-
1
-
-
84856015722
-
-
United States Food and Drug Administration Accessed October 1, 2011
-
United States Food and Drug Administration Removing retrievable inferior vena cava filters: initial communication http://www.fda.gov/MedicalDevices/ Safety/AlertsandNotices/ucm221676.htm Accessed October 1, 2011
-
Removing Retrievable Inferior Vena Cava Filters: Initial Communication
-
-
-
2
-
-
78149393576
-
Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade
-
W. Nicholson, W.J. Nicholson, P. Tolerico Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade Arch Intern Med 170 2010 1827 1831
-
(2010)
Arch Intern Med
, vol.170
, pp. 1827-1831
-
-
Nicholson, W.1
Nicholson, W.J.2
Tolerico, P.3
-
3
-
-
33744728279
-
"Recovery™" vena cava filter: Experience in 96 patients
-
DOI 10.1007/s00270-005-0271-1
-
S.P. Kalva, C.A. Athanasoulis, C.M. Fan "Recovery" vena cava filter: experience in 96 patients Cardiovasc Intervent Radiol 29 2006 559 564 (Pubitemid 43822998)
-
(2006)
CardioVascular and Interventional Radiology
, vol.29
, Issue.4
, pp. 559-564
-
-
Kalva, S.P.1
Athanasoulis, C.A.2
Fan, C.-M.3
Curvelo, M.4
Geller, S.C.5
Greenfield, A.J.6
Waltman, A.C.7
Wicky, S.8
-
4
-
-
57749118727
-
Bard Recovery filter: Evaluation and management of vena cava limb perforation, fracture, and migration
-
J.E. Hull, S.W. Robertson Bard Recovery filter: evaluation and management of vena cava limb perforation, fracture, and migration J Vasc Interv Radiol 20 2009 52 60
-
(2009)
J Vasc Interv Radiol
, vol.20
, pp. 52-60
-
-
Hull, J.E.1
Robertson, S.W.2
-
5
-
-
33744769148
-
Right ventricular migration of a Recovery IVC filter's fractured wire with subsequent pericardial tamponade
-
DOI 10.1007/s00270-005-0136-7
-
I. Saeed, M. Garcia, K. McNicholas Right ventricular migration of a recovery IVC filter's fractured wire with subsequent pericardial tamponade Cardiovasc Intervent Radiol 29 2006 685 686 (Pubitemid 43823022)
-
(2006)
CardioVascular and Interventional Radiology
, vol.29
, Issue.4
, pp. 685-686
-
-
Saeed, I.1
Garcia, M.2
McNicholas, K.3
-
6
-
-
45549088122
-
Retrieval of the recovery filter after arm perforation, fracture, and migration to the right ventricle
-
J.E. Hull, J. Han, G.M. Giessel Retrieval of the recovery filter after arm perforation, fracture, and migration to the right ventricle J Vasc Interv Radiol 19 2008 1107 1111
-
(2008)
J Vasc Interv Radiol
, vol.19
, pp. 1107-1111
-
-
Hull, J.E.1
Han, J.2
Giessel, G.M.3
-
7
-
-
77955716532
-
Fragmentation, embolization, and left ventricular perforation of a recovery filter
-
B. Desjardins, S.H. Kamath, D. Williams Fragmentation, embolization, and left ventricular perforation of a recovery filter J Vasc Interv Radiol 21 2010 1293 1296
-
(2010)
J Vasc Interv Radiol
, vol.21
, pp. 1293-1296
-
-
Desjardins, B.1
Kamath, S.H.2
Williams, D.3
-
8
-
-
27744550211
-
Recommended reporting standards for vena caval filter placement and patient follow-up
-
Vena Caval Filter Consensus Conference
-
Vena Caval Filter Consensus Conference Recommended reporting standards for vena caval filter placement and patient follow-up J Vasc Interv Radiol 14 Suppl 2003 S427 S432
-
(2003)
J Vasc Interv Radiol
, vol.14
, Issue.SUPPL.
-
-
-
9
-
-
16244393091
-
Reporting standards for inferior vena caval filter placement and patient follow-up: Supplement for temporary and retrievable/optional filters
-
DOI 10.1097/01.RVI.0000156096.22103.18
-
S.F. Millward, C.J. Grassi, T.B. Kinney Technology Assessment Committee of the Society of Interventional Radiology Reporting standards for inferior vena caval filter placement and patient follow-up: supplement for temporary and retrievable/optional filters J Vasc Interv Radiol 16 2005 441 443 (Pubitemid 40464184)
-
(2005)
Journal of Vascular and Interventional Radiology
, vol.16
, Issue.4
, pp. 441-443
-
-
Millward, S.F.1
Grassi, C.J.2
Kinney, T.B.3
Kundu, S.4
Becker, G.J.5
Cardella, J.F.6
Martin, L.G.7
Silberzweig, J.E.8
Sacks, D.9
-
11
-
-
79957567667
-
Retrievability and device-related complications of the G2 filter: A retrospective study of 139 filter retrievals
-
X. Zhu, M.D. Tam, J. Bartholomew, J.S. Newman, M.J. Sands, W. Wang Retrievability and device-related complications of the G2 filter: a retrospective study of 139 filter retrievals J Vasc Interv Radiol 22 2011 806 812
-
(2011)
J Vasc Interv Radiol
, vol.22
, pp. 806-812
-
-
Zhu, X.1
Tam, M.D.2
Bartholomew, J.3
Newman, J.S.4
Sands, M.J.5
Wang, W.6
-
12
-
-
84856017140
-
Complications of the Bard Recovery filter and their effect on attempted retrieval in 107 patients
-
M.D. Tam, X. Zhu, G. McLennan Complications of the Bard Recovery filter and their effect on attempted retrieval in 107 patients J Vasc Interv Radiol 21 Suppl 2010 S3
-
(2010)
J Vasc Interv Radiol
, vol.21
, Issue.SUPPL.
, pp. 3
-
-
Tam, M.D.1
Zhu, X.2
McLennan, G.3
-
13
-
-
39849091796
-
Sudden cardiac death caused by migration of a TrapEase inferior vena cava filter: Case report and review of the literature
-
DOI 10.1002/clc.20156
-
B. Haddadian, F. Shaikh, M. Djelmami-Hani, Y. Shalev Sudden cardiac death caused by migration of a TrapEase inferior vena cava filter: case report and review of the literature Clin Cardiol 31 2008 84 87 (Pubitemid 351317218)
-
(2008)
Clinical Cardiology
, vol.31
, Issue.2
, pp. 84-87
-
-
Haddadian, B.1
Shaikh, F.2
Djelmami-Hani, M.3
Shalev, Y.4
|