메뉴 건너뛰기




Volumn , Issue , 2011, Pages 326-332

Integrated heaters for temperature control in disposable bioassay cartridges for use with portable, battery-operated instruments

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRICAL CONTACTS; ELECTRICAL INTERCONNECTIONS; ENERGY SOURCE; FINITE ELEMENT MODELS; FREQUENCY-DEPENDENT; INDUCTIVE HEATING; INJECTION MOLDED PLASTIC; INTEGRATED HEATER; MICROLITERS; OFF-THE-SHELF COMPONENTS; REACTION CHAMBERS; RESISTIVE HEATING; SURFACE MOUNT COMPONENTS; SURFACE MOUNT RESISTORS;

EID: 84055221989     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090085     Document Type: Conference Paper
Times cited : (3)

References (34)
  • 4
    • 33845686172 scopus 로고    scopus 로고
    • HIV viral load monitoring in resource-limited regions: Optional or necessary?
    • A. Calmy et al., "HIV viral load monitoring in resource-limited regions: optional or necessary?," Clin Infect Dis, vol. 44, no. 1, pp. 128-34, 2007.
    • (2007) Clin Infect Dis , vol.44 , Issue.1 , pp. 128-134
    • Calmy, A.1
  • 5
    • 33750851598 scopus 로고    scopus 로고
    • HIV-1 viral load assays for resource-limited settings
    • S. A. Fiscus et al., "HIV-1 viral load assays for resource-limited settings," PLoS Med, vol. 3, no. 10, p. e417, 2006.
    • (2006) PLoS Med , vol.3 , Issue.10
    • Fiscus, S.A.1
  • 6
    • 36049042515 scopus 로고    scopus 로고
    • Requirements for high impact diagnostics in the developing world
    • Nov.
    • M. Urdea et al., "Requirements for high impact diagnostics in the developing world," Nature, vol. 444 Suppl 1, pp. 73-79, Nov. 2006.
    • (2006) Nature , vol.444 , Issue.SUPPL. 1 , pp. 73-79
    • Urdea, M.1
  • 8
    • 33645844551 scopus 로고    scopus 로고
    • PCR microfluidic devices for DNA amplification
    • Jun.
    • C. Zhang, J. Xu, W. Ma, and W. Zheng, "PCR microfluidic devices for DNA amplification," Biotechnology Advances, vol. 24, no. 3, pp. 243-284, Jun. 2006.
    • (2006) Biotechnology Advances , vol.24 , Issue.3 , pp. 243-284
    • Zhang, C.1    Xu, J.2    Ma, W.3    Zheng, W.4
  • 9
    • 3042738385 scopus 로고    scopus 로고
    • Recent progress in microfluidic devices for nucleic acid and antibody assays
    • P. R. Selvaganapathy, E. T. Carlen, and C. H. Mastrangelo, "Recent progress in microfluidic devices for nucleic acid and antibody assays," Proceedings of the IEEE, vol. 91, no. 6, pp. 954-975, 2003.
    • (2003) Proceedings of the IEEE , vol.91 , Issue.6 , pp. 954-975
    • Selvaganapathy, P.R.1    Carlen, E.T.2    Mastrangelo, C.H.3
  • 10
    • 84055190253 scopus 로고    scopus 로고
    • Developing a point-of-care multiplexed diagnostic system for low-resource settings in developing countries
    • San Francisco, CA, March 25
    • J.L. Gerlach et al., "Developing a point-of-care multiplexed diagnostic system for low-resource settings in developing countries," presented at Molecular Medicine Tri-Conference, San Francisco, CA, March 25, 2008.
    • (2008) Presented at Molecular Medicine Tri-Conference
    • Gerlach, J.L.1
  • 11
    • 84855453661 scopus 로고    scopus 로고
    • HOT diagnostic technologies: Low-cost, pointof- care nucleic acid amplification using chemical heat to replace traditional heat sources
    • presented at, Washington, DC, April 12
    • P.D. LaBarrre et al., "HOT Diagnostic Technologies: Low-cost, pointof- care nucleic acid amplification using chemical heat to replace traditional heat sources," presented at 6th Annual World Health Care Congress, Washington, DC, April 12, 2009.
    • (2009) th Annual World Health Care Congress
    • Labarrre, P.D.1
  • 12
    • 84055193095 scopus 로고    scopus 로고
    • Affordable point-of-care viral RNA specimen processing for low-resource settings
    • San Jose, CA, April 22
    • D.S. Stevens et al., "Affordable point-of-care viral RNA specimen processing for low-resource settings," presented at AACC 42nd Annual Oak Ridge Conference, San Jose, CA, April 22, 2010.
    • (2010) Presented at AACC 42nd Annual Oak Ridge Conference
    • Stevens, D.S.1
  • 14
    • 0041837248 scopus 로고    scopus 로고
    • Integrating polymerase chain reaction valving and electrophoresis in a plastic device for bacterial detection
    • C.G. Koh, W. Tan, M. Zhao, A.J. Ricco, and Z.H. Fan, Integrating Polymerase Chain Reaction, Valving, and Electrophoresis in a Plastic Device for Bacterial Detection, Anal. Chem.,vol. 75, pp. 4591-4598, 2003.
    • (2003) Anal. Chem. , vol.75 , pp. 4591-4598
    • Koh, C.G.1    Tan, W.2    Zhao, M.3    Ricco, A.J.4    Fan, Z.H.5
  • 16
    • 0030815923 scopus 로고    scopus 로고
    • A branched DNA signal amplification assay for quantification of nucleic acid targets below 100 molecules/ml
    • M. L. Collins et al., others, "A branched DNA signal amplification assay for quantification of nucleic acid targets below 100 molecules/ml," Nucleic acids research, vol. 25, no. 15, p. 2979, 1997.
    • (1997) Nucleic Acids Research , vol.25 , Issue.15 , pp. 2979
    • Collins, M.L.1    Others, E.2
  • 18
    • 0032538386 scopus 로고    scopus 로고
    • An integrated nanoliter DNA analysis device
    • M. A. Burns et al., others, "An integrated nanoliter DNA analysis device," Science, vol. 282, no. 5388, pp. 484-487, 1998.
    • (1998) Science , vol.282 , Issue.5388 , pp. 484-487
    • Burns, M.A.1    Others, E.2
  • 20
    • 79954778134 scopus 로고    scopus 로고
    • Point-of-care nucleic acid testing for infectious diseases
    • In Press, Corrected Proof
    • A. Niemz, T. M. Ferguson, and D. S. Boyle, "Point-of-care nucleic acid testing for infectious diseases," Trends in Biotechnology, vol. In Press, Corrected Proof, 2011.
    • (2011) Trends in Biotechnology
    • Niemz, A.1    Ferguson, T.M.2    Boyle, D.S.3
  • 21
    • 77949801072 scopus 로고    scopus 로고
    • Microfluidic lab-on-a-foil for nucleic acid analysis based on isothermal recombinase polymerase amplification (RPA)
    • Apr.
    • S. Lutz et al., "Microfluidic lab-on-a-foil for nucleic acid analysis based on isothermal recombinase polymerase amplification (RPA)," Lab on a Chip, vol. 10, no. 7, pp. 887-893, Apr. 2010.
    • (2010) Lab on A Chip , vol.10 , Issue.7 , pp. 887-893
    • Lutz, S.1
  • 22
    • 1242351491 scopus 로고    scopus 로고
    • Integrated microfluidic devices
    • Apr.
    • D. Erickson and D. Li, "Integrated microfluidic devices," Analytica Chimica Acta, vol. 507, no. 1, pp. 11-26, Apr. 2004.
    • (2004) Analytica Chimica Acta , vol.507 , Issue.1 , pp. 11-26
    • Erickson, D.1    Li, D.2
  • 24
    • 0003784924 scopus 로고
    • 2nd Edition, School of Mechanical Engineering, Purdue University, New York, John Wiley and Sons
    • F.P. Incropera, D.P.DeWitt, Introduction to Heat Transfer, 2nd Edition, School of Mechanical Engineering, Purdue University, New York, John Wiley and Sons, 1990.
    • (1990) Introduction to Heat Transfer
    • Incropera, F.P.1    Dewitt, D.P.2
  • 29
    • 7544235802 scopus 로고    scopus 로고
    • A powerefficient thermocycler based on induction heating for DNA amplification by polymerase chain reaction
    • D. Pal, K. N. Mohan, H. S. Chandra, and V. Natarajan, "A powerefficient thermocycler based on induction heating for DNA amplification by polymerase chain reaction," Rev. Sci. Instrum., vol. 75, no. 9, 2004.
    • (2004) Rev. Sci. Instrum. , vol.75 , Issue.9
    • Pal, D.1    Mohan, K.N.2    Chandra, H.S.3    Natarajan, V.4
  • 30
    • 0036894566 scopus 로고    scopus 로고
    • A portable battery-operated chip thermocycler based on induction heating
    • Dec.
    • D. Pal and V. Venkataraman, "A portable battery-operated chip thermocycler based on induction heating," Sensors and Actuators A: Physical, vol. 102, no. 1-2, pp. 151-156, Dec. 2002.
    • (2002) Sensors and Actuators A: Physical , vol.102 , Issue.1-2 , pp. 151-156
    • Pal, D.1    Venkataraman, V.2
  • 31
    • 84055184442 scopus 로고    scopus 로고
    • Induction heating system topology review AN9012
    • "Induction Heating System Topology Review AN9012." Fairchild semiconductor, 2010.
    • (2010) Fairchild Semiconductor
  • 32
    • 0141886248 scopus 로고    scopus 로고
    • PDMS-glass hybrid microreactor array with embedded temperature control device. Application to cell-free protein synthesis
    • Nov.
    • T. Yamamoto, T. Fujii, and T. Nojima, "PDMS-glass hybrid microreactor array with embedded temperature control device. Application to cell-free protein synthesis," Lab on a Chip, vol. 2, no. 4, pp. 197-202, Nov. 2002.
    • (2002) Lab on A Chip , vol.2 , Issue.4 , pp. 197-202
    • Yamamoto, T.1    Fujii, T.2    Nojima, T.3
  • 33
    • 33645959228 scopus 로고    scopus 로고
    • Transparent polymeric cell culture chip with integrated temperature control and uniform media perfusion
    • Mar.
    • S. Petronis, M. Stangegaard, C. B. V. Christensen, and M. Dufva, "Transparent polymeric cell culture chip with integrated temperature control and uniform media perfusion," BioTechniques, vol. 40, no. 3, pp. 368-376, Mar. 2006.
    • (2006) BioTechniques , vol.40 , Issue.3 , pp. 368-376
    • Petronis, S.1    Stangegaard, M.2    Christensen, C.B.V.3    Dufva, M.4
  • 34
    • 77951985022 scopus 로고    scopus 로고
    • Embedded resistance wire as a heating element for temperature control in microbioreactors
    • May.
    • M. N. H. Z. Alam, D. Schäpper, and K. V. Gernaey, "Embedded resistance wire as a heating element for temperature control in microbioreactors," Journal of Micromechanics and Microengineering, vol. 20, no. 5, p. 055014, May. 2010.
    • (2010) Journal of Micromechanics and Microengineering , vol.20 , Issue.5 , pp. 055014
    • Alam, M.N.H.Z.1    Schäpper, D.2    Gernaey, K.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.