.3
-
27
-
-
78650300120
-
Approaches to clear residual chemotherapeutics from indwelling catheters in children with cancer
-
Skolnik JM, Zhang AY, Barrett JS. Approaches to clear residual chemotherapeutics from indwelling catheters in children with cancer. Ther Drug Monit. 2010;32:741-748.
-
(2010)
Ther Drug Monit.
, vol.32
, pp. 741-748
-
-
Skolnik, J.M.1
Zhang, A.Y.2
Barrett, J.S.3
|