메뉴 건너뛰기




Volumn 53, Issue 6, 2011, Pages 86-88

Displacement ventilation in hospital environments

Author keywords

[No Author keywords available]

Indexed keywords

DISPLACEMENT VENTILATION; DUAL ROLE; FLOOR LEVEL; HOSPITAL ENVIRONMENT; INFECTED PATIENTS; LOW VELOCITIES; WAITING AREAS;

EID: 83455181957     PISSN: 00012491     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (24)

References (14)
  • 2
    • 0027277152 scopus 로고
    • Effects of thermal radiation on airflow with displacement ventilation: an experimental investigation
    • DOI 10.1016/0378-7788(93)90011-I
    • Li, Y., M. Sandberg, L. Fuchs. 1993. "Effects of thermal radiation on airflow with displacement ventilation: an experimental investigation. " Energy and Buildings 19 (4):263-274. (Pubitemid 23711432)
    • (1993) Energy and Buildings , vol.19 , Issue.4 , pp. 263-274
    • Li Yuguo1    Sandberg Mats2    Fuchs Laszlo3
  • 3
    • 0000582130 scopus 로고    scopus 로고
    • Personal exposure in displacement ventilated rooms
    • Brohus, H., P. V. Nielsen. 1996. "Personal exposure in displacement ventilated rooms." Indoor Air 6 (3):157-167. (Pubitemid 126732125)
    • (1996) Indoor Air , vol.6 , Issue.3 , pp. 157-167
    • Brohus, H.1
  • 5
    • 35948958566 scopus 로고    scopus 로고
    • Study of expiratory droplet dispersion and transport using a new Eulerian modeling approach
    • DOI 10.1016/j.atmosenv.2007.05.045, PII S1352231007005031
    • Lai, A. C. K., Y. C. Cheng. 2007. "Study of expiratory droplet dispersion and transport using a new Eulerian modeling approach." Atmospheric Environment 41 (35):7473-7484. (Pubitemid 350064571)
    • (2007) Atmospheric Environment , vol.41 , Issue.35 , pp. 7473-7484
    • Lai, A.C.K.1    Cheng, Y.C.2
  • 6
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjørn, E., P. V. Nielsen. 2002. "Dispersal of exhaled air and personal exposure in displacement ventilated rooms." Indoor Air 12:147-64. (Pubitemid 135746000)
    • (2002) Indoor Air , vol.12 , Issue.3 , pp. 147-164
    • Bjorn, E.1    Nielsen, P.V.2
  • 7
    • 33644697163 scopus 로고    scopus 로고
    • Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems
    • DOI 10.1111/j.1600-0668.2005.00407.x
    • Qian, H., et al. 2006. "Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems." Indoor Air 16 (2):111-128. (Pubitemid 43330377)
    • (2006) Indoor Air , vol.16 , Issue.2 , pp. 111-128
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hyldgaard, C.E.4    Wong, T.W.5    Chwang, A.T.Y.6
  • 8
    • 84855189472 scopus 로고    scopus 로고
    • Air quality in the near zone of humans with different ventilation strategies
    • th AIVC Conference.
    • (2008) th AIVC Conference
    • Mundt, E.1
  • 9
    • 80052443967 scopus 로고    scopus 로고
    • Spatial distribution of human respiratory droplet residuals and exposure risk for the co-occupant under different ventilation methods
    • Li, X., J. Niu, N. Gao. 2011. "Spatial distribution of human respiratory droplet residuals and exposure risk for the co-occupant under different ventilation methods." To be published in HVAC&R Research.
    • (2011) HVAC&R Research
    • Li, X.1    Niu, J.2    Gao, N.3
  • 10
    • 1542599487 scopus 로고
    • Comparison between three air distribution systems for operating rooms
    • Hillerbrant, B., B. Ljungqvist. 1990. "Comparison between three air distribution systems for operating rooms." Swiss Contamination Control, No 4 a: 336-339.
    • (1990) Swiss Contamination Control , Issue.4 A , pp. 336-339
    • Hillerbrant, B.1    Ljungqvist, B.2
  • 11
    • 77949358308 scopus 로고    scopus 로고
    • Experimental study on displacement and mixing ventilation systems for a patient ward
    • Yin, Y, et al. 2009. "Experimental study on displacement and mixing ventilation systems for a patient ward." HVAC&R Research 15 (6):1175-1191.
    • (2009) HVAC&R Research , vol.15 , Issue.6 , pp. 1175-1191
    • Yin, Y.1
  • 12
    • 77952582124 scopus 로고    scopus 로고
    • Risk of cross-infection in a hospital ward with downward ventilation
    • Nielsen, P. V., et al. 2010. "Risk of cross-infection in a hospital ward with downward ventilation. " Building and Environment 45 (9):2008-2014.
    • (2010) Building and Environment , vol.45 , Issue.9 , pp. 2008-2014
    • Nielsen, P.V.1
  • 13
    • 77955138400 scopus 로고    scopus 로고
    • Removal of exhaled particles by ventilation and deposition in a multibed airborne infection isolation room
    • Qian, H., Y. Li. 2010. "Removal of exhaled particles by ventilation and deposition in a multibed airborne infection isolation room." Indoor Air 20 (4):284-297.
    • (2010) Indoor Air , vol.20 , Issue.4 , pp. 284-297
    • Qian, H.1    Li, Y.2
  • 14
    • 77956601033 scopus 로고    scopus 로고
    • Natural ventilation for infection control in health-care settings. WHO guidelines
    • Atkinson J, et al. 2009. "Natural Ventilation for Infection Control in Health-Care Settings. WHO Guidelines" World Health Organization.
    • (2009) World Health Organization
    • Atkinson, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.