Volumn 26, Issue 2, 2012, Pages 141-153

Reducing and correcting for contamination of ecosystem water stable isotopes measured by isotope ratio infrared spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION SPECTROSCOPY; CONTAMINATION; DISTILLATION; EXTRACTION; INFRARED SPECTROSCOPY; ISOTOPES; LAKES; MASS SPECTROMETRY; SOIL MOISTURE; SOIL POLLUTION;

EID: 83755163183     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.5317     Document Type: Article
Times cited : (25)

References (27)
  • 4
    • 77749338160 scopus 로고    scopus 로고
    • 18O measurements using off-axis integrated cavity output spectroscopy
    • 18O measurements using off-axis integrated cavity output spectroscopy. Atmos. Meas. Technol. 2010, 3, 67.
    • (2010) Atmos. Meas. Technol. , vol.3 , pp. 67
    • Sturm, P.1    Knohl, A.2
  • 5
    • 20544431502 scopus 로고    scopus 로고
    • In situ measurement of the water vapor O-18/O-16 isotope ratio for atmospheric and ecological applications
    • X. H. Lee, S. Sargent, R. Smith, B. Tanner,. In situ measurement of the water vapor O-18/O-16 isotope ratio for atmospheric and ecological applications. J. Atmos. Oceanic Technol. 2005, 22, 555.
    • (2005) J. Atmos. Oceanic Technol. , vol.22 , pp. 555
    • Lee, X.H.1    Sargent, S.2    Smith, R.3    Tanner, B.4
  • 6
    • 67749127453 scopus 로고    scopus 로고
    • Demonstration of high-precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technology
    • P. Gupta, D. Noone, J. Galewsky, C. Sweeney, B. H. Vaughn,. Demonstration of high-precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technology. Rapid Commun. Mass Spectrom. 2009, 23, 2534.
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , pp. 2534
    • Gupta, P.1    Noone, D.2    Galewsky, J.3    Sweeney, C.4    Vaughn, B.H.5
  • 9
    • 79751507984 scopus 로고    scopus 로고
    • Hydrogen isotope correction for laser instrument measurement bias at low water vapor concentration using conventional isotope analyses: Application to measurements from Mauna Loa Observatory, Hawaii
    • L. R. Johnson, Z. D. Sharp, J. Galewsky, M. Strong, A. D. Van Pelt, F. Dong, D. Noone,. Hydrogen isotope correction for laser instrument measurement bias at low water vapor concentration using conventional isotope analyses: application to measurements from Mauna Loa Observatory, Hawaii. Rapid Commun. Mass Spectrom. 2011, 25, 608.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 608
    • Johnson, L.R.1    Sharp, Z.D.2    Galewsky, J.3    Strong, M.4    Van Pelt, A.D.5    Dong, F.6    Noone, D.7
  • 10
    • 77954493603 scopus 로고    scopus 로고
    • Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters
    • A. G. West, G. R. Goldsmith, P. D. Brooks, T. E. Dawson,. Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters. Rapid Commun. Mass Spectrom. 2010, 24, 1948.
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 1948
    • West, A.G.1    Goldsmith, G.R.2    Brooks, P.D.3    Dawson, T.E.4
  • 11
    • 78649437481 scopus 로고    scopus 로고
    • Analysis of the hydrogen and oxygen stable isotope ratios of beverage waters without prior water extraction using isotope ratio infrared spectroscopy
    • L. A. Chesson, G. J. Bowen, J. R. Ehleringer,. Analysis of the hydrogen and oxygen stable isotope ratios of beverage waters without prior water extraction using isotope ratio infrared spectroscopy. Rapid Commun. Mass Spectrom. 2010, 24, 3205.
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 3205
    • Chesson, L.A.1    Bowen, G.J.2    Ehleringer, J.R.3
  • 13
    • 79960347976 scopus 로고    scopus 로고
    • Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS)
    • A. G. West, G. R. Goldsmith, I. Matimati, T. E. Dawson,. Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS). Rapid Commun. Mass Spectrom. 2011, 25, 2268.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 2268
    • West, A.G.1    Goldsmith, G.R.2    Matimati, I.3    Dawson, T.E.4
  • 14
    • 77955411519 scopus 로고    scopus 로고
    • Comments on "discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters"
    • W. A. Brand,. Comments on "Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters". Rapid Commun. Mass Spectrom. 2010, 24, 2687.
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 2687
    • Brand, W.A.1
  • 15
    • 80053222053 scopus 로고    scopus 로고
    • Detailed assessment of isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters
    • L. Zhao, H. Xiao, J. Zhou, L. Wang, G. Cheng, M. Zhou, L. Yin, M. F. McCabe,. Detailed assessment of isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters. Rapid Commun. Mass Spectrom. 2011, 25, 3071.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 3071
    • Zhao, L.1    Xiao, H.2    Zhou, J.3    Wang, L.4    Cheng, G.5    Zhou, M.6    Yin, L.7    McCabe, M.F.8
  • 16
    • 50649083905 scopus 로고    scopus 로고
    • A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water vapor
    • E. R. Crosson,. A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water vapor. Appl. Phys. B-Laser Opt. 2008, 92, 403.
    • (2008) Appl. Phys. B-Laser Opt. , vol.92 , pp. 403
    • Crosson, E.R.1
  • 17
    • 0029413066 scopus 로고
    • Isotope effects accompanying vacuum extraction of soil water for stable isotope analyses
    • L. Araguás-Araguás, K. Rozanski, R. Gonfiantini, D. Louvat,. Isotope effects accompanying vacuum extraction of soil water for stable isotope analyses. J. Hydrol. 1995, 168, 159.
    • (1995) J. Hydrol. , vol.168 , pp. 159
    • Araguás-Araguás, L.1    Rozanski, K.2    Gonfiantini, R.3    Louvat, D.4
  • 18
    • 33645851971 scopus 로고    scopus 로고
    • Water extraction times for plant and soil materials used in stable isotope analysis
    • A. G. West, S. J. Patrickson, J. R. Ehleringer,. Water extraction times for plant and soil materials used in stable isotope analysis. Rapid Commun. Mass Spectrom. 2006, 20, 1317.
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 1317
    • West, A.G.1    Patrickson, S.J.2    Ehleringer, J.R.3
  • 19
    • 53049094945 scopus 로고    scopus 로고
    • A direct and rapid leaf water extraction method for isotopic analysis
    • L. I. Peters, D. Yakir,. A direct and rapid leaf water extraction method for isotopic analysis. Rapid Commun. Mass Spectrom. 2008, 22, 2929.
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , pp. 2929
    • Peters, L.I.1    Yakir, D.2
  • 22
    • 0029197352 scopus 로고
    • Temporal and spatial variations in the oxygen-18 content of leaf water in different plant species
    • X.-F. Wang, D. Yakir,. Temporal and spatial variations in the oxygen-18 content of leaf water in different plant species. Plant Cell Environ. 1995, 18, 1377.
    • (1995) Plant Cell Environ. , vol.18 , pp. 1377
    • Wang, X.-F.1    Yakir, D.2
  • 23
    • 85153994910 scopus 로고    scopus 로고
    • Picarro, Inc. Santa Clara, CA, USA
    • G. Hsiao, Picarro, Inc., Santa Clara, CA, USA.
    • Hsiao, G.1
  • 25
    • 0011859785 scopus 로고    scopus 로고
    • Inc. La Jolla, CA, USA
    • GraphPad Software, Inc., La Jolla, CA, USA. Available
    • GraphPad Software
  • 27
    • 0028192595 scopus 로고
    • Interlaboratory comparison of methods to determine the stable isotope composition of soil water
    • G. R. Walker, P. H. Woods, G. B. Allison,. Interlaboratory comparison of methods to determine the stable isotope composition of soil water. Chem. Geol. 1994, 111, 297.
    • (1994) Chem. Geol. , vol.111 , pp. 297
    • Walker, G.R.1    Woods, P.H.2    Allison, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.