메뉴 건너뛰기




Volumn 170, Issue 20, 2010, Pages 1827-1831

Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; ECHOCARDIOGRAPHY; END ORGAN FRAGMENT EMBOLIZATION; FEMALE; FLUOROSCOPY; HEART INJURY; HEART PERFORATION; HEART TAMPONADE; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; PERICARDIAL EFFUSION; POSTOPERATIVE COMPLICATION; PREVALENCE; PRIORITY JOURNAL; SUDDEN DEATH; THORAX PAIN; VENA CAVA FILTER; VENA CAVA FILTER FRACTURE;

EID: 78149393576     PISSN: 00039926     EISSN: 15383679     Source Type: Journal    
DOI: 10.1001/archinternmed.2010.316     Document Type: Article
Times cited : (183)

References (9)
  • 2
    • 0027312890 scopus 로고
    • Percutaneous inferior vena caval filters: Follow-up of seven designs in 320 patients
    • Ferris EJ, McCowan TC, Carver DK, McFarland DR. Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients. Radiology. 1993;188(3):851-856.
    • (1993) Radiology , vol.188 , Issue.3 , pp. 851-856
    • Ferris, E.J.1    McCowan, T.C.2    Carver, D.K.3    McFarland, D.R.4
  • 3
    • 0031612487 scopus 로고    scopus 로고
    • Long-term results of the Simon nitinol inferior vena cava filter
    • Poletti PA, Becker CD, Prina L, et al. Long-term results of the Simon nitinol inferior vena cava filter. Eur Radiol. 1998;8(2):289-294.
    • (1998) Eur Radiol , vol.8 , Issue.2 , pp. 289-294
    • Poletti, P.A.1    Becker, C.D.2    Prina, L.3
  • 4
    • 45449120115 scopus 로고    scopus 로고
    • Fractured inferior vena cava filter strut presenting as a penetrating foreign body in the right ventricle: Report of a case
    • Kumar SP, Mahtabifard A, Young JN. Fractured inferior vena cava filter strut presenting as a penetrating foreign body in the right ventricle: report of a case. J Card Surg. 2008;23(4):378-381.
    • (2008) J Card Surg , vol.23 , Issue.4 , pp. 378-381
    • Kumar, S.P.1    Mahtabifard, A.2    Young, J.N.3
  • 5
    • 33744769148 scopus 로고    scopus 로고
    • Right ventricular migration of a Recovery IVC filter's fractured wire with subsequent pericardial tamponade
    • DOI 10.1007/s00270-005-0136-7
    • Saeed I, Garcia M, McNicholas K. Right ventricular migration of a recovery IVC filter's fractured wire with subsequent pericardial tamponade. Cardiovasc Intervent Radiol. 2006;29(4):685-686. (Pubitemid 43823022)
    • (2006) CardioVascular and Interventional Radiology , vol.29 , Issue.4 , pp. 685-686
    • Saeed, I.1    Garcia, M.2    McNicholas, K.3
  • 6
    • 57749118727 scopus 로고    scopus 로고
    • Bard Recovery filter: Evaluation and management of vena cava limb perforation, fracture, and migration
    • Hull JE, Robertson SW.Bard Recovery filter: evaluation and management of vena cava limb perforation, fracture, and migration. J Vasc Interv Radiol. 2009;20(1):52-60.
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.1 , pp. 52-60
    • Hull, J.E.1    Robertson, S.W.2
  • 7
    • 69249229545 scopus 로고    scopus 로고
    • Removal of the G2 filter: Differences between implantation times greater and less than 180 days
    • Lynch FC, Kekulawela S. Removal of the G2 filter: differences between implantation times greater and less than 180 days. J Vasc Interv Radiol. 2009;20(9):1200-1209.
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.9 , pp. 1200-1209
    • Lynch, F.C.1    Kekulawela, S.2