-
2
-
-
68249089213
-
Isoprene and acetone concentration profiles during exercise on an ergometer
-
16pp
-
J. King, A. Kupferthaler, K. Unterkofler, H. Koc, S. Teschl, G. Teschl, W. Miekisch, J. Schubert, H. Hinterhuber, and A. Amann, "Isoprene and acetone concentration profiles during exercise on an ergometer," J. Breath Res., vol. 3, p. 027006 (16pp), 2009.
-
(2009)
J. Breath Res.
, vol.3
, pp. 027006
-
-
King, J.1
Kupferthaler, A.2
Unterkofler, K.3
Koc, H.4
Teschl, S.5
Teschl, G.6
Miekisch, W.7
Schubert, J.8
Hinterhuber, H.9
Amann, A.10
-
3
-
-
0032720378
-
Predicted sevoflurane partial pressure in the brain with an uptake and distribution model comparison with the measured value in internal jugular vein blood
-
M. Nakamura, Y. Sanjo, and K. Ikeda, "Predicted sevoflurane partial pressure in the brain with an uptake and distribution model comparison with the measured value in internal jugular vein blood," J. Clin. Monit. Comput., vol. 15, pp. 299-305, 1999.
-
(1999)
J. Clin. Monit. Comput.
, vol.15
, pp. 299-305
-
-
Nakamura, M.1
Sanjo, Y.2
Ikeda, K.3
-
4
-
-
34147142367
-
On-line monitoring of end-tidal propofol concentration in anesthetized patients
-
A. Takita, K. Masui, and T. Kazama, "On-line monitoring of end-tidal propofol concentration in anesthetized patients," Anesthesiology, vol. 106, pp. 659-664, 2007.
-
(2007)
Anesthesiology
, vol.106
, pp. 659-664
-
-
Takita, A.1
Masui, K.2
Kazama, T.3
-
5
-
-
0019444689
-
The xtended Kalman filter as a pulmonary blood flow estimator
-
O. Brovko, D. M. Wiberg, L. Arena, and J. W. Bellville, "The xtended Kalman filter as a pulmonary blood flow estimator," Automatica, vol. 17, pp. 213-220, 1981.
-
(1981)
Automatica
, vol.17
, pp. 213-220
-
-
Brovko, O.1
Wiberg, D.M.2
Arena, L.3
Bellville, J.W.4
-
6
-
-
0030005208
-
Sevoflurane. A review of its pharmacodynamic and pharmacokinetic properties and its clinical use in general anaesthesia
-
S. S. Patel and K. L. Goa, "Sevoflurane. A review of its pharmacodynamic and pharmacokinetic properties and its clinical use in general anaesthesia," Drugs, vol. 51, pp. 658-700, 1996.
-
(1996)
Drugs
, vol.51
, pp. 658-700
-
-
Patel, S.S.1
Goa, K.L.2
-
7
-
-
0141792975
-
Sevoflurane in exhaled air of operating room personnel
-
G. Summer, P. Lirk, K. Hoerauf, U. Riccabona, F. Bodrogi, H. Raifer, M. Deibl, J. Rieder, and W. Schobersberger, "Sevoflurane in exhaled air of operating room personnel," Anesth. Analg., vol. 97, pp. 1070-1073, 2003.
-
(2003)
Anesth. Analg.
, vol.97
, pp. 1070-1073
-
-
Summer, G.1
Lirk, P.2
Hoerauf, K.3
Riccabona, U.4
Bodrogi, F.5
Raifer, H.6
Deibl, M.7
Rieder, J.8
Schobersberger, W.9
-
8
-
-
0022656769
-
Determination and prediction of tissue-gas partition coefficients
-
V. Fiserova-Bergerova and M. L. Diaz, "Determination and prediction of tissue-gas partition coefficients," Int. Arch. Occup. Environ. Health, vol. 58, pp. 75-87, 1986.
-
(1986)
Int. Arch. Occup. Environ. Health
, vol.58
, pp. 75-87
-
-
Fiserova-Bergerova, V.1
Diaz, M.L.2
-
10
-
-
23844494086
-
Marginalized particle filters for mixed linear/nonlinear state-space models
-
T. Schön, F. Gustafsson, and P.-J. Nordlund, "Marginalized particle filters for mixed linear/nonlinear state-space models," IEEE Trans. Signal Processing, vol. 53, pp. 2279-2289, 2005.
-
(2005)
IEEE Trans. Signal Processing
, vol.53
, pp. 2279-2289
-
-
Schön, T.1
Gustafsson, F.2
Nordlund, P.-J.3
-
11
-
-
0027580559
-
A novel approach to nonlinear/non-Gaussian Bayesian state estimation
-
N. J. Gordon, D. J. Salmond, and A. F. M. Smith, "A novel approach to nonlinear/non-Gaussian Bayesian state estimation," IEE Proceedings F, vol. 140, pp. 107-113, 1993.
-
(1993)
IEE Proceedings F
, vol.140
, pp. 107-113
-
-
Gordon, N.J.1
Salmond, D.J.2
Smith, A.F.M.3
|