메뉴 건너뛰기




Volumn 59, Issue 3, 2012, Pages 2167-2174

Reducing image artefacts in concurrent TMS/fMRI by passive shimming

Author keywords

Artefacts; Echo planar imaging; Field maps; Functional magnetic resonance imaging; Passive shimming; Transcranial magnetic stimulation

Indexed keywords

STAINLESS STEEL;

EID: 84855436025     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2011.10.013     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 0033995431 scopus 로고    scopus 로고
    • Artifacts caused by transcranial magnetic stimulation coils and EEG electrodes in T(2)*-weighted echo-planar imaging
    • Baudewig J., Paulus W., Frahm J. Artifacts caused by transcranial magnetic stimulation coils and EEG electrodes in T(2)*-weighted echo-planar imaging. Magn. Reson. Imaging 2000, 18:479-484.
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 479-484
    • Baudewig, J.1    Paulus, W.2    Frahm, J.3
  • 2
    • 0035900331 scopus 로고    scopus 로고
    • Functional MRI of cortical activations induced by transcranial magnetic stimulation (TMS)
    • Baudewig J., Siebner H.R., Bestmann S., Tergau F., Tings T., Paulus W., Frahm J. Functional MRI of cortical activations induced by transcranial magnetic stimulation (TMS). Neuroreport 2001, 12:3543-3548.
    • (2001) Neuroreport , vol.12 , pp. 3543-3548
    • Baudewig, J.1    Siebner, H.R.2    Bestmann, S.3    Tergau, F.4    Tings, T.5    Paulus, W.6    Frahm, J.7
  • 5
    • 0142121823 scopus 로고    scopus 로고
    • A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI
    • Bohning D.E., Denslow S., Bohning P.A., Walker J.A., George M.S. A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI. Clin. Neurophysiol. 2003, 114:2210-2219.
    • (2003) Clin. Neurophysiol. , vol.114 , pp. 2210-2219
    • Bohning, D.E.1    Denslow, S.2    Bohning, P.A.3    Walker, J.A.4    George, M.S.5
  • 8
    • 0021786367 scopus 로고
    • Shimming a superconducting nuclear-magnetic-resonance imaging magnet with steel
    • Hoult D.I., Lee D. Shimming a superconducting nuclear-magnetic-resonance imaging magnet with steel. Rev. Sci. Instrum. 1985, 56:131-136.
    • (1985) Rev. Sci. Instrum. , vol.56 , pp. 131-136
    • Hoult, D.I.1    Lee, D.2
  • 9
    • 0037225733 scopus 로고    scopus 로고
    • Fast, automated, N-dimensional phase-unwrapping algorithm
    • Jenkinson M. Fast, automated, N-dimensional phase-unwrapping algorithm. Magn. Reson. Med. 2003, 49:193-197.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 193-197
    • Jenkinson, M.1
  • 10
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimisation for the robust and accurate linear registration and motion correction of brain images
    • Jenkinson M., Bannister P.R., Brady J.M., Smith S.M. Improved optimisation for the robust and accurate linear registration and motion correction of brain images. Neuroimage 2002, 17:825-841.
    • (2002) Neuroimage , vol.17 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.R.2    Brady, J.M.3    Smith, S.M.4
  • 11
    • 60349107122 scopus 로고    scopus 로고
    • New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex study
    • Moisa M., Pohmann R., Ewald L., Thielscher A. New coil positioning method for interleaved transcranial magnetic stimulation (TMS)/functional MRI (fMRI) and its validation in a motor cortex study. J. Magn. Reson. Imaging 2009, 29:189-197.
    • (2009) J. Magn. Reson. Imaging , vol.29 , pp. 189-197
    • Moisa, M.1    Pohmann, R.2    Ewald, L.3    Thielscher, A.4
  • 12
    • 70350004688 scopus 로고    scopus 로고
    • Interleaved TMS/CASL: comparison of different rTMS protocols
    • Moisa M., Pohmann R., Uludag K., Thielscher A. Interleaved TMS/CASL: comparison of different rTMS protocols. Neuroimage 2010, 49:612-620.
    • (2010) Neuroimage , vol.49 , pp. 612-620
    • Moisa, M.1    Pohmann, R.2    Uludag, K.3    Thielscher, A.4
  • 13
    • 0021749809 scopus 로고
    • Magnet field profiling: analysis and correcting coil design
    • Romeo F., Hoult D.I. Magnet field profiling: analysis and correcting coil design. Magn. Reson. Med. 1984, 1:44-65.
    • (1984) Magn. Reson. Med. , vol.1 , pp. 44-65
    • Romeo, F.1    Hoult, D.I.2
  • 14
    • 34447277271 scopus 로고    scopus 로고
    • Imaging the brain activity changes underlying impaired visuospatial judgments: simultaneous FMRI, TMS, and behavioral studies
    • Sack A.T., Kohler A., Bestmann S., Linden D.E., Dechent P., Goebel R., Baudewig J. Imaging the brain activity changes underlying impaired visuospatial judgments: simultaneous FMRI, TMS, and behavioral studies. Cereb. Cortex 2007, 17:2841-2852.
    • (2007) Cereb. Cortex , vol.17 , pp. 2841-2852
    • Sack, A.T.1    Kohler, A.2    Bestmann, S.3    Linden, D.E.4    Dechent, P.5    Goebel, R.6    Baudewig, J.7
  • 15
    • 13544259378 scopus 로고    scopus 로고
    • Saturation in "nonmagnetic" stainless steel
    • Weber C., Fajans J. Saturation in "nonmagnetic" stainless steel. Rev. Sci. Instrum. 1998, 69:3695-3696.
    • (1998) Rev. Sci. Instrum. , vol.69 , pp. 3695-3696
    • Weber, C.1    Fajans, J.2
  • 17
    • 0036846413 scopus 로고    scopus 로고
    • Optimization of static field homogeneity in human brain using diamagnetic passive shims
    • Wilson J.L., Jenkinson M., Jezzard P. Optimization of static field homogeneity in human brain using diamagnetic passive shims. Magn. Reson. Med. 2002, 48:906-914.
    • (2002) Magn. Reson. Med. , vol.48 , pp. 906-914
    • Wilson, J.L.1    Jenkinson, M.2    Jezzard, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.