메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4038-4041

Improvements in design of spectra of multisine and binary excitation signals for multi-frequency bioimpedance measurement

Author keywords

[No Author keywords available]

Indexed keywords

AMPLITUDE SPECTRA; BINARY SIGNALS; BINARY WAVEFORMS; BIOIMPEDANCE MEASUREMENT; BIOLOGIC CELL; BIOLOGICAL OBJECTS; BROADBAND EXCITATION; CONTACTLESS MEASUREMENT; EXCITATION SIGNALS; FAST MEASUREMENT; FREQUENCY COMPONENTS; GLASS CAPILLARIES; IMPEDANCE SPECTROSCOPY; IMPEDANCE SPECTRUM; IN-LINE MEASUREMENTS; MICRO-FLUIDIC DEVICES; MULTI FREQUENCY; MULTISINE; OUTER SURFACE; SEGMENTED FLOW; THIN-WALLED;

EID: 84055176196     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091003     Document Type: Conference Paper
Times cited : (10)

References (17)
  • 2
    • 76949103411 scopus 로고    scopus 로고
    • Using capacitance measurements in EWOD devices to identify fluid composition and control droplet mixing
    • M. J. Schertzer, R. Ben-Mrad and P. E. Sullivan, "Using capacitance measurements in EWOD devices to identify fluid composition and control droplet mixing," Sensors Actuators B: Chem., vol. 145, pp. 340-347, 2010.
    • (2010) Sensors Actuators B: Chem , vol.145 , pp. 340-347
    • Schertzer, M.J.1    Ben-Mrad, R.2    Sullivan, P.E.3
  • 4
    • 0141886232 scopus 로고    scopus 로고
    • The intensification of rapid reactions in multiphase systems using slug flow in capillaries
    • J. R. Burns and C. Ramshaw, "The intensification of rapid reactions in multiphase systems using slug flow in capillaries", Lab Chip, vol. 1, pp. 10-15, 2001.
    • (2001) Lab Chip , vol.1 , pp. 10-15
    • Burns, J.R.1    Ramshaw, C.2
  • 5
    • 77953127627 scopus 로고    scopus 로고
    • Development of a four electrode sensor array for impedance spectroscopy in high content screenings of fermentation processes
    • M. C. Hofmann, M. Funke, J. Büchs, W. Mokwa and U. Schnakenberg, "Development of a four electrode sensor array for impedance spectroscopy in high content screenings of fermentation processes," Sensors Actuators B: Chem., vol. 147, pp. 93-99, 2010.
    • (2010) Sensors Actuators B: Chem , vol.147 , pp. 93-99
    • Hofmann, M.C.1    Funke, M.2    Büchs, J.3    Mokwa, W.4    Schnakenberg, U.5
  • 7
    • 0033101199 scopus 로고    scopus 로고
    • Electric impedance spectroscopy using microchannels with integrated metal electrodes
    • H. E. Ayliffe, A. B. Frazier and R. D. Rabbitt, "Electric impedance spectroscopy using microchannels with integrated metal electrodes," J. Microelectromech. Syst., vol. 8, pp. 50-57, 1999.
    • (1999) J. Microelectromech. Syst , vol.8 , pp. 50-57
    • Ayliffe, H.E.1    Frazier, A.B.2    Rabbitt, R.D.3
  • 8
    • 34047102832 scopus 로고    scopus 로고
    • A microfluidic device for impedance spectroscopy analysis of biological samples
    • C. Iliescu, D. P. Poenar, M. Carp and F. C. Loe, "A microfluidic device for impedance spectroscopy analysis of biological samples," Sensors Actuators B: Chem., vol. 123, pp. 168-176, 2007.
    • (2007) Sensors Actuators B: Chem , vol.123 , pp. 168-176
    • Iliescu, C.1    Poenar, D.P.2    Carp, M.3    Loe, F.C.4
  • 10
    • 42549129169 scopus 로고    scopus 로고
    • Hydrophobic coating of microfluidic chips structured by SU-8 polymer for segmented flow operation
    • J. T. Schumacher, A. Grodrian, C. Kremin, M. Hoffmann and J. Metze, "Hydrophobic coating of microfluidic chips structured by SU-8 polymer for segmented flow operation," J. Micromech. Microeng., vol. 18, pp. 055019, 2008.
    • (2008) J. Micromech. Microeng , vol.18 , pp. 055019
    • Schumacher, J.T.1    Grodrian, A.2    Kremin, C.3    Hoffmann, M.4    Metze, J.5
  • 13
    • 0031257547 scopus 로고    scopus 로고
    • Multitone signals with low crest factor
    • M. Friese, "Multitone signals with low crest factor," IEEE Trans on Communications, vol. 45, no. 10: pp. 1338-1344, 1997.
    • (1997) IEEE Trans on Communications , vol.45 , Issue.10 , pp. 1338-1344
    • Friese, M.1
  • 14
    • 0025867576 scopus 로고
    • Design and application of non-binary low peak factor signals for system dynamic measurement
    • Edinburgh, UK
    • D. Rees, D. L. Jones, "Design and application of non-binary low peak factor signals for system dynamic measurement," in Proc. Int. Conference on Control, Edinburgh, UK, 1991, pp. 644-650.
    • (1991) Proc. Int. Conference on Control , pp. 644-650
    • Rees, D.1    Jones, D.L.2
  • 16
    • 77749306444 scopus 로고    scopus 로고
    • Waveform synthesis of multi-frequency sinusoids with 2nth primary harmonics based on Walsh functions
    • Bejing, China
    • Y. Yang, J. Wang, Z. Gao, D. Liand J. Wang, "Waveform synthesis of multi-frequency sinusoids with 2nth primary harmonics based on Walsh functions," in Proc. IEEE Biomedical Circuits and Systems Conference, Bejing, China, 2009, pp. 129-132.
    • (2009) Proc. IEEE Biomedical Circuits and Systems Conference , pp. 129-132
    • Yang, Y.1    Wang, J.2    Gao, Z.3    Liand J Wang, D.4
  • 17
    • 0018543673 scopus 로고
    • Synthesis of discrete-interval binary signals with specified Fourier amplitude spectra
    • A. v.d. Bos and R. Krol, "Synthesis of discrete-interval binary signals with specified Fourier amplitude spectra," Int J Control, vol. 30, pp. 871-884, 1979.
    • (1979) Int J Control , vol.30 , pp. 871-884
    • Bos, A.V.D.1    Krol, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.