메뉴 건너뛰기




Volumn 35, Issue 12, 2008, Pages 5851-5860

Evaluation of a commercial biologically based IMRT treatment planning system

Author keywords

Biological optimization; Dose volume based optimization; Dosimetric plan comparisons; IMRT treatment planning

Indexed keywords

BIOMEDICAL ENGINEERING; DOSIMETRY; FUNCTION EVALUATION; QUALITY CONTROL; RADIOTHERAPY;

EID: 56749175428     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3013556     Document Type: Article
Times cited : (90)

References (42)
  • 1
    • 0026582679 scopus 로고
    • An algorithm for maximizing the probability of complication-free tumour control in radiation therapy
    • P. Källman, B. K. Lind, and A. Brahme, " An algorithm for maximizing the probability of complication-free tumour control in radiation therapy.," Phys. Med. Biol. 37, 871-890 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 871-890
    • Källman, P.1    Lind, B.K.2    Brahme, A.3
  • 3
    • 0026741169 scopus 로고
    • Optimization of 3D radiation therapy with both physical and biological end points and constraints
    • A. Niemierko, M. Urie, and M. Goitein, " Optimization of 3D radiation therapy with both physical and biological end points and constraints.," Int. J. Radiat. Oncol., Biol., Phys. 23, 99-108 (1992).
    • (1992) Int. J. Radiat. Oncol., Biol., Phys. , vol.23 , pp. 99-108
    • Niemierko, A.1    Urie, M.2    Goitein, M.3
  • 4
    • 0028840558 scopus 로고
    • Optimization of intensity-modulated 3D conformal treatment plans based on biological indices
    • X. H. Wang, R. Mohan, A. Jackson, S. A. Leibel, Z. Fuks, and C. C. Ling, " Optimization of intensity-modulated 3D conformal treatment plans based on biological indices.," Radiother. Oncol. 37, 140-152 (1995).
    • (1995) Radiother. Oncol. , vol.37 , pp. 140-152
    • Wang, X.H.1    Mohan, R.2    Jackson, A.3    Leibel, S.A.4    Fuks, Z.5    Ling, C.C.6
  • 5
    • 0343962993 scopus 로고    scopus 로고
    • Optimization of beam weights in conformal radiotherapy planning of stage III non-small cell lung cancer: Effects on therapeutic ratio
    • W. R. De Gersem, S. Derycke, C. De Wagter, and W. C. De Neve, " Optimization of beam weights in conformal radiotherapy planning of stage III non-small cell lung cancer: Effects on therapeutic ratio.," Int. J. Radiat. Oncol., Biol., Phys. 47, 255-260 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.47 , pp. 255-260
    • De Gersem, W.R.1    Derycke, S.2    De Wagter, C.3    De Neve, W.C.4
  • 7
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • A. Niemierko, " Reporting and analyzing dose distributions: A concept of equivalent uniform dose.," Med. Phys. 24, 103-110 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 103-110
    • Niemierko, A.1
  • 8
    • 0001328719 scopus 로고    scopus 로고
    • A generalized concept of equivalent uniform dose (EUD)
    • A. Niemierko, " A generalized concept of equivalent uniform dose (EUD).," Med. Phys. 26, 1101 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1101
    • Niemierko, A.1
  • 9
    • 0037152468 scopus 로고    scopus 로고
    • The generalized equivalent uniform dose function as a basis for intensity-modulated treatment planning
    • B. Choi and J. O. Deasy, " The generalized equivalent uniform dose function as a basis for intensity-modulated treatment planning.," Phys. Med. Biol. 47, 3579-3589 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 3579-3589
    • Choi, B.1    Deasy, J.O.2
  • 10
    • 0036138763 scopus 로고    scopus 로고
    • Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose
    • Q. Wu, R. Mohan, A. Niemierko, and R. Schmidt-Ullrich, " Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose.," Int. J. Radiat. Oncol., Biol., Phys. 52, 224-235 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.52 , pp. 224-235
    • Wu, Q.1    Mohan, R.2    Niemierko, A.3    Schmidt-Ullrich, R.4
  • 11
    • 0141631886 scopus 로고    scopus 로고
    • From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning
    • C. Thieke, T. Bortfeld, A. Niemierko, and S. Nill, " From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning.," Med. Phys. 30, 2332-2339 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2332-2339
    • Thieke, C.1    Bortfeld, T.2    Niemierko, A.3    Nill, S.4
  • 12
    • 0344393791 scopus 로고    scopus 로고
    • Inverse treatment planning by physically constrained minimization of a biological objective function
    • P. Stavrev, D. Hristov, B. Warkentin, E. Sham, N. Stavreva, and B. G. Fallone, " Inverse treatment planning by physically constrained minimization of a biological objective function.," Med. Phys. 30, 2948-2958 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2948-2958
    • Stavrev, P.1    Hristov, D.2    Warkentin, B.3    Sham, E.4    Stavreva, N.5    Fallone, B.G.6
  • 13
    • 9744275912 scopus 로고    scopus 로고
    • Clinical knowledge-based inverse treatment planning
    • Y. Yang and L. Xing, " Clinical knowledge-based inverse treatment planning.," Phys. Med. Biol. 49, 5101-5117 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5101-5117
    • Yang, Y.1    Xing, L.2
  • 14
    • 18944407561 scopus 로고    scopus 로고
    • Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors
    • E. Thomas, O. Chapet, M. L. Kessler, T. S. Lawrence, and R. K. Ten Haken, " Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors.," Int. J. Radiat. Oncol., Biol., Phys. 62, 571-578 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , pp. 571-578
    • Thomas, E.1    Chapet, O.2    Kessler, M.L.3    Lawrence, T.S.4    Ten Haken, R.K.5
  • 15
    • 0039728357 scopus 로고    scopus 로고
    • An objective function for radiation treatment optimization based on local biological measures
    • M. Alber and F. Nüsslin, " An objective function for radiation treatment optimization based on local biological measures.," Phys. Med. Biol. 44, 479-493 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 479-493
    • Alber, M.1    Nüsslin, F.2
  • 16
    • 0006015843 scopus 로고    scopus 로고
    • Ph.D. dissertation, University of Tübingen, Tübingen, Germany, available at.
    • M. Alber, " A concept for the optimization of radiotherapy.," Ph.D. dissertation, University of Tübingen, Tübingen, Germany, 2000, available at tobias-lib.ub.uni-tuebingen.de/volltexte/2001/221/.
    • (2000) A Concept for the Optimization of Radiotherapy
    • Alber, M.1
  • 17
    • 22844434023 scopus 로고    scopus 로고
    • A finite size pencil beam for IMRT dose optimization
    • U. Jeleń, M. Söhn and M. Alber, " A finite size pencil beam for IMRT dose optimization.," Phys. Med. Biol. 50, 1747-1766 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1747-1766
    • Jeleń, U.1    Söhn, M.2    Alber, M.3
  • 18
    • 34047264289 scopus 로고    scopus 로고
    • A finite size pencil beam algorithm for IMRT dose optimization: Density corrections
    • U. Jeleń and M. Alber, " A finite size pencil beam algorithm for IMRT dose optimization: Density corrections.," Phys. Med. Biol. 52, 617-633 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 617-633
    • Jeleń, U.1    Alber, M.2
  • 19
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • M. Fippel, " Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm.," Med. Phys. 26, 1466-1475 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1466-1475
    • Fippel, M.1
  • 20
    • 0037340926 scopus 로고    scopus 로고
    • A virtual photon energy fluence model for Monte Carlo dose calculation
    • M. Fippel, F. Haryanto, O. Dohm, F. Nüsslin, and S. Kriesen, " A virtual photon energy fluence model for Monte Carlo dose calculation.," Med. Phys. 30, 301-311 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 301-311
    • Fippel, M.1    Haryanto, F.2    Dohm, O.3    Nüsslin, F.4    Kriesen, S.5
  • 21
    • 0034129338 scopus 로고    scopus 로고
    • Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
    • M. Miften, M. Wiesmeyer, S. Monthofer, and K. Krippner, " Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system.," Phys. Med. Biol. 45, 817-833 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 817-833
    • Miften, M.1    Wiesmeyer, M.2    Monthofer, S.3    Krippner, K.4
  • 22
    • 85024951939 scopus 로고    scopus 로고
    • Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system
    • M. Miften, M. Wiesmeyer, A. Kapur, and C. M. Ma, " Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system.," J. Appl. Clin. Med. Phys. 2, 21-31 (2001).
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , pp. 21-31
    • Miften, M.1    Wiesmeyer, M.2    Kapur, A.3    Ma, C.M.4
  • 23
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • D. W. Rogers, B. A. Faddegon, G. X. Ding, C. M. Ma, J. We, and T. R. Mackie, " BEAM: A Monte Carlo code to simulate radiotherapy treatment units.," Med. Phys. 22, 503-524 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 503-524
    • Rogers, D.W.1    Faddegon, B.A.2    Ding, G.X.3    Ma, C.M.4    We, J.5    MacKie, T.R.6
  • 24
    • 0037037757 scopus 로고    scopus 로고
    • Tools for the analysis of dose optimization. II. Sensitivity analysis
    • M. Alber, M. Birkner, and F. Nüsslin, " Tools for the analysis of dose optimization. II. Sensitivity analysis.," Phys. Med. Biol. 47, N265-N270 (2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Alber, M.1    Birkner, M.2    Nüsslin, F.3
  • 25
    • 0022323855 scopus 로고
    • Complication probability as assessed from dose-volume histograms
    • J. T. Lyman, " Complication probability as assessed from dose-volume histograms.," Radiat. Res. Suppl. 8, S13-S19 (1985).
    • (1985) Radiat. Res. Suppl. , vol.8
    • Lyman, J.T.1
  • 26
    • 0024317128 scopus 로고
    • Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method
    • G. J. Kutcher and C. Burman, " Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method.," Int. J. Radiat. Oncol., Biol., Phys. 16, 1623-1630 (1989).
    • (1989) Int. J. Radiat. Oncol., Biol., Phys. , vol.16 , pp. 1623-1630
    • Kutcher, G.J.1    Burman, C.2
  • 27
    • 36649024104 scopus 로고    scopus 로고
    • Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer
    • Y. Kim, D. S. Parda, M. G. Trombetta, A. Colonias, E. D. Werts, L. Miller, and M. Miften, " Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer.," Med. Phys. 34, 4640-4648 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 4640-4648
    • Kim, Y.1    Parda, D.S.2    Trombetta, M.G.3    Colonias, A.4    Werts, E.D.5    Miller, L.6    Miften, M.7
  • 30
    • 24944584090 scopus 로고    scopus 로고
    • Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma
    • X. Wang, X. Zhang, L. Dong, H. Liu, M. Gillin, A. Ahamad, K. Ang, and R. Mohan, " Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma.," Int. J. Radiat. Oncol., Biol., Phys. 63, 594-601 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.63 , pp. 594-601
    • Wang, X.1    Zhang, X.2    Dong, L.3    Liu, H.4    Gillin, M.5    Ahamad, A.6    Ang, K.7    Mohan, R.8
  • 31
    • 41849099985 scopus 로고    scopus 로고
    • Comparison of IMRT planning with two-step and one-step optimization: A way to simplify IMRT
    • E. Ludlum and P. Xia, " Comparison of IMRT planning with two-step and one-step optimization: A way to simplify IMRT.," Phys. Med. Biol. 53, 807-821 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 807-821
    • Ludlum, E.1    Xia, P.2
  • 32
    • 0342699601 scopus 로고    scopus 로고
    • Intensity modulated photon beams subject to a minimal surface smoothing constraint
    • M. Alber and F. Nüsslin, " Intensity modulated photon beams subject to a minimal surface smoothing constraint.," Phys. Med. Biol. 45, N49-N52 (2000).
    • (2000) Phys. Med. Biol. , vol.45
    • Alber, M.1    Nüsslin, F.2
  • 33
    • 0035739248 scopus 로고    scopus 로고
    • Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery
    • M. Alber and F. Nüsslin, " Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery.," Phys. Med. Biol. 46, 3229-3239 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3229-3239
    • Alber, M.1    Nüsslin, F.2
  • 34
    • 0034919105 scopus 로고    scopus 로고
    • A variable fluence step clustering and segmentation algorithm for step and shoot IMRT
    • W. Bär, M. Alber, and F. Nüsslin, " A variable fluence step clustering and segmentation algorithm for step and shoot IMRT.," Phys. Med. Biol. 46, 1997-2007 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1997-2007
    • Bär, W.1    Alber, M.2    Nüsslin, F.3
  • 35
    • 0032848977 scopus 로고    scopus 로고
    • Optimization of the dose level for a given treatment plan to maximize the complication-free tumor cure
    • B. K. Lind, P. Mavroidis, S. Hyödynmaa, and C. Kappas, " Optimization of the dose level for a given treatment plan to maximize the complication-free tumor cure.," Acta Oncol. 38, 787-798 (1999).
    • (1999) Acta Oncol. , vol.38 , pp. 787-798
    • Lind, B.K.1    Mavroidis, P.2    Hyödynmaa, S.3    Kappas, C.4
  • 38
    • 34748922860 scopus 로고    scopus 로고
    • BGRT: Biologically guided radiation therapy-The future is fast approaching!
    • R. D. Stewart and X. A. Li, " BGRT: Biologically guided radiation therapy-The future is fast approaching!," Med. Phys. 34, 3739-3751 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 3739-3751
    • Stewart, R.D.1    Li, X.A.2
  • 40
    • 3042634478 scopus 로고    scopus 로고
    • Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions
    • S. Das, M. Miften, S. Zhou, M. Bell, M. Munley, C. Whiddon, O. Craciunescu, A. Baydush, T. Wong, J. Rosenman, M. Dewhirst, and L. Marks, " Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions.," Med. Phys. 31, 1398-1408 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1398-1408
    • Das, S.1    Miften, M.2    Zhou, S.3    Bell, M.4    Munley, M.5    Whiddon, C.6    Craciunescu, O.7    Baydush, A.8    Wong, T.9    Rosenman, J.10    Dewhirst, M.11    Marks, L.12
  • 41
    • 13344277921 scopus 로고    scopus 로고
    • Theragnostic imaging for radiation oncology: Dose-painting by numbers
    • S. M. Bentzen, " Theragnostic imaging for radiation oncology: Dose-painting by numbers.," Lancet Oncol. 6, 112-117 (2005).
    • (2005) Lancet Oncol. , vol.6 , pp. 112-117
    • Bentzen, S.M.1
  • 42
    • 34147140787 scopus 로고    scopus 로고
    • Development of an inverse optimization package to plan nonuniform dose distributions based on spatially inhomogeneous radiosensitivity extracted from biological images
    • G. P. Chen, E. Ahunbay, C. Schultz, and X. A. Li, " Development of an inverse optimization package to plan nonuniform dose distributions based on spatially inhomogeneous radiosensitivity extracted from biological images.," Med. Phys. 34, 1198-1205 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 1198-1205
    • Chen, G.P.1    Ahunbay, E.2    Schultz, C.3    Li, X.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.