Volumn 25, Issue 3, 2011, Pages 163-170

Evaluation of a pulse oximeter sensor tester

Author keywords

Equipment; Measurement techniques; Pulse oximetry

Indexed keywords

ENGINEERING DEPARTMENT; FINGER PROBES; MEASUREMENT TECHNIQUES; MICRO-SPECTROMETER; OPTICAL AND ELECTRICAL PROPERTIES; OXYGEN SATURATION; PULSE OXIMETER SENSORS; PULSE OXIMETERS; PULSE OXIMETRY; RESPONSE RATE; TESTING PROCEDURE;

EID: 83155175415     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-011-9283-3     Document Type: Article
Times cited : (7)

References (21)
  • 1
    • 0003956241 scopus 로고    scopus 로고
    • Association of anaesthetists of Great Britain and Ireland. London: Association of Anaesthetists; Available at: Accessed 12 Dec 2008
    • Association of anaesthetists of Great Britain and Ireland. Recommendations for standards of monitoring during anaesthesia and recovery. London: Association of Anaesthetists; 2007. Available at: http://www.aagbi.org Accessed 12 Dec 2008.
    • (2007) Recommendations for Standards of Monitoring during Anaesthesia and Recovery
  • 2
    • 0025348830 scopus 로고
    • Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients
    • Jubran A, Tobin MJ. Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. Chest 1990; 97: 1420-1425. (Pubitemid 20185691)
    • (1990) Chest , vol.97 , Issue.6 , pp. 1420-1425
    • Jubran, A.1    Tobin, M.J.2
  • 3
    • 53549099668 scopus 로고    scopus 로고
    • British Thoracic Society guideline for emergency oxygen use in adults
    • O'Driscoll BR, Howard LS, Davison AG. British Thoracic Society guideline for emergency oxygen use in adults. Thorax 2008; 63(Suppl 6):vi1-68.
    • (2008) Thorax , vol.63 , Issue.SUPPL. 6
    • O'Driscoll, B.R.1    Howard, L.S.2    Davison, A.G.3
  • 5
    • 0031800328 scopus 로고    scopus 로고
    • Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation
    • DOI 10.1097/00003246-199806000-00040
    • Carter BG, Carlin JB, Tibballs J, Mead H, Hochmann M, Osborne A. Accuracy of two pulse oximeters at low arterial haemoglobin-oxygen saturation. Crit Care Med 1998; 26: 1128-1133. (Pubitemid 28272868)
    • (1998) Critical Care Medicine , vol.26 , Issue.6 , pp. 1128-1133
    • Carter, B.G.1    Carlin, J.B.2    Tibballs, J.3    Mead, H.4    Hochmann, M.5    Osborne, A.6
  • 7
    • 0028286818 scopus 로고
    • Pulse oximetry. Gold standard or false sense of security?
    • Grace RF. Pulse oximetry. Gold standard or false sense of security?. Med J Aust 1994; 160: 638-644.
    • (1994) Med J Aust , vol.160 , pp. 638-644
    • Grace, R.F.1
  • 8
    • 0024562215 scopus 로고
    • Pulse oximetry
    • Kelleher JF. Pulse oximetry. J Clin Monit 1989; 5: 36-37.
    • (1989) J Clin Monit , vol.5 , pp. 36-37
    • Kelleher, J.F.1
  • 9
    • 1942468897 scopus 로고    scopus 로고
    • Comparative testing of pulse oximeter probes
    • Van Oostrom JH, Melker RJ. Comparative testing of pulse oximeter probes. Anesth Analg 2004; 98: 1354-1358. (Pubitemid 38525592)
    • (2004) Anesthesia and Analgesia , vol.98 , Issue.5 , pp. 1354-1358
    • Van Oostrom, J.H.1    Melker, R.J.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0022796639 scopus 로고
    • History of blood gas analysis. VI. Oximetry
    • Severinghaus JW, Astrup PB. History of blood gas analysis. VI. Oximetry. J Clin Monit 1986; 2: 270-288.
    • (1986) J Clin Monit , vol.2 , pp. 270-288
    • Severinghaus, J.W.1    Astrup, P.B.2
  • 12
    • 0020956492 scopus 로고
    • Evaluation of pulse oximetry
    • Yelderman M, New W Jr. Evaluation of pulse oximetry. Anesthesiology 1983; 59: 349-352. (Pubitemid 13012527)
    • (1983) Anesthesiology , vol.59 , Issue.4 , pp. 349-352
    • Yelderman, M.1    New Jr., W.2
  • 13
    • 0024414277 scopus 로고
    • The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition
    • Kelleher JF, Ruff RH. The penumbra effect: vasomotiondependent pulse oximeter artefact due to probe malposition. Anesthesiology 1989; 71: 787-791. (Pubitemid 19275106)
    • (1989) Anesthesiology , vol.71 , Issue.5 , pp. 787-791
    • Kelleher, J.F.1    Ruff, R.H.2
  • 14
    • 0023442367 scopus 로고
    • Falsely normal saturation reading with the pulse oximeter
    • Costarino AT, Davis DA, Keon TP. Falsely normal saturation reading with the pulse oximeter. Anesthesiology 1987; 67: 830-831.
    • (1987) Anesthesiology , vol.67 , pp. 830-831
    • Costarino, A.T.1    Davis, D.A.2    Keon, T.P.3
  • 15
    • 0021522916 scopus 로고
    • Infrared heat lamps interfere with pulse oximeters
    • Brooks TD, Paulus DA, Winkle WE. Infrared heat lamps interfere with pulse oximeters. Anesthesiology 1984; 61: 630.
    • (1984) Anesthesiology , vol.61 , pp. 630
    • Brooks, T.D.1    Paulus, D.A.2    Winkle, W.E.3
  • 17
    • 0024786795 scopus 로고
    • The effect of fingerprinting ink on pulse oximetry
    • DOI 10.1213/00000539-198908000-00031
    • Battito MF. The effect of fingerprinting ink on pulse oximetry. Anesth Analg 1989; 69: 265. (Pubitemid 20045069)
    • (1989) Anesthesia and Analgesia , vol.69 , Issue.2 , pp. 265
    • Battito, M.F.1
  • 18
    • 0032932450 scopus 로고    scopus 로고
    • Pulse oximetry: Principles and limitations
    • DOI 10.1016/S0735-6757(99)90019-0
    • Sinex JE. Pulse oximetry: principles and Limitations. Am J Emerg Med 1999; 17: 59-66. (Pubitemid 29045394)
    • (1999) American Journal of Emergency Medicine , vol.17 , Issue.1 , pp. 59-66
    • Sinex, J.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.