메뉴 건너뛰기




Volumn 30, Issue 2, 2012, Pages 178-184

Augmentation of peri-implant bone improves implant stability: Quantification using simulated bone loss

Author keywords

bone augmentation; bone loss; micro finite element (micro FE) analysis; peri implant bone quality

Indexed keywords

ARTICLE; FINITE ELEMENT ANALYSIS; FRACTURE FIXATION; HUMAN; HUMERUS HEAD; IMPLANT; MODEL; OSTEOLYSIS; OSTEOPOROSIS; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SIMULATION; VALIDATION PROCESS;

EID: 83855160895     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21532     Document Type: Article
Times cited : (13)

References (31)
  • 1
    • 0028799124 scopus 로고
    • The worldwide problem of osteoporosis: Insights afforded by epidemiology
    • Riggs BL, Melton LJ III., 1995. The worldwide problem of osteoporosis: insights afforded by epidemiology. Bone 17 (5 Suppl): 505S-511S.
    • (1995) Bone , vol.17 , Issue.5 SUPPL.
    • Riggs, B.L.1    Melton III, L.J.2
  • 2
    • 26944439116 scopus 로고    scopus 로고
    • The challenge: Fracture treatment in osteoporotic bone
    • DOI 10.1007/s00198-004-1766-3
    • Schneider E, Goldhahn J, Burckhardt P,. 2005. The challenge: fracture treatment in osteoporotic bone. Osteoporos Int 16 (Suppl 2): S1-S2. (Pubitemid 46232114)
    • (2005) Osteoporosis International , vol.16 , Issue.SUPPL. 2
    • Schneider, E.1    Goldhahn, J.2    Burckhardt, P.3
  • 3
    • 26244432251 scopus 로고    scopus 로고
    • Osteoporotic fractures of the proximal humerus, pelvis, and ankle: Epidemiology and diagnosis
    • DOI 10.1016/j.jbspin.2004.04.002, PII S1297319X04000983
    • Guggenbuhl P, Meadeb J, Chalès G,. 2005. Osteoporotic fractures of the proximal humerus, pelvis, and ankle: epidemiology and diagnosis. Joint Bone Spine 72: 372-375. (Pubitemid 41415823)
    • (2005) Joint Bone Spine , vol.72 , Issue.5 , pp. 372-375
    • Guggenbuhl, P.1    Meadeb, J.2    Chales, G.3
  • 4
    • 77955658258 scopus 로고    scopus 로고
    • Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft
    • Mathison C, Chaudhary R, Beaupre L, et al. 2010. Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft. Clin Biomech 25: 642-646.
    • (2010) Clin Biomech , vol.25 , pp. 642-646
    • Mathison, C.1    Chaudhary, R.2    Beaupre, L.3
  • 5
    • 46749109567 scopus 로고    scopus 로고
    • Influence of thread design on pedicle screw fixation: Laboratory investigation
    • DOI 10.3171/SPI/2008/9/7/090
    • Krenn MH, Piotrowski WP, Penzkofer R, et al. 2008. Influence of thread design on pedicle screw fixation. Laboratory investigation. J Neurosurg Spine 9: 90-95. (Pubitemid 351948782)
    • (2008) Journal of Neurosurgery: Spine , vol.9 , Issue.1 , pp. 90-95
    • Krenn, M.H.1    Piotrowski, W.P.2    Penzkofer, R.3    Augat, P.4
  • 6
    • 4844225504 scopus 로고    scopus 로고
    • Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    • DOI 10.1016/j.orthres.2004.04.001, PII S0736026604001068
    • Seebeck J, Goldhahn J, Städele H, et al. 2004. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 22: 1237-1242. (Pubitemid 39317913)
    • (2004) Journal of Orthopaedic Research , vol.22 , Issue.6 , pp. 1237-1242
    • Seebeck, J.1    Goldhahn, J.2    Stadele, H.3    Messmer, P.4    Morlock, M.M.5    Schneider, E.6
  • 7
    • 62849101873 scopus 로고    scopus 로고
    • Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?
    • Helwig P, Bahrs C, Epple B, et al. 2009. Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? Acta Orthop 80: 92-96.
    • (2009) Acta Orthop , vol.80 , pp. 92-96
    • Helwig, P.1    Bahrs, C.2    Epple, B.3
  • 9
    • 78149281362 scopus 로고    scopus 로고
    • Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation
    • Stadelmann VA, Bretton E, Terrier A, et al. 2010. Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation. J Biomech 43: 2869-2874.
    • (2010) J Biomech , vol.43 , pp. 2869-2874
    • Stadelmann, V.A.1    Bretton, E.2    Terrier, A.3
  • 10
    • 33744920556 scopus 로고    scopus 로고
    • Parathyroid hormone 1-34 enhances titanium implant anchorage in low-density trabecular bone: A correlative micro-computed tomographic and biomechanical analysis
    • DOI 10.1016/j.bone.2006.02.004, PII S8756328206002614
    • Gabet Y, Müller R, Levy J, et al. 2006. Parathyroid hormone 1-34 enhances titanium implant anchorage in low-density trabecular bone: a correlative micro-computed tomographic and biomechanical analysis. Bone 39: 276-282. (Pubitemid 43851377)
    • (2006) Bone , vol.39 , Issue.2 , pp. 276-282
    • Gabet, Y.1    Muller, R.2    Levy, J.3    Dimarchi, R.4    Chorev, M.5    Bab, I.6    Kohavi, D.7
  • 11
    • 67749148278 scopus 로고    scopus 로고
    • Temperature evaluation during PMMA screw augmentation in osteoporotic bone-an in vitro study about the risk of thermal necrosis in human femoral heads
    • Boner V, Kuhn P, Mendel T, et al. 2009. Temperature evaluation during PMMA screw augmentation in osteoporotic bone-an in vitro study about the risk of thermal necrosis in human femoral heads. J Biomed Mater Res B Appl Biomater 90: 842-848.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.90 , pp. 842-848
    • Boner, V.1    Kuhn, P.2    Mendel, T.3
  • 13
    • 3342906939 scopus 로고    scopus 로고
    • The bisphosphonate pamidronate on the surface of titanium stimulates bone formation around tibial implants in rats
    • DOI 10.1016/j.biomaterials.2004.02.072, PII S0142961204002352
    • Kajiwara H, Yamaza T, Yoshinari M, et al. 2005. The bisphosphonate pamidronate on the surface of titanium stimulates bone formation around tibial implants in rats. Biomaterials 26: 581-587. (Pubitemid 38988300)
    • (2005) Biomaterials , vol.26 , Issue.6 , pp. 581-587
    • Kajiwara, H.1    Yamaza, T.2    Yoshinari, M.3    Goto, T.4    Iyama, S.5    Atsuta, I.6    Kido, M.A.7    Tanaka, T.8
  • 14
    • 53749087447 scopus 로고    scopus 로고
    • Implants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study
    • Stadelmann VA, Gauthier O, Terrier A, et al. 2008. Implants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study. Eur Cell Mater 16: 10-16.
    • (2008) Eur Cell Mater , vol.16 , pp. 10-16
    • Stadelmann, V.A.1    Gauthier, O.2    Terrier, A.3
  • 15
    • 79960590735 scopus 로고    scopus 로고
    • Implant stability is affected by local bone microstructural quality
    • Wirth AJ, Goldhahn J, Flaig C, et al. Implant stability is affected by local bone microstructural quality. Bone. 49: 473-478.
    • Bone. , vol.49 , pp. 473-478
    • Wirth, A.J.1    Goldhahn, J.2    Flaig, C.3
  • 16
    • 0033047422 scopus 로고    scopus 로고
    • Direct three-dimensional morphometric analysis of human cancellous bone: Microstructural data from spine, femur, iliac crest, and calcaneus
    • DOI 10.1359/jbmr.1999.14.7.1167
    • Hildebrand T, Laib A, Müller R, et al. 1999. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res 14: 1167-1174. (Pubitemid 29314060)
    • (1999) Journal of Bone and Mineral Research , vol.14 , Issue.7 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Muller, R.3    Dequeker, J.4    Ruegsegger, P.5
  • 17
    • 26944496131 scopus 로고    scopus 로고
    • Long-term prediction of three-dimensional bone architecture in simulations of pre-, peri- and post-menopausal microstructural bone remodeling
    • DOI 10.1007/s00198-004-1701-7
    • Müller R,. 2005. Long-term prediction of three-dimensional bone architecture in simulations of pre-, peri- and post-menopausal microstructural bone remodeling. Osteoporos Int 16 (Suppl 2): S25-S35. (Pubitemid 46232118)
    • (2005) Osteoporosis International , vol.16 , Issue.SUPPL. 2
    • Muller, R.1
  • 18
    • 0026216595 scopus 로고
    • Age-related changes in resorption cavity characteristics in human trabecular bone
    • Croucher PI, Garrahan NJ, Mellish RW, et al. 1991. Age-related changes in resorption cavity characteristics in human trabecular bone. Osteoporos Int 1: 257-261.
    • (1991) Osteoporos Int , vol.1 , pp. 257-261
    • Croucher, P.I.1    Garrahan, N.J.2    Mellish, R.W.3
  • 20
    • 43149096685 scopus 로고    scopus 로고
    • Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method
    • MacNeil JA, Boyd SK,. 2008. Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method. Bone 42: 1203-1213.
    • (2008) Bone , vol.42 , pp. 1203-1213
    • MacNeil, J.A.1    Boyd, S.K.2
  • 22
    • 27944449749 scopus 로고    scopus 로고
    • In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    • DOI 10.1210/jc.2005-1258
    • Boutroy S, Bouxsein ML, Munoz F, et al. 2005. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J Clin Endocrinol Metab 90: 6508-6515. (Pubitemid 41759306)
    • (2005) Journal of Clinical Endocrinology and Metabolism , vol.90 , Issue.12 , pp. 6508-6515
    • Boutroy, S.1    Bouxsein, M.L.2    Munoz, F.3    Delmas, P.D.4
  • 23
    • 77950928665 scopus 로고    scopus 로고
    • Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck
    • Chen H, Zhou X, Shoumura S, et al. 2010. Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck. Osteoporos Int 21: 627-636.
    • (2010) Osteoporos Int , vol.21 , pp. 627-636
    • Chen, H.1    Zhou, X.2    Shoumura, S.3
  • 24
    • 1542346315 scopus 로고    scopus 로고
    • The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent error loads
    • DOI 10.1016/j.bone.2003.12.001, PII S8756328203004551
    • Homminga J, van Rietbergen B, Lochmüller EM, et al. 2004. The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent "error" loads. Bone 34: 510-516. (Pubitemid 38314915)
    • (2004) Bone , vol.34 , Issue.3 , pp. 510-516
    • Homminga, J.1    Van-Rietbergen, B.2    Lochmuller, E.M.3    Weinans, H.4    Eckstein, F.5    Huiskes, R.6
  • 26
    • 0003910686 scopus 로고    scopus 로고
    • 2nd ed. Cambridge Solid State Science Series. Cambridge: Cambridge University Press. p, 510.
    • Gibson LJ, Ashby MF,. 1997. Cellular solids: structure and properties, 2nd ed. Cambridge Solid State Science Series. Cambridge: Cambridge University Press. p xviii, 510.
    • (1997) Cellular Solids: Structure and Properties
    • Gibson, L.J.1    Ashby, M.F.2
  • 28
    • 33845961684 scopus 로고    scopus 로고
    • A biomechanical perspective on bone quality
    • DOI 10.1016/j.bone.2006.06.001, PII S8756328206005552
    • Hernandez CJ, Keaveny TM,. 2006. A biomechanical perspective on bone quality. Bone 39: 1173-1181. (Pubitemid 44827914)
    • (2006) Bone , vol.39 , Issue.6 , pp. 1173-1181
    • Hernandez, C.J.1    Keaveny, T.M.2
  • 29
    • 77953384909 scopus 로고    scopus 로고
    • Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae
    • Gabet Y, Kohavi D, Voide R, et al. 2010. Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae. J Bone Miner Res 25: 575-583.
    • (2010) J Bone Miner Res , vol.25 , pp. 575-583
    • Gabet, Y.1    Kohavi, D.2    Voide, R.3
  • 30
    • 77952009543 scopus 로고    scopus 로고
    • Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses
    • Wirth AJ, Mueller TL, Vereecken W, et al. 2010. Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses. Arch Appl Mech 80: 513-525.
    • (2010) Arch Appl Mech , vol.80 , pp. 513-525
    • Wirth, A.J.1    Mueller, T.L.2    Vereecken, W.3
  • 31
    • 79955602719 scopus 로고    scopus 로고
    • Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures
    • Röderer G, Gebhard F, Krischak G, et al. 2011. Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int Orthop. 35: 535-541.
    • (2011) Int Orthop. , vol.35 , pp. 535-541


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.