메뉴 건너뛰기




Volumn 26, Issue 1, 2012, Pages 9-18

Plating of acute humeral diaphyseal fractures through an anterior approach in multiple trauma patients

Author keywords

anterior approach; anterolateral approach; diaphysis; humeral shaft; multiple trauma; open reduction internal fixation; small fragment; supine

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; FEMALE; FOLLOW UP; FRACTURE FIXATION; FRACTURE HEALING; FRACTURE NONUNION; HUMAN; HUMERUS FRACTURE; MAJOR CLINICAL STUDY; MALE; MULTIPLE TRAUMA; OPEN REDUCTION; OPERATION DURATION; OSTEOSYNTHESIS; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; PROSTHESIS FAILURE; RANGE OF MOTION; RETROSPECTIVE STUDY; SUPINE POSITION; SURGICAL APPROACH;

EID: 83655184674     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318214ebd5     Document Type: Article
Times cited : (26)

References (40)
  • 1
    • 67649906617 scopus 로고    scopus 로고
    • Fractures of the shaft of the humerus
    • Bucholz R, Heckman JD, Court-Brown CM, eds. Philadelphia: Lippincott Williams & Wilkins
    • McKee MD. Fractures of the shaft of the humerus. In: Bucholz R, Heckman JD, Court-Brown CM, eds. Rockwood and Green's: Fractures in Adults. Philadelphia: Lippincott Williams & Wilkins; 2006:1118-1159.
    • (2006) Rockwood and green'S: Fractures in Adults , pp. 1118-1159
    • McKee, M.D.1
  • 3
    • 33750693052 scopus 로고    scopus 로고
    • Treatment of diaphyseal fractures of the humerus using a functional brace
    • DOI 10.1097/01.bot.0000249423.48074.82, PII 0000513120061000000002
    • Rutgers M, Ring D. Treatment of diaphyseal fractures of the humerus using a functional brace. J Orthop Trauma. 2006;20:597-601. (Pubitemid 44706899)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.9 , pp. 597-601
    • Rutgers, M.1    Ring, D.2
  • 4
    • 0016017170 scopus 로고
    • Fresh fractures of the shaft of the humerus - Conservative or operative treatment?
    • Ruedi T, Moshfegh A, Pfeiffer KM, et al. Fresh fractures of the shaft of the humerus - conservative or operative treatment? Reconstr Surg Traumatol. 1974;14:65-74.
    • (1974) Reconstr Surg Traumatol , vol.14 , pp. 65-74
    • Ruedi, T.1    Moshfegh, A.2    Pfeiffer, K.M.3
  • 5
    • 0021950634 scopus 로고
    • The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience
    • Bell MJ, Beauchamp CG, Kellam JK, et al. The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br. 1985;67:293-396.
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 293-396
    • Bell, M.J.1    Beauchamp, C.G.2    Kellam, J.K.3
  • 6
    • 0016161259 scopus 로고
    • Fractures of the humeral shaft associated with multiple injuries
    • Vichare NA. Fractures of the humeral shaft associated with multiple injuries. Injury. 1974;5:279-282.
    • (1974) Injury , vol.5 , pp. 279-282
    • Vichare, N.A.1
  • 7
    • 0028902015 scopus 로고
    • Being overweight and multiple fractures are indications for operative treatment of humeral shaft fractures
    • Jensen AT, Rasmussen S. Being overweight and multiple fractures are indications for operative treatment of humeral shaft fractures. Injury. 1995;26:263-264.
    • (1995) Injury , vol.26 , pp. 263-264
    • Jensen, A.T.1    Rasmussen, S.2
  • 8
    • 0026462030 scopus 로고
    • Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries
    • Dabezies EJ, Banta CJ 2nd, Murphy CP, et al. Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries. J Orthop Trauma. 1992;6:10-13.
    • (1992) J Orthop Trauma , vol.6 , pp. 10-13
    • Dabezies, E.J.1    Banta II, C.J.2    Murphy, C.P.3
  • 9
    • 2342641983 scopus 로고    scopus 로고
    • Plating of humeral shaft fractures - Has the pendulum swung back?
    • DOI 10.1016/j.injury.2003.10.021, PII S0020138303004650
    • Niall DM, O'Mahony J, McElwain JP. Plating of humeral shaft fractures - has the pendulum swung back? Injury. 2004;35:580-586. (Pubitemid 38595393)
    • (2004) Injury , vol.35 , Issue.6 , pp. 580-586
    • Niall, D.M.1    O'Mahony, J.2    McElwain, J.P.3
  • 11
    • 0036941723 scopus 로고    scopus 로고
    • Operative treatment of humeral shaft fractures the Leuven experience
    • Meekers FS, Broos PL. Operative treatment of humeral shaft fractures. The Leuven experience. Acta Orthop Belg. 2002;68:462-470. (Pubitemid 36061483)
    • (2002) Acta Orthopaedica Belgica , vol.68 , Issue.5 , pp. 462-470
    • Meekers, F.S.L.1    Broos, P.L.O.2
  • 12
    • 0034152245 scopus 로고    scopus 로고
    • Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates
    • Chapman JR, Henley MB, Agel J, et al. Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates. J Orthop Trauma. 2000;14:162-166.
    • (2000) J Orthop Trauma , vol.14 , pp. 162-166
    • Chapman, J.R.1    Henley, M.B.2    Agel, J.3
  • 13
    • 77449113724 scopus 로고    scopus 로고
    • Locked intramedullary nailing versus dynamic compression plating for humeral shaft fractures
    • Putti AB, Uppin RB, Putti BB. Locked intramedullary nailing versus dynamic compression plating for humeral shaft fractures. J Orthop Surg (Hong Kong). 2009;17:139-141.
    • (2009) J Orthop Surg (Hong Kong) , vol.17 , pp. 139-141
    • Putti, A.B.1    Uppin, R.B.2    Putti, B.B.3
  • 14
    • 77957574191 scopus 로고    scopus 로고
    • Immediate plate osteosynthesis of open fractures of the humeral shaft
    • Connolly S, McKee MD, Zdero R, et al. Immediate plate osteosynthesis of open fractures of the humeral shaft. J Trauma. 2010;69:685-690.
    • (2010) J Trauma , vol.69 , pp. 685-690
    • Connolly, S.1    McKee, M.D.2    Zdero, R.3
  • 15
    • 0004136708 scopus 로고
    • New York: Churchill Livingstone
    • Henry A. Extensile Exposure. New York: Churchill Livingstone; 1995:25-37.
    • (1995) Extensile Exposure , pp. 25-37
    • Henry, A.1
  • 16
    • 0033821667 scopus 로고    scopus 로고
    • Effect of immediate weightbearing on plated fractures of the humeral shaft
    • Tingstad EM,Wolinsky PR, Shyr Y, et al. Effect of immediate weightbearing on plated fractures of the humeral shaft. J Trauma. 2000;49:278-280.
    • (2000) J Trauma , vol.49 , pp. 278-280
    • Tingstad, E.M.1    Wolinsky, P.R.2    Shyr, Y.3
  • 17
    • 0021961024 scopus 로고
    • Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study
    • Foster RJ, Dixon GL Jr, Bach AW, et al. Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study. J Bone Joint Surg Am. 1985;67:857-864. (Pubitemid 15240308)
    • (1985) Journal of Bone and Joint Surgery - Series A , vol.67 , Issue.6 , pp. 857-864
    • Foster, R.J.1    Dixon Jr., G.L.2    Bach, A.W.3
  • 18
    • 33750812273 scopus 로고    scopus 로고
    • Extra-articular distal-third diaphyseal fractures of the humerus: A comparison of functional bracing and plate fixation
    • DOI 10.2106/JBJS.F.00334
    • Jawa A, McCarty P, Doornberg J, et al. Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am. 2006;88:2343-2347. (Pubitemid 44713819)
    • (2006) Journal of Bone and Joint Surgery - Series A , vol.88 , Issue.11 , pp. 2343-2347
    • Jawa, A.1    McCarty, P.2    Doornberg, J.3    Harris, M.4    Ring, D.5
  • 20
    • 33750724124 scopus 로고    scopus 로고
    • Outcome after closed functional treatment of humeral shaft fractures
    • DOI 10.1097/01.bot.0000246466.01287.04, PII 0000513120061000000001
    • Ekholm R, Tidermark J, Törnkvist H, et al. Outcome after closed functional treatment of humeral shaft fractures. J Orthop Trauma. 2006;20:591-596. (Pubitemid 44706898)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.9 , pp. 591-596
    • Ekholm, R.1    Tidermark, J.2    Tornkvist, H.3    Adami, J.4    Ponzer, S.5
  • 21
    • 34249061825 scopus 로고    scopus 로고
    • Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study
    • DOI 10.1007/s00264-006-0200-1
    • Changulani M, Jain UK, Keswani T. Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop. 2007;31:391-395. (Pubitemid 46800766)
    • (2007) International Orthopaedics , vol.31 , Issue.3 , pp. 391-395
    • Changulani, M.1    Jain, U.K.2    Keswani, T.3
  • 22
    • 33750127403 scopus 로고    scopus 로고
    • Posteromedial approach to the distal humerus for fracture fixation
    • Laporte C, Thiongo M, Jegou D. Posteromedial approach to the distal humerus for fracture fixation. Acta Orthop Belg. 2006;72:395-399. (Pubitemid 44726562)
    • (2006) Acta Orthopaedica Belgica , vol.72 , Issue.4 , pp. 395-399
    • Laporte, C.1    Thiongo, M.2    Jegou, D.3
  • 23
    • 0033126760 scopus 로고    scopus 로고
    • Complications of intramedullary nailing for fractures of the humeral shaft: A review
    • Farragos AF, Schemitsch EH, McKee MD. Complications of intramedullary nailing for fractures of the humeral shaft: a review. J Orthop Trauma. 1999;13:258-267.
    • (1999) J Orthop Trauma , vol.13 , pp. 258-267
    • Farragos, A.F.1    Schemitsch, E.H.2    McKee, M.D.3
  • 24
    • 0037336673 scopus 로고    scopus 로고
    • Iatrogenic nerve injury with the Russell-Taylor humeral nail
    • DOI 10.1016/S0020-1383(01)00176-0, PII S0020138301001760
    • Blyth MJ, Macleod CM, Asante DK, et al. Iatrogenic nerve injury with the Russell-Taylor humeral nail. Injury. 2003;34:227-228. (Pubitemid 36288398)
    • (2003) Injury , vol.34 , Issue.3 , pp. 227-228
    • Blyth, M.J.G.1    Macleod, C.M.B.2    Asante, D.K.3    Kinninmonth, A.W.G.4
  • 25
    • 0031912864 scopus 로고    scopus 로고
    • Operative management of diaphyseal fractures of the humerus. Plate versus nail
    • Modabber MR, Jupiter JB. Operative management of diaphyseal fractures of the humerus. Plate versus nail. Clin Orthop Relat Res. 1998;347:93-104.
    • (1998) Clin Orthop Relat Res , vol.347 , pp. 93-104
    • Modabber, M.R.1    Jupiter, J.B.2
  • 26
    • 68149179045 scopus 로고    scopus 로고
    • Iatrogenic radial nerve palsy after operative management of humeral shaft fractures
    • Wang JP, Shen WJ, Chen WM, et al. Iatrogenic radial nerve palsy after operative management of humeral shaft fractures. J Trauma. 2009;66:800-803.
    • (2009) J Trauma , vol.66 , pp. 800-803
    • Wang, J.P.1    Shen, W.J.2    Chen, W.M.3
  • 28
    • 74249114212 scopus 로고    scopus 로고
    • Biomechanical testing of unstable humeral shaft fracture plating
    • Catanzarite J, Alan R, Baig R, et al. Biomechanical testing of unstable humeral shaft fracture plating. J Surg Orthop Adv. 2009;18:175-181.
    • (2009) J Surg Orthop Adv , vol.18 , pp. 175-181
    • Catanzarite, J.1    Alan, R.2    Baig, R.3
  • 29
    • 59049091563 scopus 로고    scopus 로고
    • Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone
    • O'Toole RV, Andersen RC, Vesnovsky O, et al. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone. J Orthop Trauma. 2008;22:709-715.
    • (2008) J Orthop Trauma , vol.22 , pp. 709-715
    • O'Toole, R.V.1    Andersen, R.C.2    Vesnovsky, O.3
  • 33
    • 42049102809 scopus 로고    scopus 로고
    • Comparison of three different treatment modalities in the management of humeral shaft nonunions (plates, unilateral, and circular external fixators)
    • DOI 10.1097/BOT.0b013e31816c7b89, PII 0000513120080400000008
    • Atalar AC, Kocaoglu M, Demirhan M, et al. Comparison of three different treatment modalities in the management of humeral shaft nonunions (plates, unilateral, and circular external fixators). J Orthop Trauma. 2008;22:248-257. (Pubitemid 351521602)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.4 , pp. 248-257
    • Atalar, A.C.1    Kocaoglu, M.2    Demirhan, M.3    Bilsel, K.4    Eralp, L.5
  • 34
    • 0033635969 scopus 로고    scopus 로고
    • Functional outcome following surgical treatment of intra-articular distal humeral fractures through a posterior approach
    • McKee MD, Wilson TL, Winston L, et al. Functional outcome following surgical treatment of intra-articular distal humeral fractures through a posterior approach. J Bone Joint Surg Am. 2000;82:1701-1707.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1701-1707
    • McKee, M.D.1    Wilson, T.L.2    Winston, L.3
  • 35
    • 43249104400 scopus 로고    scopus 로고
    • Percutaneous humeral plating of fractures of the proximal humerus: Results of a prospective multicenter clinical trial
    • DOI 10.1097/BOT.0b013e3181694f7d, PII 0000513120080300000001
    • Laflamme GY, Rouleau DM, Berry GK, et al. Percutaneous humeral plating of fractures of the proximal humerus: results of a prospective multicenter clinical trial. J Orthop Trauma. 2008;22:153-158. (Pubitemid 351654231)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.3 , pp. 153-158
    • Laflamme, G.Y.1    Rouleau, D.M.2    Berry, G.K.3    Beaumont, P.H.4    Reindl, R.5    Harvey, E.J.6
  • 37
    • 67649869541 scopus 로고    scopus 로고
    • Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study
    • Sudkamp N, Bayer J, Hepp P, et al. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am. 2009;91:1320-1328.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 1320-1328
    • Sudkamp, N.1    Bayer, J.2    Hepp, P.3
  • 38
    • 14744300697 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture: Is it possible? A cadaveric study and preliminary report
    • DOI 10.1016/j.injury.2004.05.036
    • Apivatthakakul T, Arpornchayanon O, Bavornratanavech S. Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury. 2005;36:530-538. (Pubitemid 40332338)
    • (2005) Injury , vol.36 , Issue.4 , pp. 530-538
    • Apivatthakakul, T.1    Arpornchayanon, O.2    Bavornratanavech, S.3
  • 40
    • 35148886200 scopus 로고    scopus 로고
    • Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
    • DOI 10.1097/BOT.0b013e31815928c2, PII 0000513120071000000006
    • Zhiquan A, Bingfang Z, Yeming W, et al. Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma. 2007;21:628-633. (Pubitemid 47549097)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.9 , pp. 628-633
    • Zhiquan, A.1    Bingfang, Z.2    Yeming, W.3    Chi, Z.4    Peiyan, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.