메뉴 건너뛰기




Volumn 6, Issue 12, 2011, Pages

Estimation of individual muscle force using elastography

Author keywords

[No Author keywords available]

Indexed keywords

ABDUCTOR DIGITI MINIMI MUSCLE; ACCURACY; ADULT; ARTICLE; CONTROLLED STUDY; ELASTOGRAPHY; ELECTRODE; ELECTROMYOGRAPHY; ERGOMETRY; FIRST DORSAL INTEROSSEOUS MUSCLE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; MUSCLE CELL; MUSCLE FORCE; MUSCLE ISOMETRIC CONTRACTION; NORMAL HUMAN; SHEAR STRESS; SKELETAL MUSCLE; TORQUE; VOLUNTEER; YOUNG MODULUS; BIOMECHANICS; METHODOLOGY; PHYSIOLOGY;

EID: 83755188198     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0029261     Document Type: Article
Times cited : (160)

References (28)
  • 2
    • 1642337026 scopus 로고    scopus 로고
    • The extraction of neural strategies from the surface EMG
    • Farina D, Merletti R, Enoka RM, (2004) The extraction of neural strategies from the surface EMG. J ApplPhysiol 96: 1486-1495.
    • (2004) J ApplPhysiol , vol.96 , pp. 1486-1495
    • Farina, D.1    Merletti, R.2    Enoka, R.M.3
  • 3
    • 78651097507 scopus 로고    scopus 로고
    • Can muscle coordination be precisely studied by surface electromyography?
    • Hug F, (2011) Can muscle coordination be precisely studied by surface electromyography? J ElectromyogrKinesiol 21: 1-12.
    • (2011) J ElectromyogrKinesiol , vol.21 , pp. 1-12
    • Hug, F.1
  • 4
    • 8644285417 scopus 로고    scopus 로고
    • Neuromusculoskeletal modeling: estimation of muscle forces and joint moments and movements from measurements of neural command
    • Buchanan TS, Lloyd DG, Manal K, Besier TF, (2004) Neuromusculoskeletal modeling: estimation of muscle forces and joint moments and movements from measurements of neural command. J ApplBiomech 20: 367-395.
    • (2004) J ApplBiomech , vol.20 , pp. 367-395
    • Buchanan, T.S.1    Lloyd, D.G.2    Manal, K.3    Besier, T.F.4
  • 5
    • 0037304228 scopus 로고    scopus 로고
    • Biomechanics and muscle coordination of human walking: part II: lessons from dynamical simulations and clinical implications
    • Zajac FE, Neptune RR, Kautz SA, (2003) Biomechanics and muscle coordination of human walking: part II: lessons from dynamical simulations and clinical implications. Gait Posture 17: 1-17.
    • (2003) Gait Posture , vol.17 , pp. 1-17
    • Zajac, F.E.1    Neptune, R.R.2    Kautz, S.A.3
  • 6
    • 0003715001 scopus 로고
    • Biomechanics: mechanical properties of living tissues
    • Springer
    • Y-cheng Fung, (1993) Biomechanics: mechanical properties of living tissues. Springer.
    • (1993)
    • Fung, Y.-C.1
  • 7
    • 0017784732 scopus 로고
    • Dynamic stiffness and crossbridge action in muscle
    • Mason P, (1977) Dynamic stiffness and crossbridge action in muscle. BiophysStructMech 4: 15-25.
    • (1977) BiophysStructMech , vol.4 , pp. 15-25
    • Mason, P.1
  • 8
    • 0019390452 scopus 로고
    • The relation between stiffness and filament overlap in stimulated frog muscle fibres
    • Ford LE, Huxley AF, Simmons RM, (1981) The relation between stiffness and filament overlap in stimulated frog muscle fibres. J Physiol (Lond) 311: 219-249.
    • (1981) J Physiol (Lond) , vol.311 , pp. 219-249
    • Ford, L.E.1    Huxley, A.F.2    Simmons, R.M.3
  • 9
    • 0035368774 scopus 로고    scopus 로고
    • Muscle and joint elastic properties during elbow flexion in Duchenne muscular dystrophy
    • Cornu C, Goubel F, Fardeau M, (2001) Muscle and joint elastic properties during elbow flexion in Duchenne muscular dystrophy. J Physiol (Lond) 533: 605-616.
    • (2001) J Physiol (Lond) , vol.533 , pp. 605-616
    • Cornu, C.1    Goubel, F.2    Fardeau, M.3
  • 10
    • 0023907729 scopus 로고
    • Human ankle joint stiffness over the full range of muscle activation levels
    • Weiss PL, Hunter IW, Kearney RE, (1988) Human ankle joint stiffness over the full range of muscle activation levels. J Biomech 21: 539-544.
    • (1988) J Biomech , vol.21 , pp. 539-544
    • Weiss, P.L.1    Hunter, I.W.2    Kearney, R.E.3
  • 11
    • 2442466831 scopus 로고    scopus 로고
    • Supersonic shear imaging: a new technique for soft tissue elasticity mapping
    • Bercoff J, Tanter M, Fink M, (2004) Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans UltrasonFerroelectr Freq Control 51: 396-409.
    • (2004) IEEE Trans UltrasonFerroelectr Freq Control , vol.51 , pp. 396-409
    • Bercoff, J.1    Tanter, M.2    Fink, M.3
  • 12
    • 77956018769 scopus 로고    scopus 로고
    • Real-time visualization of muscle stiffness distribution with ultrasound shear wave imaging during muscle contraction
    • Shinohara M, Sabra K, Gennisson J-L, Fink M, Tanter M, (2010) Real-time visualization of muscle stiffness distribution with ultrasound shear wave imaging during muscle contraction. Muscle Nerve 42: 438-441.
    • (2010) Muscle Nerve , vol.42 , pp. 438-441
    • Shinohara, M.1    Sabra, K.2    Gennisson, J.-L.3    Fink, M.4    Tanter, M.5
  • 13
    • 77951958929 scopus 로고    scopus 로고
    • Muscle shear elastic modulus measured using supersonic shear imaging is highly related to muscle activity level
    • Nordez A, Hug F, (2010) Muscle shear elastic modulus measured using supersonic shear imaging is highly related to muscle activity level. J ApplPhysiol 108: 1389-1394.
    • (2010) J ApplPhysiol , vol.108 , pp. 1389-1394
    • Nordez, A.1    Hug, F.2
  • 14
    • 0003914248 scopus 로고
    • Biomechanics of the hand: a basic research study
    • World Scientific
    • Chao EY, (1989) Biomechanics of the hand: a basic research study. World Scientific.
    • (1989)
    • Chao, E.Y.1
  • 15
    • 79952201202 scopus 로고    scopus 로고
    • Hypothenar eminence
    • Lebreton E, (2010) Hypothenar eminence. Chir Main 29: 213-223.
    • (2010) Chir Main , vol.29 , pp. 213-223
    • Lebreton, E.1
  • 16
    • 77952308364 scopus 로고    scopus 로고
    • Viscoelastic and anisotropic mechanical properties of in vivo muscle tissue assessed by supersonic shear imaging
    • Gennisson J-L, Deffieux T, Macé E, Montaldo G, Fink M, et al. (2010) Viscoelastic and anisotropic mechanical properties of in vivo muscle tissue assessed by supersonic shear imaging. Ultrasound Med Biol 36: 789-801.17.
    • (2010) Ultrasound Med Biol , vol.36
    • Gennisson, J.-L.1    Deffieux, T.2    Macé, E.3    Montaldo, G.4    Fink, M.5
  • 17
    • 0038165821 scopus 로고    scopus 로고
    • Transient elastography in anisotropic medium: application to the measurement of slow and fast shear wave speeds in muscles
    • Gennisson J-L, Catheline S, Chaffaï S, Fink M, (2003) Transient elastography in anisotropic medium: application to the measurement of slow and fast shear wave speeds in muscles. J Acoust Soc Am 114: 536-541.
    • (2003) J Acoust Soc Am , vol.114 , pp. 536-541
    • Gennisson, J.-L.1    Catheline, S.2    Chaffaï, S.3    Fink, M.4
  • 18
    • 11144347615 scopus 로고    scopus 로고
    • Measuring of viscoelastic properties of homogeneous soft solid using transient elastography: an inverse problem approach
    • Catheline S, Gennisson JL, Delon G, Fink M, Sinkus R, et al. (2004) Measuring of viscoelastic properties of homogeneous soft solid using transient elastography: an inverse problem approach. J Acoust Soc Am 116: 3734-3741.
    • (2004) J Acoust Soc Am , vol.116 , pp. 3734-3741
    • Catheline, S.1    Gennisson, J.L.2    Delon, G.3    Fink, M.4    Sinkus, R.5
  • 19
    • 52649105387 scopus 로고    scopus 로고
    • Characterization of muscle belly elastic properties during passive stretching using transient elastography
    • Nordez A, Gennisson JL, Casari P, Catheline S, Cornu C, (2008) Characterization of muscle belly elastic properties during passive stretching using transient elastography. J Biomech 41: 2305-2311.
    • (2008) J Biomech , vol.41 , pp. 2305-2311
    • Nordez, A.1    Gennisson, J.L.2    Casari, P.3    Catheline, S.4    Cornu, C.5
  • 20
    • 61449131569 scopus 로고    scopus 로고
    • Shear wave spectroscopy for in vivo quantification of human soft tissues visco-elasticity
    • Deffieux T, Montaldo G, Tanter M, Fink M, (2009) Shear wave spectroscopy for in vivo quantification of human soft tissues visco-elasticity. IEEE Trans Med Imaging 28: 313-322.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 313-322
    • Deffieux, T.1    Montaldo, G.2    Tanter, M.3    Fink, M.4
  • 21
  • 22
    • 0016699080 scopus 로고
    • The relation between the surface electromyogram and muscular force
    • Milner-Brown HS, Stein RB, (1975) The relation between the surface electromyogram and muscular force. J Physiol (Lond) 246: 549-569.
    • (1975) J Physiol (Lond) , vol.246 , pp. 549-569
    • Milner-Brown, H.S.1    Stein, R.B.2
  • 23
    • 0020563311 scopus 로고
    • Myoelectric signal versus force relationship in different human muscles
    • Lawrence JH, De Luca CJ, (1983) Myoelectric signal versus force relationship in different human muscles. J ApplPhysiol 54: 1653-1659.
    • (1983) J ApplPhysiol , vol.54 , pp. 1653-1659
    • Lawrence, J.H.1    de Luca, C.J.2
  • 24
    • 34547285018 scopus 로고    scopus 로고
    • Relation between isometric muscle force and surface EMG in intrinsic hand muscles as function of the arm geometry
    • Del Santo F, Gelli F, Ginanneschi F, Popa T, Rossi A, (2007) Relation between isometric muscle force and surface EMG in intrinsic hand muscles as function of the arm geometry. Brain Res 1163: 79-85.
    • (2007) Brain Res , vol.1163 , pp. 79-85
    • Del Santo, F.1    Gelli, F.2    Ginanneschi, F.3    Popa, T.4    Rossi, A.5
  • 26
    • 0036845093 scopus 로고    scopus 로고
    • Evaluation of healthy and diseased muscle with magnetic resonance elastography
    • Basford JR, Jenkyn TR, An K-N, Ehman RL, Heers G, et al. (2002) Evaluation of healthy and diseased muscle with magnetic resonance elastography. Arch Phys Med Rehabil 83: 1530-1536.
    • (2002) Arch Phys Med Rehabil , vol.83 , pp. 1530-1536
    • Basford, J.R.1    Jenkyn, T.R.2    An, K.-N.3    Ehman, R.L.4    Heers, G.5
  • 27
    • 77952951306 scopus 로고    scopus 로고
    • Electromyogram and force fluctuation during different linearly varying isometric motor tasks
    • Orizio C, Baruzzi E, Gaffurini P, Diemont B, Gobbo M, (2010) Electromyogram and force fluctuation during different linearly varying isometric motor tasks. J ElectromyogrKinesiol 20: 732-741.
    • (2010) J ElectromyogrKinesiol , vol.20 , pp. 732-741
    • Orizio, C.1    Baruzzi, E.2    Gaffurini, P.3    Diemont, B.4    Gobbo, M.5
  • 28
    • 77951973533 scopus 로고    scopus 로고
    • Architectural properties of the first dorsal interosseous muscle
    • Infantolino BW, Challis JH, (2010) Architectural properties of the first dorsal interosseous muscle. J Anat 216: 463-469.
    • (2010) J Anat , vol.216 , pp. 463-469
    • Infantolino, B.W.1    Challis, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.