-
1
-
-
0003956241
-
-
Association of anaesthetists of Great Britain and Ireland. London: Association of Anaesthetists; Available at: Accessed 12 Dec 2008
-
Association of anaesthetists of Great Britain and Ireland. Recommendations for standards of monitoring during anaesthesia and recovery. London: Association of Anaesthetists; 2007. Available at: http://www.aagbi.org Accessed 12 Dec 2008.
-
(2007)
Recommendations for Standards of Monitoring during Anaesthesia and Recovery
-
-
-
2
-
-
0025348830
-
Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients
-
Jubran A, Tobin MJ. Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. Chest 1990; 97: 1420-1425. (Pubitemid 20185691)
-
(1990)
Chest
, vol.97
, Issue.6
, pp. 1420-1425
-
-
Jubran, A.1
Tobin, M.J.2
-
3
-
-
53549099668
-
British Thoracic Society guideline for emergency oxygen use in adults
-
O'Driscoll BR, Howard LS, Davison AG. British Thoracic Society guideline for emergency oxygen use in adults. Thorax 2008; 63(Suppl 6):vi1-68.
-
(2008)
Thorax
, vol.63
, Issue.SUPPL. 6
-
-
O'Driscoll, B.R.1
Howard, L.S.2
Davison, A.G.3
-
4
-
-
0034754475
-
Accuracy of pulse oximetry in the intensive care unit
-
DOI 10.1007/s001340101064
-
Van de Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med 2001; 27: 1606-1613. (Pubitemid 33027957)
-
(2001)
Intensive Care Medicine
, vol.27
, Issue.10
, pp. 1606-1613
-
-
Louw, A.1
Cracco, C.2
Cerf, C.3
Harf, A.4
Duvaldestin, P.5
Lemaire, F.6
Brochard, L.7
-
5
-
-
0031800328
-
Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation
-
DOI 10.1097/00003246-199806000-00040
-
Carter BG, Carlin JB, Tibballs J, Mead H, Hochmann M, Osborne A. Accuracy of two pulse oximeters at low arterial haemoglobin-oxygen saturation. Crit Care Med 1998; 26: 1128-1133. (Pubitemid 28272868)
-
(1998)
Critical Care Medicine
, vol.26
, Issue.6
, pp. 1128-1133
-
-
Carter, B.G.1
Carlin, J.B.2
Tibballs, J.3
Mead, H.4
Hochmann, M.5
Osborne, A.6
-
6
-
-
0027533371
-
Accuracy of pulse oximetry in children with cyanotic congenital heart disease
-
DOI 10.1016/1053-0770(93)90120-A
-
Schmitt HJ, Schuetz WH, Proeschel PA, Jaklin C. Accuracy of pulse oximetry in children with cyanotic congenital heart disease. J Cardiothorac Vasc Anesth 1993; 7: 61-65. (Pubitemid 23065638)
-
(1993)
Journal of Cardiothoracic and Vascular Anesthesia
, vol.7
, Issue.1
, pp. 61-65
-
-
Schmitt, H.J.1
Schuetz, W.H.2
Proeschel, P.A.3
Jaklin, C.4
-
7
-
-
0028286818
-
Pulse oximetry. Gold standard or false sense of security?
-
Grace RF. Pulse oximetry. Gold standard or false sense of security?. Med J Aust 1994; 160: 638-644.
-
(1994)
Med J Aust
, vol.160
, pp. 638-644
-
-
Grace, R.F.1
-
8
-
-
0024562215
-
Pulse oximetry
-
Kelleher JF. Pulse oximetry. J Clin Monit 1989; 5: 36-37.
-
(1989)
J Clin Monit
, vol.5
, pp. 36-37
-
-
Kelleher, J.F.1
-
9
-
-
1942468897
-
Comparative testing of pulse oximeter probes
-
Van Oostrom JH, Melker RJ. Comparative testing of pulse oximeter probes. Anesth Analg 2004; 98: 1354-1358. (Pubitemid 38525592)
-
(2004)
Anesthesia and Analgesia
, vol.98
, Issue.5
, pp. 1354-1358
-
-
Van Oostrom, J.H.1
Melker, R.J.2
-
10
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307-310. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
11
-
-
0022796639
-
History of blood gas analysis. VI. Oximetry
-
Severinghaus JW, Astrup PB. History of blood gas analysis. VI. Oximetry. J Clin Monit 1986; 2: 270-288.
-
(1986)
J Clin Monit
, vol.2
, pp. 270-288
-
-
Severinghaus, J.W.1
Astrup, P.B.2
-
12
-
-
0020956492
-
Evaluation of pulse oximetry
-
Yelderman M, New W Jr. Evaluation of pulse oximetry. Anesthesiology 1983; 59: 349-352. (Pubitemid 13012527)
-
(1983)
Anesthesiology
, vol.59
, Issue.4
, pp. 349-352
-
-
Yelderman, M.1
New Jr., W.2
-
13
-
-
0024414277
-
The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition
-
Kelleher JF, Ruff RH. The penumbra effect: vasomotiondependent pulse oximeter artefact due to probe malposition. Anesthesiology 1989; 71: 787-791. (Pubitemid 19275106)
-
(1989)
Anesthesiology
, vol.71
, Issue.5
, pp. 787-791
-
-
Kelleher, J.F.1
Ruff, R.H.2
-
14
-
-
0023442367
-
Falsely normal saturation reading with the pulse oximeter
-
Costarino AT, Davis DA, Keon TP. Falsely normal saturation reading with the pulse oximeter. Anesthesiology 1987; 67: 830-831.
-
(1987)
Anesthesiology
, vol.67
, pp. 830-831
-
-
Costarino, A.T.1
Davis, D.A.2
Keon, T.P.3
-
17
-
-
0024786795
-
The effect of fingerprinting ink on pulse oximetry
-
DOI 10.1213/00000539-198908000-00031
-
Battito MF. The effect of fingerprinting ink on pulse oximetry. Anesth Analg 1989; 69: 265. (Pubitemid 20045069)
-
(1989)
Anesthesia and Analgesia
, vol.69
, Issue.2
, pp. 265
-
-
Battito, M.F.1
-
18
-
-
0032932450
-
Pulse oximetry: Principles and limitations
-
DOI 10.1016/S0735-6757(99)90019-0
-
Sinex JE. Pulse oximetry: principles and Limitations. Am J Emerg Med 1999; 17: 59-66. (Pubitemid 29045394)
-
(1999)
American Journal of Emergency Medicine
, vol.17
, Issue.1
, pp. 59-66
-
-
Sinex, J.E.1
|