-
1
-
-
0034212337
-
Dosimetric evaluation of abutted fields using asymmetric collimators for treatment of head and neck
-
Saw C.B., Krishna K.V., Enke C.A., Hussey D.H. Dosimetric evaluation of abutted fields using asymmetric collimators for treatment of head and neck. Int. J. Radiat. Oncol. Biol. Phys. 47:2000;821-824
-
(2000)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.47
, pp. 821-824
-
-
Saw, C.B.1
Krishna, K.V.2
Enke, C.A.3
Hussey, D.H.4
-
2
-
-
0034125544
-
Dosimetric assessment of nonperfectly abutted fields using asymmetric collimators
-
Saw C.B., Hussey D.H. Dosimetric assessment of nonperfectly abutted fields using asymmetric collimators. Med. Dosim. 25:2000;23-26
-
(2000)
Med. Dosim.
, vol.25
, pp. 23-26
-
-
Saw, C.B.1
Hussey, D.H.2
-
3
-
-
0032054227
-
Junctioning of lateral and anterior fields in head and neck cancer: A dosimetric assessment of the monoisocentric technique (including reproducibility)
-
Zhu L., Kron T., Barnes K., Johansen S., O'Brien P. Junctioning of lateral and anterior fields in head and neck cancer A dosimetric assessment of the monoisocentric technique (including reproducibility). Int. J. Radiat. Oncol. Biol. Phys. 41:1998;227-232
-
(1998)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.41
, pp. 227-232
-
-
Zhu, L.1
Kron, T.2
Barnes, K.3
Johansen, S.4
O'Brien, P.5
-
4
-
-
0028203796
-
A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jaws
-
Klein E.E., Taylor M., Michaletz-Lorenz M., Zoeller D., Umfleet W. A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jaws. Int. J. Radiat. Oncol. Biol. Phys. 28:1994;753-760
-
(1994)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.28
, pp. 753-760
-
-
Klein, E.E.1
Taylor, M.2
Michaletz-Lorenz, M.3
Zoeller, D.4
Umfleet, W.5
-
5
-
-
0021241123
-
A simple isocentric technique for irradiation of the breast, chest wall and peripheral lymphatics
-
Podgorsak E.B., Gosselin M., Kim T.H., Freeman C.R. A simple isocentric technique for irradiation of the breast, chest wall and peripheral lymphatics. Br. J. Radiol. 57:1984;57-63
-
(1984)
Br. J. Radiol.
, vol.57
, pp. 57-63
-
-
Podgorsak, E.B.1
Gosselin, M.2
Kim, T.H.3
Freeman, C.R.4
-
6
-
-
0036079263
-
Abutment region dosimetry for the monoisocentric three-beam split field technique in the head and neck region using asymmetrical collimators
-
Abdel-Hakim K., Nishimura T., Takai M., Suzuki S., Sakahara H. Abutment region dosimetry for the monoisocentric three-beam split field technique in the head and neck region using asymmetrical collimators. Br. J. Radiol. 75:2002;428-434
-
(2002)
Br. J. Radiol.
, vol.75
, pp. 428-434
-
-
Abdel-Hakim, K.1
Nishimura, T.2
Takai, M.3
Suzuki, S.4
Sakahara, H.5
-
7
-
-
0032432332
-
The effect of independent collimator misalignment on the dosimetry of abutted half-beam blocked fields for the treatment of head and neck cancer
-
Rosenthal D.I., McDonough J., Kassaee A. The effect of independent collimator misalignment on the dosimetry of abutted half-beam blocked fields for the treatment of head and neck cancer. Radiother. Oncol. 49:1990;273-278
-
(1990)
Radiother. Oncol.
, vol.49
, pp. 273-278
-
-
Rosenthal, D.I.1
McDonough, J.2
Kassaee, A.3
-
8
-
-
0029062528
-
A method for delivering accurate and uniform radiation dosages to the head and neck with asymmetric collimators and a single isocenter
-
Sohn J.W., Suh J.H., Pohar S. A method for delivering accurate and uniform radiation dosages to the head and neck with asymmetric collimators and a single isocenter. Int. J. Radiat. Oncol. Biol. Phys. 32:1995;809-813
-
(1995)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.32
, pp. 809-813
-
-
Sohn, J.W.1
Suh, J.H.2
Pohar, S.3
-
9
-
-
0034565928
-
Decreasing the dosimetric effects of misalignment when using a mono-isocentric technique for irradiation of head and neck cancer
-
Fabrizio P.L., McCullough E.C., Foote R.L. Decreasing the dosimetric effects of misalignment when using a mono-isocentric technique for irradiation of head and neck cancer. Int. J. Radiat. Oncol. Biol. Phys. 48:2000;1623-1634
-
(2000)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.48
, pp. 1623-1634
-
-
Fabrizio, P.L.1
McCullough, E.C.2
Foote, R.L.3
-
10
-
-
0037376134
-
A three-field breast treatment technique with precise geometric matching using multileaf collimator-equipped linear accelerators
-
Lu X.Q., Sullivan S., Eggleston T. A three-field breast treatment technique with precise geometric matching using multileaf collimator-equipped linear accelerators. Int. J. Radiat. Oncol. Biol. Phys. 55:2003;1420-1431
-
(2003)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.55
, pp. 1420-1431
-
-
Lu, X.Q.1
Sullivan, S.2
Eggleston, T.3
-
13
-
-
0030901432
-
Consistent collimator overlaps in field matching with computer-controlled x-ray collimators
-
Lee P.C. Consistent collimator overlaps in field matching with computer-controlled x-ray collimators. Med. Dosim. 22:1997;59-61
-
(1997)
Med. Dosim.
, vol.22
, pp. 59-61
-
-
Lee, P.C.1
-
14
-
-
0003651542
-
Prescribing, recording and reporting photon beam therapy
-
Landberg T., Chavaudra J., Dobbs J., et al. Prescribing, recording and reporting photon beam therapy. ICRU Report. 50:1993
-
(1993)
ICRU Report
, vol.50
-
-
Landberg, T.1
Chavaudra, J.2
Dobbs, J.3
-
15
-
-
0038784427
-
Automatic feathering of split fields for step-and-shoot intensity modulated radiation therapy
-
Dogan N., Leybovich L.B., Sethi A., Emami B. Automatic feathering of split fields for step-and-shoot intensity modulated radiation therapy. Phys. Med. Bio. 48:2003;1133-1140
-
(2003)
Phys. Med. Bio.
, vol.48
, pp. 1133-1140
-
-
Dogan, N.1
Leybovich, L.B.2
Sethi, A.3
Emami, B.4
|