메뉴 건너뛰기




Volumn 20, Issue 5, 2010, Pages

Embedded resistance wire as a heating element for temperature control in microbioreactors

Author keywords

[No Author keywords available]

Indexed keywords

CONTENT-BASED; CORRECTIVE ACTIONS; DIRECT HEATING; MICRO-BIOREACTOR; OPERATING TEMPERATURE; PERFORMANCE ASSESSMENT; POLYDIMETHYLSILOXANE PDMS; REACTOR CHAMBER; RESISTANCE WIRE; SACCHAROMYCES CEREVISIAE; SET-POINT; TECHNICAL REALIZATION; TEMPERATURE DROPS; WORKING VOLUME;

EID: 77951985022     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/20/5/055014     Document Type: Article
Times cited : (14)

References (22)
  • 1
    • 33745017144 scopus 로고    scopus 로고
    • Differential gene expression profiles and real-time measurements of growth parameters in Saccharomyces cerevisiae grown in microliter-scale bioreactors equipped with internal stirring
    • DOI 10.1021/bp0504288
    • Boccazzi P, Zhang Z, Kurosawa K, Szita N, Bhattacharya S, Jensen K F and Sinskey A J 2006 Differential gene expression profiles and real-time measurements of growth parameters in Saccharomyces cerevisiae grown in microliter-scale bioreactors equipped with internal stirring Biotechnol. Prog. 22 710-7 (Pubitemid 43877438)
    • (2006) Biotechnology Progress , vol.22 , Issue.3 , pp. 710-717
    • Boccazzi, P.1    Zhang, Z.2    Kurosawa, K.3    Szita, N.4    Bhattacharya, S.5    Jensen, K.F.6    Sinskey, A.J.7
  • 4
    • 0442278178 scopus 로고    scopus 로고
    • Microbioreactor arrays with parametric control for high-throughput experimentation
    • Maharbiz M M, Holtz W J, Howe R T and Keasling J D 2004 Microbioreactor arrays with parametric control for high-throughput experimentation Biotechnol. Bioeng. 85 376-81
    • (2004) Biotechnol. Bioeng. , vol.85 , Issue.4 , pp. 376-381
    • Maharbiz, M.M.1    Holtz, W.J.2    Howe, R.T.3    Keasling, J.D.4
  • 5
    • 33747873393 scopus 로고    scopus 로고
    • Microbioreactor arrays with integrated mixers and fluid injectors for high throughput experimentation with pH and dissolved oxygen control
    • Lee H L, Bocazzi P, Ram R J and Sinskey A J 2006 Microbioreactor arrays with integrated mixers and fluid injectors for high throughput experimentation with pH and dissolved oxygen control Lab chip 6 1229-35
    • (2006) Lab Chip , vol.6 , Issue.9 , pp. 1229-1235
    • Lee, H.L.1    Bocazzi, P.2    Ram, R.J.3    Sinskey, A.J.4
  • 8
    • 29144435133 scopus 로고    scopus 로고
    • Microreaction technology in education: Miniaturized enzyme membrane reactor
    • DOI 10.1002/ceat.200500209
    • Muller D H, Liauw M A and Greiner L 2005 Microreaction technology in education: miniaturized enzyme membrane reactor Chem. Eng. Technol. 28 1569-71 (Pubitemid 41829476)
    • (2005) Chemical Engineering and Technology , vol.28 , Issue.12 , pp. 1569-1571
    • Muller, D.H.1    Liauw, M.A.2    Greiner, L.3
  • 9
    • 33645959228 scopus 로고    scopus 로고
    • Transparent polymeric cell culture chip with integrated temperature control and uniform media perfusion
    • DOI 10.2144/000112122
    • Petronis S, Stangegaard M, Christensen C B V and Dufva M 2006 Transparent polymeric cell culture chip with integrated temperature control and uniform media perfusion BioTechniques 40 368-76 (Pubitemid 46542628)
    • (2006) BioTechniques , vol.40 , Issue.3 , pp. 368-376
    • Petronis, S.1    Stangegaard, M.2    Christensen, C.B.V.3    Dufva, M.4
  • 12
    • 34547839765 scopus 로고    scopus 로고
    • Miniaturized PCR chips for nucleic acid amplification and analysis: Latest advances and future trends
    • DOI 10.1093/nar/gkm389
    • Zhang C and Xing D 2007 Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends Nucleic Acid Res. 35 4223-37 (Pubitemid 47244579)
    • (2007) Nucleic Acids Research , vol.35 , Issue.13 , pp. 4223-4237
    • Zhang, C.1    Xing, D.2
  • 13
    • 33745674743 scopus 로고    scopus 로고
    • Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes
    • 1-9
    • Neuzil P, Zhang C, Pipper J, Oh S and Zhuo L 2006 Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes Nucleic Acid Res. 34 e77 1-9
    • (2006) Nucleic Acid Res. , vol.34 , pp. 77
    • Neuzil, P.1    Zhang, C.2    Pipper, J.3    Oh, S.4    Zhuo, L.5
  • 14
    • 0141886248 scopus 로고    scopus 로고
    • PDMS-glass hybrid microreactor array with embedded temperature control device. Application to cell-free protein synthesis
    • DOI 10.1039/b205010b
    • Yamamoto T, Nojima T and Fujii T 2002 PDMS-Glass hybrid microreactor array with embedded temperature control device. Application to cell-free protein synthesis Lab Chip 2 197-202 (Pubitemid 37254479)
    • (2002) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.2 , Issue.4 , pp. 197-202
    • Yamamoto, T.1    Nojima, T.2    Fujii, T.3
  • 15
    • 36549018609 scopus 로고    scopus 로고
    • Short-term effects of benzalkonium chloride and atrazine on Elodea canadensis using a miniaturised microbioreactor system for an online monitoring of physiologic parameters
    • DOI 10.1016/j.ecoenv.2007.02.001, PII S0147651307000371
    • Vervliet-Scheebaum M, Ritzenthaler R, Normann J and Wagner E 2008 Short-term effects of Benzalkonium Chloride and Atrazine on Elodea canadensis using a miniaturised microbioreactor system for an online monitoring of physiologic parameters Ecotoxicol. Environ. Saf. 69 254-62 (Pubitemid 350181075)
    • (2008) Ecotoxicology and Environmental Safety , vol.69 , Issue.2 , pp. 254-262
    • Vervliet-Scheebaum, M.1    Ritzenthaler, R.2    Normann, J.3    Wagner, E.4
  • 16
    • 33845670864 scopus 로고    scopus 로고
    • A novel lead-wire-resistance compensation technique using two-wire resistance temperature detector
    • Maiti T K 2006 A novel lead-wire-resistance compensation technique using two-wire resistance temperature detector J. IEEE Sensors 6 1454-8
    • (2006) J. IEEE Sensors , vol.6 , Issue.6 , pp. 1454-1458
    • Maiti, T.K.1
  • 18
    • 65649090138 scopus 로고    scopus 로고
    • Ohm's law for a wire in contact with thermal reservoir
    • Madsen M J 2009 Ohm's law for a wire in contact with thermal reservoir Am. J. Phys. 77 516-9
    • (2009) Am. J. Phys. , vol.77 , Issue.6 , pp. 516-519
    • Madsen, M.J.1
  • 19
    • 36749013593 scopus 로고    scopus 로고
    • Heat and mass transfer analysis in direct contact membrane distillation
    • DOI 10.1016/j.desal.2007.05.019, PII S0011916407005826
    • Qtaishat M, Matsuura T, Kruczek B and Khayet M 2008 Heat and mass transfer analysis in direct contact membrane distillation Desalination 219 272-92 (Pubitemid 350199233)
    • (2008) Desalination , vol.219 , Issue.1-3 , pp. 272-292
    • Qtaishat, M.1    Matsuura, T.2    Kruczek, B.3    Khayet, M.4
  • 20
    • 64549142361 scopus 로고    scopus 로고
    • Effects of temperature, pH and sugar concentration on the growth parameters of Saccharomyces cerevisiae, S. kudriavzevii and their interspecific hybrid
    • Arroyo-Lopez F N, Orlic S, Querol A and Barrio E 2009 Effects of temperature, pH and sugar concentration on the growth parameters of Saccharomyces cerevisiae, S. kudriavzevii and their interspecific hybrid J. Food Microbiol. 131 120-7
    • (2009) J. Food Microbiol. , vol.131 , Issue.2-3 , pp. 120-127
    • Arroyo-Lopez, F.N.1    Orlic, S.2    Querol, A.3    Barrio, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.