메뉴 건너뛰기




Volumn , Issue , 2011, Pages 399-402

New generation of medical implants: Metallic biodegradable coronary stent

Author keywords

316L stainless steel; Coronary stent; degradable metal; iron; laser cutting; magnesium; powder metallurgy; toxicity

Indexed keywords

316 L STAINLESS STEEL; BIODEGRADABLE STENTS; CONSTITUTIVE MATERIALS; CORONARY ARTERIES; CORONARY STENTS; DEGRADATION BEHAVIOR; DEGRADATION RATE; FIBROBLAST CELLS; INNOVATIVE APPROACHES; LASER CUTTING; MECHANICAL PERFORMANCE; MEDICAL IMPLANTS; METAL ALLOYS; PHYSICAL AND MECHANICAL PROPERTIES; POWDER SINTERING; PURE IRON;

EID: 84855978513     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICICI-BME.2011.6108635     Document Type: Conference Paper
Times cited : (9)

References (24)
  • 1
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal - Results 6-18 months after implantation into New Zealand white rabbits
    • Peuster M, Wohlsein P, Brugmann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits. Heart 2001; 86: 563-569. (Pubitemid 32999872)
    • (2001) Heart , vol.86 , Issue.5 , pp. 563-569
    • Peuster, M.1    Wohlsein, P.2    Brugmann, M.3    Ehlerding, M.4    Seidler, K.5    Fink, C.6    Brauer, H.7    Fischer, A.8    Hausdorf, G.9
  • 2
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • Heublein B, Rohde R, Kaese Y, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology? Heart 2003; 89: 651-656. (Pubitemid 36606211)
    • (2003) Heart , vol.89 , Issue.6 , pp. 651-656
    • Heublein, B.1    Rohde, R.2    Kaese, V.3    Niemeyer, M.4    Hartung, W.5    Haverich, A.6
  • 4
    • 77951915002 scopus 로고    scopus 로고
    • Degradable metallic biomaterials: The concept, current developments and future directions
    • Hermawan H, Mantovani D. Degradable metallic biomaterials: The concept, current developments and future directions. Minerva Biotecnol 2009;21 :207 -216
    • (2009) Minerva Biotecnol , vol.21 , pp. 207-216
    • Hermawan, H.1    Mantovani, D.2
  • 9
    • 12144250767 scopus 로고    scopus 로고
    • Preliminary results after application of absorbable metal stents in patients with critical limb ischemia
    • DOI 10.1583/04-1349R.1
    • Peeters P, Bosiers M, Yerbist J, Deloose K, Heublein B. Preliminary results after application of absorbable metal stents in patients with critical limb ischemia. J Endovasc Ther 2005; 12: 1-5. (Pubitemid 40229382)
    • (2005) Journal of Endovascular Therapy , vol.12 , Issue.1 , pp. 1-5
    • Peeters, P.1    Bosiers, M.2    Verbist, J.3    Deloose, K.4    Heublein, B.5
  • 11
    • 38949193830 scopus 로고    scopus 로고
    • Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials
    • DOI 10.1016/j.actbio.2007.09.012, PII S1742706107001602
    • Levesque J, Hermawan H, Dube D, Mantovani D. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials. Acta Biomater 2008; 4: 284-295. (Pubitemid 351218099)
    • (2008) Acta Biomaterialia , vol.4 , Issue.2 , pp. 284-295
    • Levesque, J.1    Hermawan, H.2    Dube, D.3    Mantovani, D.4
  • 13
    • 49649120694 scopus 로고    scopus 로고
    • Ironmanganese: New class of degradable metallic biomaterials prepared by powder metallurgy
    • Hermawan H, Alamdari H, Mantovani D, Dube D. Ironmanganese: New class of degradable metallic biomaterials prepared by powder metallurgy. Powder Metall 2008; 51: 38- 45.
    • (2008) Powder Metall , vol.51 , pp. 38-45
    • Hermawan, H.1    Alamdari, H.2    Mantovani, D.3    Dube, D.4
  • 15
    • 77956768974 scopus 로고    scopus 로고
    • Metallic stent which is degradable in vivo
    • Heublein B, Hausdorf G. Metallic stent which is degradable in vivo. EPO 2002: EP1270023.
    • (2002) EPO
    • Heublein, B.1    Hausdorf, G.2
  • 16
    • 77954673809 scopus 로고    scopus 로고
    • Developments in metallic biodegradable stents
    • Hermawan H, Dube D, Mantovani D. Developments in metallic biodegradable stents. Acta Biomater 2010;6:1693- 1697.
    • (2010) Acta Biomater , vol.6 , pp. 1693-1697
    • Hermawan, H.1    Dube, D.2    Mantovani, D.3
  • 17
    • 77649201086 scopus 로고    scopus 로고
    • Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents
    • Hermawan H, Dube D, Mantovani D. Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents. J Biomed Mater Res 201 0;93A: I-II.
    • (2010) J Biomed Mater Res , vol.93 A
    • Hermawan, H.1    Dube, D.2    Mantovani, D.3
  • 19
    • 77954684596 scopus 로고    scopus 로고
    • FeMn alloys for metallic biodegradable stents: Degradation and cell viability studies
    • Hermawan H, Purnama A, Dube D, Couet J, Mantovani D. FeMn alloys for metallic biodegradable stents: Degradation and cell viability studies. Acta Biomaterialia 2010;6: 1852-1860.
    • (2010) Acta Biomaterialia , vol.6 , pp. 1852-1860
    • Hermawan, H.1    Purnama, A.2    Dube, D.3    Couet, J.4    Mantovani, D.5
  • 21
    • 84855958610 scopus 로고    scopus 로고
    • accessed 2011.06.06
    • Goodfellow Corporation. Iron (Fe)-material information. http://www.goodfellow.com/csp/active/STATICIAlIron.HTM L (accessed 2011.06.06).
    • Iron (Fe)-material Information
  • 23
    • 33747740694 scopus 로고    scopus 로고
    • Are resorbable implants about to become a reality?
    • DOI 10.1017/S1047951106000011, PII S1047951106000011
    • Peuster M, Beerbaum P, Bach FW, Hauser H. Are resorbable implants about to become a reality? Cardiol Young 2006; 16: 107-116. (Pubitemid 44269389)
    • (2006) Cardiology in the Young , vol.16 , Issue.2 , pp. 107-116
    • Peuster, M.1    Beerbaum, P.2    Bach, F.-W.3    Hauser, H.4
  • 24
    • 28844455504 scopus 로고    scopus 로고
    • First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
    • DOI 10.1002/ccd.20520
    • Zartner P, Cesnjevar R, Singer H, Weyand M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheter Cardiovasc Interv 2005; 66: 590-594. (Pubitemid 41779033)
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , Issue.4 , pp. 590-594
    • Zartner, P.1    Cesnjevar, R.2    Singer, H.3    Weyand, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.