메뉴 건너뛰기




Volumn 9, Issue 1, 2012, Pages

Design and evaluation of a low-cost instrumented glove for hand function assessment

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTHROMETRY; ARTICLE; FEMALE; HAND; HAND STRENGTH; HUMAN; INSTRUMENTATION; JOINT CHARACTERISTICS AND FUNCTIONS; MALE; MIDDLE AGED; PHYSIOLOGY; SPINAL CORD INJURY; VALIDATION STUDY;

EID: 84855791971     PISSN: None     EISSN: 17430003     Source Type: Journal    
DOI: 10.1186/1743-0003-9-2     Document Type: Article
Times cited : (94)

References (22)
  • 2
    • 74849083847 scopus 로고    scopus 로고
    • ARMin III - Arm therapy exoskeleton with an ergonomic shoulder actuation
    • 10.1080/11762320902840179
    • ARMin III-arm therapy exoskeleton with an ergonomic shoulder actuation. Nef T, Guidali M, Riener R, Appl Bionic Biomech 2009 6 2 127 142 10.1080/11762320902840179
    • (2009) Appl Bionic Biomech , vol.6 , Issue.2 , pp. 127-142
    • Nef, T.1    Guidali, M.2    Riener, R.3
  • 5
    • 79957666532 scopus 로고    scopus 로고
    • Upper extremity neurorehabilitation
    • Alberta University, Medicine Department
    • Upper extremity neurorehabilitation. Kowalczewski J, PhD thesis Alberta University, Medicine Department 2009
    • (2009) PhD Thesis
    • Kowalczewski, J.1
  • 6
    • 10444243317 scopus 로고    scopus 로고
    • Modular transcutaneous functional electrical stimulation system
    • DOI 10.1016/j.medengphy.2004.08.016, PII S1350453304001511
    • Modular transcutaneous functional electrical stimulation system. Popovic MR, Keller T, Med Eng Phys 2005 27 81 92 10.1016/j.medengphy.2004.08.016 15604009 (Pubitemid 39643168)
    • (2005) Medical Engineering and Physics , vol.27 , Issue.1 , pp. 81-92
    • Popovic, M.R.1    Keller, T.2
  • 7
    • 0034888348 scopus 로고    scopus 로고
    • Functional electrical stimulation for grasping and walking: Indications and limitations
    • DOI 10.1038/sj.sc.3101191
    • Functional electrical stimulation for grasping and walking: indications and limitations. Popovic MR, Curt A, Keller T, Dietz V, Spinal Cord 2001 39 403 412 10.1038/sj.sc.3101191 11512070 (Pubitemid 32769801)
    • (2001) Spinal Cord , vol.39 , Issue.8 , pp. 403-412
    • Popovic, M.R.1    Curt, A.2    Keller, T.3    Dietz, V.4
  • 8
    • 0019854870 scopus 로고
    • A performance test for assessment of upper limb function in physical rehabilitation treatment and research
    • A performance test for assessment of upper limb function in physical rehabilitation treatment and research. Lyle RC, Int J Rehab Research 1981 4 4 483 492 10.1097/00004356-198112000-00001 (Pubitemid 12144660)
    • (1981) International Journal of Rehabilitation Research , vol.4 , Issue.4 , pp. 483-492
    • Lyle, R.C.1
  • 9
    • 0024567030 scopus 로고
    • Forced use of hemiplegic upper extremities to reverse the effect of learned nonuse among chronic stroke and head-injured patients
    • DOI 10.1016/S0014-4886(89)80005-6
    • Forced use of hemiplegic upper extremities to reverse the effect of learned nonuse among chronic stroke and head-injured patients. Wolf SL, Lecraw DE, Barton LA, Jann BB, Exp Neurol 1989 104 125 132 10.1016/S0014-4886(89)80005- 6 2707361 (Pubitemid 19122839)
    • (1989) Experimental Neurology , vol.104 , Issue.2 , pp. 125-132
    • Wolf, S.L.1    Lecraw, E.2    Barton, L.A.3    Jann, B.B.4
  • 10
    • 46849097984 scopus 로고    scopus 로고
    • A survey of glove-based systems and their applications
    • A survey of glove-based systems and their applications. Dipietro L, Sabatini AM, Dario P, IEEE Trans Syst Man Cyber 2008 38 4 461 482
    • (2008) IEEE Trans Syst Man Cyber , vol.38 , Issue.4 , pp. 461-482
    • Dipietro, L.1    Sabatini, A.M.2    Dario, P.3
  • 11
    • 17844399225 scopus 로고    scopus 로고
    • Design considerations for a wearable monitor to measure finger posture
    • 15730560
    • Design considerations for a wearable monitor to measure finger posture. Simone LK, Kamper DG, J Neuroeng Rehabil 2005 2 5 1 10 15730560
    • (2005) J Neuroeng Rehabil , vol.2 , Issue.5 , pp. 1-10
    • Simone, L.K.1    Kamper, D.G.2
  • 12
    • 59249094359 scopus 로고    scopus 로고
    • Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings
    • Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings. Gentner R, Classen J, J Neuroscience Meth 2009 178 2 138 147
    • (2009) J Neuroscience Meth , vol.178 , Issue.2 , pp. 138-147
    • Gentner, R.1    Classen, J.2
  • 13
    • 33846910193 scopus 로고    scopus 로고
    • A low cost instrumented glove for extended monitoring and functional hand assessment
    • DOI 10.1016/j.jneumeth.2006.09.021, PII S0165027006004754
    • A low cost instrumented glove for extended monitoring and functional hand assessment. Simone LK, Sundarrajan N, Luo X, Jia Y, Kamper DG, J Neurosci Meth 2007 160 335 348 10.1016/j.jneumeth.2006.09.021 (Pubitemid 46241472)
    • (2007) Journal of Neuroscience Methods , vol.160 , Issue.2 , pp. 335-348
    • Simone, L.K.1    Sundarrajan, N.2    Luo, X.3    Jia, Y.4    Kamper, D.G.5
  • 19
    • 0029024848 scopus 로고
    • Sollerman hand function test: A standardised method and its use in tetraplegic patients
    • 10.3109/02844319509034334 7569815
    • Sollerman hand function test: a standardised method and its use in tetraplegic patients. Sollerman C, Ejeskär A, Scand J Plast Reconstr Surg Hand Surg 1995 29 167 176 10.3109/02844319509034334 7569815
    • (1995) Scand J Plast Reconstr Surg Hand Surg , vol.29 , pp. 167-176
    • Sollerman, C.1    Ejeskär, A.2
  • 20
    • 58149501620 scopus 로고    scopus 로고
    • Clinimetric properties of instruments to assess activities in patients with hand injury: A systematic review of the literature
    • 10.1016/j.apmr.2008.06.024 19154842
    • Clinimetric properties of instruments to assess activities in patients with hand injury: a systematic review of the literature. van de Ven-Stevens LA, Munneke M, Terwee CB, Spauwen PH, van der Linde H, Arch Phys Med Rehabil 2009 90 151 169 10.1016/j.apmr.2008.06.024 19154842
    • (2009) Arch Phys Med Rehabil , vol.90 , pp. 151-169
    • Van De Ven-Stevens, L.A.1    Munneke, M.2    Terwee, C.B.3    Spauwen, P.H.4    Van Der Linde, H.5
  • 21
    • 0038077369 scopus 로고    scopus 로고
    • Evaluation of an instrumented glove for hand-movement acquisition
    • 15077642
    • Evaluation of an instrumented glove for hand-movement acquisition. Dipietro L, Sabatini AM, Dario P, J Rehabil Res Dev 2003 40 2 179 190 15077642
    • (2003) J Rehabil Res Dev , vol.40 , Issue.2 , pp. 179-190
    • Dipietro, L.1    Sabatini, A.M.2    Dario, P.3
  • 22
    • 0025479959 scopus 로고
    • Evaluation of a fiber optic glove for semi-automated goniometric measurements
    • 10.1682/JRRD.1990.10.0411 2089151
    • Evaluation of a fiber optic glove for semi-automated goniometric measurements. Wise S, Gardner W, Sabelman E, Valainis E, Wong Y, Glass K, Drace J, Rosen JM, J Rehabil Res Dev 1990 27 4 411 424 10.1682/JRRD.1990.10.0411 2089151
    • (1990) J Rehabil Res Dev , vol.27 , Issue.4 , pp. 411-424
    • Wise, S.1    Gardner, W.2    Sabelman, E.3    Valainis, E.4    Wong, Y.5    Glass, K.6    Drace, J.7    Rosen, J.M.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.