Volumn 25, Issue 1, 2000, Pages 23-26

Dosimetric assessment of nonperfectly abutted fields using asymmetric collimators

Author keywords

Abutted fields; Asymmetric collimation; Dosimetry; Radiation therapy

Indexed keywords

ARTICLE; COLLIMATOR; DOSIMETRY; LINEAR ACCELERATOR; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION FIELD;

EID: 0034125544     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(99)00037-0     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0023019507 scopus 로고
    • Dosimetry of asymmetric x-ray collimators
    • Khan F.M., Gerbi B.J., Deibel F.C. Dosimetry of asymmetric x-ray collimators. Med. Phys. 13:1986;936-941.
    • (1986) Med. Phys. , vol.13 , pp. 936-941
    • Khan, F.M.1    Gerbi, B.J.2    Deibel, F.C.3
  • 2
    • 0023881154 scopus 로고
    • Dose computations for asymmetric fields defined by independent jaws
    • Chui C., Mohan R., Fontenia D. Dose computations for asymmetric fields defined by independent jaws. Med. Phys. 15:1988;92-95.
    • (1988) Med. Phys. , vol.15 , pp. 92-95
    • Chui, C.1    Mohan, R.2    Fontenia, D.3
  • 3
    • 0023771635 scopus 로고
    • Analysis of tissue-maximum ratio/scatter-maximum ratio in asymmetrically collimated fields
    • Loshek D.D. Analysis of tissue-maximum ratio/scatter-maximum ratio in asymmetrically collimated fields. Med. Phys. 15:1988;672-682.
    • (1988) Med. Phys. , vol.15 , pp. 672-682
    • Loshek, D.D.1
  • 4
    • 0023931449 scopus 로고
    • Dosimetry characteristics of a 6 MV photon beam from a linear accelerator with asymmetric collimator jaws
    • Palta J.R., Ayyangar K.M., Suntharalingam N. Dosimetry characteristics of a 6 MV photon beam from a linear accelerator with asymmetric collimator jaws. Int. J. Radiat. Oncol. Biol. Phys. 14:1988;383-387.
    • (1988) Int. J. Radiat. Oncol. Biol. Phys. , vol.14 , pp. 383-387
    • Palta, J.R.1    Ayyangar, K.M.2    Suntharalingam, N.3
  • 5
    • 0027452170 scopus 로고
    • Independent collimator dosimetry for a dual photon energy linear accelerator
    • Slessinger E.D., Gerber R.L., Harms W.B., et al. Independent collimator dosimetry for a dual photon energy linear accelerator. Int. J. Radiat. Oncol. Biol. Phys. 27:1993;681-687.
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.27 , pp. 681-687
    • Slessinger, E.D.1    Gerber, R.L.2    Harms, W.B.3
  • 6
    • 0029317653 scopus 로고
    • Applications of asymmetric collimators of linear accelerators
    • Stern R.L., Rosenthal S.A., Doggett E.C., et al. Applications of asymmetric collimators of linear accelerators. Med. Dosim. 20:1995;95-98.
    • (1995) Med. Dosim. , vol.20 , pp. 95-98
    • Stern, R.L.1    Rosenthal, S.A.2    Doggett, E.C.3
  • 7
    • 0025296011 scopus 로고
    • A technique of treating local breast cancer using a single set-up point and asymmetric collimation
    • Rosenow U.F., Valentine E.S., Davis L.W. A technique of treating local breast cancer using a single set-up point and asymmetric collimation. Int. J. Radiat. Oncol. Biol. Phys. 19:1990;183-188.
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.19 , pp. 183-188
    • Rosenow, U.F.1    Valentine, E.S.2    Davis, L.W.3
  • 8
    • 0027373372 scopus 로고
    • Three-field isocentric breast irradiation using asymmetric jaws and a tilt board
    • Marshall M.G. Three-field isocentric breast irradiation using asymmetric jaws and a tilt board. Radiother. Oncol. 28:1993;228-232.
    • (1993) Radiother. Oncol. , vol.28 , pp. 228-232
    • Marshall, M.G.1
  • 9
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • Kutcher G.J., Coia L., Gillin M., et al. Comprehensive QA for radiation oncology Report of AAPM Radiation Therapy Committee Task Group 40 . Med. Phys. 21:1994;581-618.
    • (1994) Med. Phys. , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3
  • 10
    • 0030901432 scopus 로고
    • Consistent collimator overlaps in field matching with computer-controlled x-ray collimator
    • Lee P.C. Consistent collimator overlaps in field matching with computer-controlled x-ray collimator. Med. Dosim. 22:1977;59-61.
    • (1977) Med. Dosim. , vol.22 , pp. 59-61
    • Lee, P.C.1
  • 11
    • 0029062528 scopus 로고
    • A method for delivering accurate and uniform radiation dosages to the head and neck with asymmetric collimators and a single isocenter
    • Sohn J.W., Suh J.H., Pohar S. A method for delivering accurate and uniform radiation dosages to the head and neck with asymmetric collimators and a single isocenter. Int. J. Radiat. Oncol. Biol. Phys. 32:1995;809-813.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.32 , pp. 809-813
    • Sohn, J.W.1    Suh, J.H.2    Pohar, S.3
  • 12
    • 0032432332 scopus 로고    scopus 로고
    • The effect of independent collimator misalignment on the dosimetry of abutted half-beam blocked fields for the treatment of head and neck cancer
    • Rosenthal D.I., McDonough J., Kassaee A. The effect of independent collimator misalignment on the dosimetry of abutted half-beam blocked fields for the treatment of head and neck cancer. Radiother. Oncol. 49:1998;273-278.
    • (1998) Radiother. Oncol. , vol.49 , pp. 273-278
    • Rosenthal, D.I.1    McDonough, J.2    Kassaee, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.