메뉴 건너뛰기




Volumn 39, Issue 1, 2012, Pages 237-245

Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy

Author keywords

biological based optimization; liver; lung; prostate; SBRT; VMAT

Indexed keywords

BIOLOGICAL ORGANS; LIVER; QUALITY ASSURANCE; RADIOTHERAPY; TUMORS; UROLOGY;

EID: 84855464808     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3668059     Document Type: Article
Times cited : (26)

References (22)
  • 1
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • 10.1118/1.2818738
    • K. Otto, Volumetric modulated arc therapy: IMRT in a single gantry arc., Med. Phys. 35, 310-317 (2008). 10.1118/1.2818738
    • (2008) Med. Phys. , vol.35 , pp. 310-317
    • Otto, K.1
  • 2
    • 51849157038 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy for delivery of prostate radiotherapy: Comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy
    • 10.1016/j.ijrob2008.02.047
    • D. Palma, E. Vollans, K. James, S. Nakano, V. Moiseenko, R. Shaffer, M. McKenzie, J. Morris, and K. Otto, Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy., Int. J. Radiat. Oncol. Biol. Phys. 72, 996-1001 (2008). 10.1016/j.ijrobp.2008.02.047
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.72 , pp. 996-1001
    • Palma, D.1    Vollans, E.2    James, K.3    Nakano, S.4    Moiseenko, V.5    Shaffer, R.6    McKenzie, M.7    Morris, J.8    Otto, K.9
  • 3
    • 70350499496 scopus 로고    scopus 로고
    • Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?
    • 10.1016/j.radonc.2009.08.015
    • M. Guckenberger, A. Richter, T. Krieger, J. Wilbert, K. Baier, and M. Flentje, Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?, Radiother. Oncol. 93, 259-265 (2009). 10.1016/j.radonc.2009.08.015
    • (2009) Radiother. Oncol. , vol.93 , pp. 259-265
    • Guckenberger, M.1    Richter, A.2    Krieger, T.3    Wilbert, J.4    Baier, K.5    Flentje, M.6
  • 4
    • 77951862144 scopus 로고    scopus 로고
    • Clinical applications of volumetric modulated arc therapy
    • 10.1016/j.ijrob2009.08.032
    • M. M. Matuszak, D. Yan, I. Grills, and A. Martinez, Clinical applications of volumetric modulated arc therapy., Int. J. Radiat. Oncol. Biol. Phys. 77, 608-616 (2010). 10.1016/j.ijrobp.2009.08.032
    • (2010) Int. J. Radiat. Oncol. Biol. Phys. , vol.77 , pp. 608-616
    • Matuszak, M.M.1    Yan, D.2    Grills, I.3    Martinez, A.4
  • 5
    • 60549115290 scopus 로고    scopus 로고
    • RapidArc volumetric modulated therapy planning for prostate cancer patients
    • r-Kristoffersen, L. Ohlhues, J. Medin, and S. Korreman, , 10.1080/02841860802266748
    • F. Kj r-Kristoffersen, L. Ohlhues, J. Medin, and S. Korreman, RapidArc volumetric modulated therapy planning for prostate cancer patients., Acta Oncol. 48, 227-232 (2009). 10.1080/02841860802266748
    • (2009) Acta Oncol. , vol.48 , pp. 227-232
    • Kj, F.1
  • 6
    • 58149345036 scopus 로고    scopus 로고
    • Commissioning of volumetric modulated arc therapy (VMAT)
    • 10.1016/j.ijrob2008.08.055
    • J. L. Bedford and A. P. Warrington, Commissioning of volumetric modulated arc therapy (VMAT)., Int. J. Radiat. Oncol. Biol. Phys. 73, 537-545 (2009). 10.1016/j.ijrobp.2008.08.055
    • (2009) Int. J. Radiat. Oncol. Biol. Phys. , vol.73 , pp. 537-545
    • Bedford, J.L.1    Warrington, A.P.2
  • 7
    • 77954168345 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis
    • 10.1016/j.radonc.2009.12.039
    • S. D. McGrath, M. M. Matuszak, D. Yan, L. L. Kestin, A. A. Martinez, and I. S. Grills, Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis., Radiother. Oncol. 95, 153-157 (2010). 10.1016/j.radonc.2009.12.039
    • (2010) Radiother. Oncol. , vol.95 , pp. 153-157
    • McGrath, S.D.1    Matuszak, M.M.2    Yan, D.3    Kestin, L.L.4    Martinez, A.A.5    Grills, I.S.6
  • 8
    • 11144350193 scopus 로고    scopus 로고
    • Impact of tumor repopulation on radiotherapy planning
    • 10.1016/j.ijrob2004.09.043
    • J. Z. Wang and X. A. Li, Impact of tumor repopulation on radiotherapy planning., Int. J. Radiat. Oncol. Biol. Phys. 61, 220-227 (2005). 10.1016/j.ijrobp.2004.09.043
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.61 , pp. 220-227
    • Wang, J.Z.1    Li, X.A.2
  • 9
    • 56749175428 scopus 로고    scopus 로고
    • Evaluation of a commercial biologically based IMRT treatment planning system
    • 10.1118/1.3013556
    • V. A. Semenenko, B. Reitz, E. Day, X. S. Qi, M. Miften, and X. A. Li, Evaluation of a commercial biologically based IMRT treatment planning system., Med. Phys. 35, 5851-5860 (2008). 10.1118/1.3013556
    • (2008) Med. Phys. , vol.35 , pp. 5851-5860
    • Semenenko, V.A.1    Reitz, B.2    Day, E.3    Qi, X.S.4    Miften, M.5    Li, X.A.6
  • 10
    • 85027239359 scopus 로고    scopus 로고
    • Monaco 2.04 Training, (private communication)
    • Elekta, Monaco 2.04 Training, (private communication).
    • Elekta1
  • 11
    • 0141631886 scopus 로고    scopus 로고
    • From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning
    • 10.1118/1.1598852
    • C. Thieke, T. Bortfeld, A. Niemierko, and S. Nill, From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning., Med. Phys. 30, 2332-2339 (2003). 10.1118/1.1598852
    • (2003) Med. Phys. , vol.30 , pp. 2332-2339
    • Thieke, C.1    Bortfeld, T.2    Niemierko, A.3    Nill, S.4
  • 12
    • 0039728357 scopus 로고    scopus 로고
    • An objective function for radiation treatment optimization based on local biological measures
    • 10.1088/0031-9155/44/2/014
    • M. Alber and F. Nusslin, An objective function for radiation treatment optimization based on local biological measures., Phys. Med. Biol. 44, 479-493 (1999). 10.1088/0031-9155/44/2/014
    • (1999) Phys. Med. Biol. , vol.44 , pp. 479-493
    • Alber, M.1    Nusslin, F.2
  • 13
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • 10.1118/1.598063
    • A. Niemierko, Reporting and analyzing dose distributions: A concept of equivalent uniform dose., Med. Phys. 24, 103-110 (1997). 10.1118/1.598063
    • (1997) Med. Phys. , vol.24 , pp. 103-110
    • Niemierko, A.1
  • 14
    • 0001328719 scopus 로고    scopus 로고
    • A generalized concept of equivalent uniform dose (EUD)
    • A. Niemierko, A generalized concept of equivalent uniform dose (EUD)., Med. Phys. 26, 1101 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1101
    • Niemierko, A.1
  • 15
    • 0027316070 scopus 로고
    • Commissioning and quality assurance of treatment planning computers
    • 10.1016/0360-3016(93)90206-B
    • J. van Dyk, R. B. Barnett, J. E. Cygler, and P. C. Shragge, Commissioning and quality assurance of treatment planning computers., Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993). 10.1016/0360-3016(93)90206-B
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.26 , pp. 261-273
    • Van Dyk, J.1    Barnett, R.B.2    Cygler, J.E.3    Shragge, P.C.4
  • 17
    • 0342617576 scopus 로고    scopus 로고
    • A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
    • 10.1016/S0360-3016(96)00601-3
    • A. van't Riet, A. C. A. Mak, M. A. Moerland, L. H. Elders, and W. van der Zee, A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate., Int. J. Radiat. Oncol. Biol. Phys. 37, 731-736 (1997). 10.1016/S0360-3016(96)00601-3
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.37 , pp. 731-736
    • Van'T Riet, A.1    Mak, A.C.A.2    Moerland, M.A.3    Elders, L.H.4    Van Der Zee, W.5
  • 19
    • 70349337606 scopus 로고    scopus 로고
    • Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs
    • 10.1016/j.radonc.2009.05.020
    • W. Verbakel, S. Senan, J. P. Cuijpers, B. J. Slotman, and F. J. Lagerwaard, Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs., Radiother. Oncol. 93, 122-124 (2009). 10.1016/j.radonc.2009.05.020
    • (2009) Radiother. Oncol. , vol.93 , pp. 122-124
    • Verbakel, W.1    Senan, S.2    Cuijpers, J.P.3    Slotman, B.J.4    Lagerwaard, F.J.5
  • 20
    • 36749095639 scopus 로고    scopus 로고
    • A new dose-volume-based plan quality index for IMRT plan comparison
    • 10.1016/j.radonc.2007.10.018
    • L. H. T. Leung, M. W. K. Kan, A. C. K. Cheng, W. K. H. Wong, and C. C. Yau, A new dose-volume-based plan quality index for IMRT plan comparison., Radiother. Oncol. 85, 407-417 (2007). 10.1016/j.radonc.2007.10.018
    • (2007) Radiother. Oncol. , vol.85 , pp. 407-417
    • Leung, L.H.T.1    Kan, M.W.K.2    Cheng, A.C.K.3    Wong, W.K.H.4    Yau, C.C.5
  • 21
    • 11144340904 scopus 로고    scopus 로고
    • Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets
    • 10.1016/j.ijrob2004.03.028
    • U. Haedinger, T. Krieger, M. Flentje, and J. Wulf, Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets., Int. J. Radiat. Oncol. Biol. Phys. 61, 239-249 (2005). 10.1016/j.ijrobp.2004.03.028
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.61 , pp. 239-249
    • Haedinger, U.1    Krieger, T.2    Flentje, M.3    Wulf, J.4
  • 22
    • 0032841354 scopus 로고    scopus 로고
    • Determining the optimal block margin on the planning target volume for extracranial stereotactic radiotherapy
    • 10.1016/S0360-3016(99)00203-5
    • R. M. Cardinale, Q. W. Wu, S. H. Benedict, B. D. Kavanagh, E. Bunp, and R. Mohan, Determining the optimal block margin on the planning target volume for extracranial stereotactic radiotherapy., Int. J. Radiat. Oncol. Biol. Phys. 45, 515-520 (1999). 10.1016/S0360-3016(99)00203-5
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.45 , pp. 515-520
    • Cardinale, R.M.1    Wu, Q.W.2    Benedict, S.H.3    Kavanagh, B.D.4    Bunp, E.5    Mohan, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.