메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1001-1004

Breath gas analysis for estimating physiological processes using anesthetic monitoring as a prototypic example

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC OUTPUT; CLINICAL SETTINGS; CLINICAL STATE; NON-INVASIVE; NOVEL METHODOLOGY; PHYSIOLOGICAL MODELING; PHYSIOLOGICAL PROCESS; POTENTIAL APPLICATIONS; SIMULATION-BASED; TARGET SITES; TRACE-GASES;

EID: 84055217643     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090232     Document Type: Conference Paper
Times cited : (15)

References (12)
  • 3
    • 0032720378 scopus 로고    scopus 로고
    • Predicted sevoflurane partial pressure in the brain with an uptake and distribution model comparison with the measured value in internal jugular vein blood
    • M. Nakamura, Y. Sanjo, and K. Ikeda, "Predicted sevoflurane partial pressure in the brain with an uptake and distribution model comparison with the measured value in internal jugular vein blood," J. Clin. Monit. Comput., vol. 15, pp. 299-305, 1999.
    • (1999) J. Clin. Monit. Comput. , vol.15 , pp. 299-305
    • Nakamura, M.1    Sanjo, Y.2    Ikeda, K.3
  • 4
    • 34147142367 scopus 로고    scopus 로고
    • On-line monitoring of end-tidal propofol concentration in anesthetized patients
    • A. Takita, K. Masui, and T. Kazama, "On-line monitoring of end-tidal propofol concentration in anesthetized patients," Anesthesiology, vol. 106, pp. 659-664, 2007.
    • (2007) Anesthesiology , vol.106 , pp. 659-664
    • Takita, A.1    Masui, K.2    Kazama, T.3
  • 5
    • 0019444689 scopus 로고
    • The xtended Kalman filter as a pulmonary blood flow estimator
    • O. Brovko, D. M. Wiberg, L. Arena, and J. W. Bellville, "The xtended Kalman filter as a pulmonary blood flow estimator," Automatica, vol. 17, pp. 213-220, 1981.
    • (1981) Automatica , vol.17 , pp. 213-220
    • Brovko, O.1    Wiberg, D.M.2    Arena, L.3    Bellville, J.W.4
  • 6
    • 0030005208 scopus 로고    scopus 로고
    • Sevoflurane. A review of its pharmacodynamic and pharmacokinetic properties and its clinical use in general anaesthesia
    • S. S. Patel and K. L. Goa, "Sevoflurane. A review of its pharmacodynamic and pharmacokinetic properties and its clinical use in general anaesthesia," Drugs, vol. 51, pp. 658-700, 1996.
    • (1996) Drugs , vol.51 , pp. 658-700
    • Patel, S.S.1    Goa, K.L.2
  • 8
    • 0022656769 scopus 로고
    • Determination and prediction of tissue-gas partition coefficients
    • V. Fiserova-Bergerova and M. L. Diaz, "Determination and prediction of tissue-gas partition coefficients," Int. Arch. Occup. Environ. Health, vol. 58, pp. 75-87, 1986.
    • (1986) Int. Arch. Occup. Environ. Health , vol.58 , pp. 75-87
    • Fiserova-Bergerova, V.1    Diaz, M.L.2
  • 10
    • 23844494086 scopus 로고    scopus 로고
    • Marginalized particle filters for mixed linear/nonlinear state-space models
    • T. Schön, F. Gustafsson, and P.-J. Nordlund, "Marginalized particle filters for mixed linear/nonlinear state-space models," IEEE Trans. Signal Processing, vol. 53, pp. 2279-2289, 2005.
    • (2005) IEEE Trans. Signal Processing , vol.53 , pp. 2279-2289
    • Schön, T.1    Gustafsson, F.2    Nordlund, P.-J.3
  • 11
    • 0027580559 scopus 로고
    • A novel approach to nonlinear/non-Gaussian Bayesian state estimation
    • N. J. Gordon, D. J. Salmond, and A. F. M. Smith, "A novel approach to nonlinear/non-Gaussian Bayesian state estimation," IEE Proceedings F, vol. 140, pp. 107-113, 1993.
    • (1993) IEE Proceedings F , vol.140 , pp. 107-113
    • Gordon, N.J.1    Salmond, D.J.2    Smith, A.F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.