메뉴 건너뛰기




Volumn 112, Issue 1, 2012, Pages 159-166

Optimized murine lung preparation for detailed structural evaluation via micro-computed tomography

Author keywords

High resolution imaging; Lung morphometry; Perfusion based lung fixation; Quantitative computed tomography

Indexed keywords

ANIMAL; ARTICLE; C57BL MOUSE; COMPUTER ASSISTED TOMOGRAPHY; INSTRUMENTATION; LUNG; MALE; METHODOLOGY; MOUSE; PERFUSION; PHYSIOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 84855394748     PISSN: 87507587     EISSN: 15221601     Source Type: Journal    
DOI: 10.1152/japplphysiol.00550.2011     Document Type: Article
Times cited : (43)

References (34)
  • 1
    • 33749450253 scopus 로고    scopus 로고
    • Anonymous International Committee on Veterinary Gross Anatomical Nomenclature (Online). Hannover, Columbia, Gent, Sapporo. Distributed by Dept. of Veterinary Anatomy, Cornell University through
    • Anonymous. Nomina Anatomica Veterinaria, International Committee on Veterinary Gross Anatomical Nomenclature (Online). Hannover, Columbia, Gent, Sapporo. Distributed by Dept. of Veterinary Anatomy, Cornell University through http://www.wava-Amav.org/2005 [2005].
    • (2005) Nomina Anatomica Veterinaria
  • 5
    • 0034524016 scopus 로고    scopus 로고
    • Animal models of emphysema: The next generations
    • Campbell EJ. Animal models of emphysema: The next generations. J Clin Invest 106: 1445-1446, 2000. (Pubitemid 32038582)
    • (2000) Journal of Clinical Investigation , vol.106 , Issue.12 , pp. 1445-1446
    • Campbell, E.J.1
  • 6
    • 32144443860 scopus 로고    scopus 로고
    • Longitudinal evaluation of tumor metastasis by an FDGmicroPET/ microCT dual-imaging modality in a lung carcinoma-bearing mouse model
    • Chang CH, Jan ML, Fan KH, Wang HE, Tsai TH, Chen CF, Fu YK, Lee TW. Longitudinal evaluation of tumor metastasis by an FDGmicroPET/ microCT dual-imaging modality in a lung carcinoma-bearing mouse model. Anticancer Res 26: 159-166, 2006.
    • (2006) Anticancer Res , vol.26 , pp. 159-166
    • Chang, C.H.1    Jan, M.L.2    Fan, K.H.3    Wang, H.E.4    Tsai, T.H.5    Chen, C.F.6    Fu, Y.K.7    Lee, T.W.8
  • 9
    • 34447120203 scopus 로고    scopus 로고
    • Animal models of pulmonary emphysema: A stereologist's perspective
    • DOI 10.1183/09059180.00010104
    • Fehrenbach H. Animal models of pulmonary emphysema: A stereologist's perspective. Eur Respir Rev 15: 136-147, 2006. (Pubitemid 47035699)
    • (2006) European Respiratory Review , vol.15 , Issue.101 , pp. 136-147
    • Fehrenbach, H.1
  • 14
    • 76149084817 scopus 로고    scopus 로고
    • An official research policy statement of the American Thoracic Society/European Respiratory Society: Standards for quantitative assessment of lung structure
    • Hsia CC, Hyde DM, Ochs M, Weibel ER. An official research policy statement of the American Thoracic Society/European Respiratory Society: Standards for quantitative assessment of lung structure. Am J Respir Crit Care Med 181: 394-418, 2010.
    • (2010) Am J Respir Crit Care Med , vol.181 , pp. 394-418
    • Hsia, C.C.1    Hyde, D.M.2    Ochs, M.3    Weibel, E.R.4
  • 15
    • 0035354205 scopus 로고    scopus 로고
    • Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
    • DOI 10.1109/42.929615, PII S0278006201046882
    • Hu S, Hoffman EA, Reinhardt JM. Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images. IEEE Trans Med Imaging 20: 490-498, 2001. (Pubitemid 32657853)
    • (2001) IEEE Transactions on Medical Imaging , vol.20 , Issue.6 , pp. 490-498
    • Hu, S.1    Hoffman, E.A.2    Reinhardt, J.M.3
  • 17
    • 0022407649 scopus 로고
    • Effects of 10% formalin fixation on fixed lung volume and lung tissue shrinkage . A comparison of eleven laboratory species
    • Lum H, Mitzner W. Effects of 10% formalin fixation on fixed lung volume and lung tissue shrinkage. A comparison of eleven laboratory species. Am Rev Respir Dis 132: 1078-1083, 1985. (Pubitemid 16221400)
    • (1985) American Review of Respiratory Disease , vol.132 , Issue.5 , pp. 1078-1083
    • Lum, H.1    Mitzner, W.2
  • 18
    • 68749106020 scopus 로고    scopus 로고
    • MicroCT for comparative morphology: Simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues
    • Metscher BD. MicroCT for comparative morphology: Simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues. BMC Physiol 9: 11, 2009.
    • (2009) BMC Physiol , vol.9 , pp. 11
    • Metscher, B.D.1
  • 19
    • 61649124483 scopus 로고    scopus 로고
    • MicroCT for developmental biology: A versatile tool for high-contrast 3D imaging at histological resolutions
    • Metscher BD. MicroCT for developmental biology: A versatile tool for high-contrast 3D imaging at histological resolutions. Dev Dyn 238: 632-640, 2009.
    • (2009) Dev Dyn , vol.238 , pp. 632-640
    • Metscher, B.D.1
  • 20
    • 33846856229 scopus 로고    scopus 로고
    • In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique
    • DOI 10.1088/0031-9155/51/23/008, PII S0031915506289899, 008
    • Namati E, Chon D, Thiesse J, Hoffman EA, de Ryk J, Ross A, McLennan G. In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique. Phys Med Biol 51: 6061-6075, 2006. (Pubitemid 46217649)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.23 , pp. 6061-6075
    • Namati, E.1    Chon, D.2    Thiesse, J.3    Hoffman, E.A.4    De Ryk, J.5    Ross, A.6    McLennan, G.7
  • 21
    • 33745830136 scopus 로고    scopus 로고
    • A brief update on lung stereology
    • DOI 10.1111/j.1365-2818.2006.01587.x
    • Ochs M. A brief update on lung stereology. J Microsc 222: 188-200, 2006. (Pubitemid 44035814)
    • (2006) Journal of Microscopy , vol.222 , Issue.3 , pp. 188-200
    • Ochs, M.1
  • 24
    • 0034088968 scopus 로고    scopus 로고
    • High resolution X-ray computed tomography: An emerging tool for small animal cancer research
    • Paulus MJ, Gleason SS, Kennel SJ, Hunsicker PR, Johnson DK. High resolution X-ray computed tomography: An emerging tool for small animal cancer research. Neoplasia 2: 62-70, 2000. (Pubitemid 30123181)
    • (2000) Neoplasia , vol.2 , Issue.1-2 , pp. 62-70
    • Paulus, M.J.1    Gleason, S.S.2    Kennel, S.J.3    Hunsicker, P.R.4    Johnson, D.K.5
  • 25
  • 26
    • 31144434642 scopus 로고    scopus 로고
    • Micro-computed tomography of the lungs and pulmonary-vascular system
    • DOI 10.1513/pats.200508-080DS
    • Ritman EL. Micro-computed tomography of the lungs and pulmonaryvascular system. Proc Am Thorac Soc 2: 477-480, 501, 2005. (Pubitemid 43128017)
    • (2005) Proceedings of the American Thoracic Society , vol.2 , Issue.6 , pp. 477-480
    • Ritman, E.L.1
  • 27
    • 0014794666 scopus 로고
    • A simple method for volumetry of organs in quantitative stereology
    • Scherle W. A simple method for volumetry of organs in quantitative stereology. Mikroskopie 26: 57-60, 1970.
    • (1970) Mikroskopie , vol.26 , pp. 57-60
    • Scherle, W.1
  • 28
  • 29
    • 0015156441 scopus 로고
    • Visualization of extracellular lining layer of lung alveoli by freeze-etching
    • Untersee P, Gil J, Weibel ER. Visualization of extracellular lining layer of lung alveoli by freeze-etching. Respir Physiol 13: 171-185, 1971.
    • (1971) Respir Physiol , vol.13 , pp. 171-185
    • Untersee, P.1    Gil, J.2    Weibel, E.R.3
  • 30
    • 0027377185 scopus 로고
    • Massive hemorrhage causes changes in morphometric parameters of lung capillaries and concentration of leukocytes in microvasculature
    • Vock R, Weibel ER. Massive hemorrhage causes changes in morphometric parameters of lung capillaries and concentration of leukocytes in microvasculature. Exp Lung Res 19: 559-577, 1993. (Pubitemid 23288822)
    • (1993) Experimental Lung Research , vol.19 , Issue.5 , pp. 559-577
    • Vock, R.1    Weibel, E.R.2
  • 31
    • 4544333724 scopus 로고    scopus 로고
    • Improved method of in vivo respiratory-gated micro-CT imaging
    • DOI 10.1088/0031-9155/49/17/023, PII S0031915504815197
    • Walters EB, Panda K, Bankson JA, Brown E, Cody DD. Improved method of in vivo respiratory-gated micro-CT imaging. Phys Med Biol 49: 4163-4172, 2004. (Pubitemid 39243001)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.17 , pp. 4163-4172
    • Walters, E.B.1    Panda, K.2    Bankson, J.A.3    Brown, E.4    Cody, D.D.5
  • 33
    • 0009924331 scopus 로고
    • Fixation of the lung by formalin steam in a controlled state of air inflation
    • Weibel ER, Vidone RA. Fixation of the lung by formalin steam in a controlled state of air inflation. Am Rev Respir Dis 84: 856-861, 1961.
    • (1961) Am Rev Respir Dis , vol.84 , pp. 856-861
    • Weibel, E.R.1    Vidone, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.