-
1
-
-
34247269097
-
Perioperative blood transfusion and blood conservation in cardiac surgery: the society of thoracic surgeons and the society of cardiovascular anesthesiologists clinical practice guideline
-
Ferraris, V.A., Ferraris, S.P., Saha, S.P., Hessel, E.A. II., Haan, C.K., Royston, B.D., Bridges, C.R., Higgins, R.S.D., Despotis, G., Brown, J.R., Spiess, B.D., Shore-Lesserson, L., Stafford-Smith, M., Mazer, C.D., Bennett-Guerrero, E., Hill, S.E., Body, S., Society of Thoracic Surgeons Blood Conservation Guideline Task Force. Perioperative blood transfusion and blood conservation in cardiac surgery: the society of thoracic surgeons and the society of cardiovascular anesthesiologists clinical practice guideline. Annals of Thoracic Surgery 83 (2007), 27–86.
-
(2007)
Annals of Thoracic Surgery
, vol.83
, pp. 27-86
-
-
Ferraris, V.A.1
Ferraris, S.P.2
Saha, S.P.3
Hessel, E.A.4
Haan, C.K.5
Royston, B.D.6
Bridges, C.R.7
Higgins, R.S.D.8
Despotis, G.9
Brown, J.R.10
Spiess, B.D.11
Shore-Lesserson, L.12
Stafford-Smith, M.13
Mazer, C.D.14
Bennett-Guerrero, E.15
Hill, S.E.16
Body, S.17
-
2
-
-
4644223584
-
Home prothrombin time monitoring: a literature analysis
-
Yang, D.T., Robetorye, R.S., Rodgers, G.M., Home prothrombin time monitoring: a literature analysis. American Journal of Hematology 77 (2004), 177–186.
-
(2004)
American Journal of Hematology
, vol.77
, pp. 177-186
-
-
Yang, D.T.1
Robetorye, R.S.2
Rodgers, G.M.3
-
3
-
-
33645525914
-
Wintrobe's Clinical Hematology
-
12th ed. Lippincott Williams & Wilkins Philadelphia, PA
-
Greer, J.P., Foerster, J., Rodgers, G.M., Paraskevas, F., Glader, B., Arber, D.A., Means, R.T., Wintrobe's Clinical Hematology. 12th ed., 2008, Lippincott Williams & Wilkins, Philadelphia, PA.
-
(2008)
-
-
Greer, J.P.1
Foerster, J.2
Rodgers, G.M.3
Paraskevas, F.4
Glader, B.5
Arber, D.A.6
Means, R.T.7
-
4
-
-
0346435111
-
JBC Centennial 1905–2005 – 100 years of biochemistry and molecular biology – a brief historical review of the waterfall/cascade of blood coagulation
-
Davie, E.W., JBC Centennial 1905–2005 – 100 years of biochemistry and molecular biology – a brief historical review of the waterfall/cascade of blood coagulation. Journal of Biological Chemistry 278 (2003), 50819–50832.
-
(2003)
Journal of Biological Chemistry
, vol.278
, pp. 50819-50832
-
-
Davie, E.W.1
-
5
-
-
4344667310
-
The blood coagulation cascade
-
Schenone, M., Furie, B.C., Furie, B., The blood coagulation cascade. Current Opinion in Hematology 11 (2004), 272–277.
-
(2004)
Current Opinion in Hematology
, vol.11
, pp. 272-277
-
-
Schenone, M.1
Furie, B.C.2
Furie, B.3
-
6
-
-
50449147939
-
Effect of anti-hemophilic factor on one-stage clotting tests; a presumptive test for hemophilia and a simple one-stage anti-hemophilic factor assay procedure
-
Langdell, R., Wagner, R., Brinkhous, K., Effect of anti-hemophilic factor on one-stage clotting tests; a presumptive test for hemophilia and a simple one-stage anti-hemophilic factor assay procedure. Journal of Laboratory and Clinical Medicine 41 (1953), 637–647.
-
(1953)
Journal of Laboratory and Clinical Medicine
, vol.41
, pp. 637-647
-
-
Langdell, R.1
Wagner, R.2
Brinkhous, K.3
-
7
-
-
4444247754
-
The partial thromboplastin time: defining an era in coagulation
-
White, G.C., The partial thromboplastin time: defining an era in coagulation. Journal of Thrombosis and Haemostasis 1 (2003), 2267–2270.
-
(2003)
Journal of Thrombosis and Haemostasis
, vol.1
, pp. 2267-2270
-
-
White, G.C.1
-
8
-
-
0014471015
-
Control of heparin therapy. Sensitivity of activated partial thromboplastin time for monitoring antithrombotic effects of heparin
-
Zucker, S., Cathey, M.H., Control of heparin therapy. Sensitivity of activated partial thromboplastin time for monitoring antithrombotic effects of heparin. Journal of Laboratory and Clinical Medicine, 73, 1969, 320.
-
(1969)
Journal of Laboratory and Clinical Medicine
, vol.73
, pp. 320
-
-
Zucker, S.1
Cathey, M.H.2
-
9
-
-
0019770978
-
Laboratory monitoring of heparin. Effect of reagents and instruments in the activated partial thromboplastin time
-
Brandt, J.T., Triplett, D.A., Laboratory monitoring of heparin. Effect of reagents and instruments in the activated partial thromboplastin time. American Journal of Clinical Pathology, 76, 1981.
-
(1981)
American Journal of Clinical Pathology
, vol.76
-
-
Brandt, J.T.1
Triplett, D.A.2
-
10
-
-
0028742266
-
Overview of a novel point of care instrument system for measuring whole blood prothrombin time
-
Carpenter, G.P., Neel, T.G., Parker, J.R., Overview of a novel point of care instrument system for measuring whole blood prothrombin time. Proceedings of the Society of Photo-Optical Instrumentation Engineering 2136 (1994), 205–213.
-
(1994)
Proceedings of the Society of Photo-Optical Instrumentation Engineering
, vol.2136
, pp. 205-213
-
-
Carpenter, G.P.1
Neel, T.G.2
Parker, J.R.3
-
11
-
-
77957153668
-
Microfluidic system based on thermal expandable polymer for on chip blood coagulation testing
-
Metref, L., Bianchi, F., Vallet, V., Blanc, N., Goetschmann, R., Renaud, P., Microfluidic system based on thermal expandable polymer for on chip blood coagulation testing. Micro and Nanosystems 1 (2009), 41–45.
-
(2009)
Micro and Nanosystems
, vol.1
, pp. 41-45
-
-
Metref, L.1
Bianchi, F.2
Vallet, V.3
Blanc, N.4
Goetschmann, R.5
Renaud, P.6
-
12
-
-
0037403257
-
Monitoring blood coagulation with magnetoelastic sensors
-
Puckett, L.G., Barrett, G., Kouzoudis, D., Grimes, C., Bachas, L.G., Monitoring blood coagulation with magnetoelastic sensors. Biosensors & Bioelectronics 18 (2003), 675–681.
-
(2003)
Biosensors & Bioelectronics
, vol.18
, pp. 675-681
-
-
Puckett, L.G.1
Barrett, G.2
Kouzoudis, D.3
Grimes, C.4
Bachas, L.G.5
-
13
-
-
20444461522
-
Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces
-
Andersson, M., Andersson, J., Sellborn, A., Berglin, M., Nilsson, B., Elwing, H., Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces. Biosensors & Bioelectronics 21 (2005), 79–86.
-
(2005)
Biosensors & Bioelectronics
, vol.21
, pp. 79-86
-
-
Andersson, M.1
Andersson, J.2
Sellborn, A.3
Berglin, M.4
Nilsson, B.5
Elwing, H.6
-
14
-
-
0013277543
-
Measurement of the electrical resistance of human blood used in coagulation studies and cell volume determinations
-
Rosenthal, R.L., Tobias, C.W., Measurement of the electrical resistance of human blood used in coagulation studies and cell volume determinations. Journal of Laboratory and Clinical Medicine 33 (1948), 1110–1122.
-
(1948)
Journal of Laboratory and Clinical Medicine
, vol.33
, pp. 1110-1122
-
-
Rosenthal, R.L.1
Tobias, C.W.2
-
15
-
-
0014953835
-
Changes in the electrical impedance of blood during coagulation
-
Ur, A., Changes in the electrical impedance of blood during coagulation. Nature 226 (1970), 269–270.
-
(1970)
Nature
, vol.226
, pp. 269-270
-
-
Ur, A.1
-
16
-
-
85040757269
-
Portable prothrombin time test apparatus and associated method of performing a prothrombin time test
-
International Technidyne Corporation USA
-
Gavin, M., Cimini, C.M., Huang, M., Anthony Kuklo, J., Mawhirt, J.A., Marcelino, E., Simone, A., Portable prothrombin time test apparatus and associated method of performing a prothrombin time test. USPO, 1997, International Technidyne Corporation, USA.
-
(1997)
USPO
-
-
Gavin, M.1
Cimini, C.M.2
Huang, M.3
Anthony Kuklo, J.4
Mawhirt, J.A.5
Marcelino, E.6
Simone, A.7
-
17
-
-
33746224336
-
On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system
-
Song, H., Li, H.-W., Munson, M.S., Van Ha, T.G., Ismagilov, R.F., On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system. Analytical Chemistry 78 (2006), 4839–4849.
-
(2006)
Analytical Chemistry
, vol.78
, pp. 4839-4849
-
-
Song, H.1
Li, H.-W.2
Munson, M.S.3
Van Ha, T.G.4
Ismagilov, R.F.5
-
18
-
-
0006021049
-
Coagulation testing. Part 1. Current methods and challenges
-
Carville, D.G.M., Guyer, K.E., Coagulation testing. Part 1. Current methods and challenges. IVD Technology 4 (1998), 59–66.
-
(1998)
IVD Technology
, vol.4
, pp. 59-66
-
-
Carville, D.G.M.1
Guyer, K.E.2
-
19
-
-
0006096319
-
Coagulation testing. Part 2. The quest to optimize near-patient analyzers
-
Carville, D.G.M., Guyer, K.E., Coagulation testing. Part 2. The quest to optimize near-patient analyzers. IVD Technology 4 (1998), 33–40.
-
(1998)
IVD Technology
, vol.4
, pp. 33-40
-
-
Carville, D.G.M.1
Guyer, K.E.2
-
20
-
-
85040751883
-
Point-of-care I.V.Ds: overcoming the hurdles to market
-
Tsakeris, T.M., Point-of-care I.V.Ds: overcoming the hurdles to market. IVD Technology 5 (1999), 22–25.
-
(1999)
IVD Technology
, vol.5
, pp. 22-25
-
-
Tsakeris, T.M.1
-
21
-
-
0030152024
-
New applications of electrical impedance of human blood
-
Zhao, T.-X., New applications of electrical impedance of human blood. Journal of Medical Engineering & Technology 20 (1996), 115–120.
-
(1996)
Journal of Medical Engineering & Technology
, vol.20
, pp. 115-120
-
-
Zhao, T.-X.1
-
22
-
-
0028035448
-
A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate
-
Cha, K., et al. A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate. Physiological Measurement, 15, 1994, 499.
-
(1994)
Physiological Measurement
, vol.15
, pp. 499
-
-
Cha, K.1
-
23
-
-
0028298537
-
An electronic method for rapid measurement of haematocrit in blood samples
-
Cha, K., et al. An electronic method for rapid measurement of haematocrit in blood samples. Physiological Measurement, 15, 1994, 129.
-
(1994)
Physiological Measurement
, vol.15
, pp. 129
-
-
Cha, K.1
-
24
-
-
0017405882
-
Analysis and interpretation of the impedance blood coagulation curve
-
Ur, A., Analysis and interpretation of the impedance blood coagulation curve. American Journal of Clinical Pathology 67 (1977), 470–476.
-
(1977)
American Journal of Clinical Pathology
, vol.67
, pp. 470-476
-
-
Ur, A.1
-
25
-
-
80455163845
-
The conductivity of blood in coagulation
-
Wilson, T.M., The conductivity of blood in coagulation. Biochemical Journal 2 (1907), 377–382.
-
(1907)
Biochemical Journal
, vol.2
, pp. 377-382
-
-
Wilson, T.M.1
-
26
-
-
0016532670
-
The continuous measurement of resistivity and permittivity of human blood plasma during coagulation
-
Connelly, J.A., Buckler, M.J., The continuous measurement of resistivity and permittivity of human blood plasma during coagulation. Medical & Biological Engineering 13 (1975), 523–530.
-
(1975)
Medical & Biological Engineering
, vol.13
, pp. 523-530
-
-
Connelly, J.A.1
Buckler, M.J.2
-
27
-
-
0037799666
-
Electrical impedance measurement as an endpoint detection method for routine coagulation tests
-
Spence, N., Electrical impedance measurement as an endpoint detection method for routine coagulation tests. British Journal of Biomedical Science 59 (2002), 223–227.
-
(2002)
British Journal of Biomedical Science
, vol.59
, pp. 223-227
-
-
Spence, N.1
-
28
-
-
0346370876
-
The electrical properties of human blood during coagulation
-
Mungall, A.G., Morris, D., Martin, W.S., The electrical properties of human blood during coagulation. Medical Services Journal, Canada, 15, 1959.
-
(1959)
Medical Services Journal, Canada
, vol.15
-
-
Mungall, A.G.1
Morris, D.2
Martin, W.S.3
-
29
-
-
0023143522
-
Whole blood clotting tests – an evaluation of five methods
-
Blair, S.D., Menashi, S., Samson, D., Greenhalgh, R.M., Whole blood clotting tests – an evaluation of five methods. Clinical and Laboratory Haematology 9 (1987), 91–94.
-
(1987)
Clinical and Laboratory Haematology
, vol.9
, pp. 91-94
-
-
Blair, S.D.1
Menashi, S.2
Samson, D.3
Greenhalgh, R.M.4
-
30
-
-
37049227845
-
Electrical resistance of whole blood
-
Graff, S., Voorhees, A.B., Blakemore, A.H., Electrical resistance of whole blood. Science 106 (1947), 68–69.
-
(1947)
Science
, vol.106
, pp. 68-69
-
-
Graff, S.1
Voorhees, A.B.2
Blakemore, A.H.3
-
31
-
-
78649709711
-
A new approach to estimate venous thrombosis risk
-
Hayashi, Y., Katsumoto, Y., Omori, S., Yasuda, A., Asami, K., Kaibara, M., Uchimura, I., Dielectric Coagulometry, A new approach to estimate venous thrombosis risk. Analytical Chemistry 82 (2010), 9769–9774.
-
(2010)
Analytical Chemistry
, vol.82
, pp. 9769-9774
-
-
Hayashi, Y.1
Katsumoto, Y.2
Omori, S.3
Yasuda, A.4
Asami, K.5
Kaibara, M.6
Uchimura, I.7
Dielectric Coagulometry8
-
32
-
-
0242715868
-
The electrical conductivity of blood. i. Relationship to erythrocyte concentration
-
Hirsch, F.G., Texter, E.C., Wood, L.A., Ballard, W.C., Horan, F.E., Wright, I.S., Frey, C., Starr, D., The electrical conductivity of blood. i. Relationship to erythrocyte concentration. Blood 5 (1950), 1017–1035.
-
(1950)
Blood
, vol.5
, pp. 1017-1035
-
-
Hirsch, F.G.1
Texter, E.C.2
Wood, L.A.3
Ballard, W.C.4
Horan, F.E.5
Wright, I.S.6
Frey, C.7
Starr, D.8
-
33
-
-
9544252360
-
Electrolytic resistance of the blood clot
-
Henstell, H.H., Electrolytic resistance of the blood clot. American Journal of Physiology 158 (1949), 367–378.
-
(1949)
American Journal of Physiology
, vol.158
, pp. 367-378
-
-
Henstell, H.H.1
-
34
-
-
78651007045
-
Electrolytic resistance of the blood clot – resistance clotting time, onset of clot retraction and the clot resistance
-
Henstell, H.H., Electrolytic resistance of the blood clot – resistance clotting time, onset of clot retraction and the clot resistance. American Journal of Physiology 158 (1949), 379–386.
-
(1949)
American Journal of Physiology
, vol.158
, pp. 379-386
-
-
Henstell, H.H.1
-
36
-
-
0034711410
-
From micro- to nanofabrication with soft materials
-
Quake, S.R., Scherer, A., From micro- to nanofabrication with soft materials. Science 290 (2000), 1536–1540.
-
(2000)
Science
, vol.290
, pp. 1536-1540
-
-
Quake, S.R.1
Scherer, A.2
-
37
-
-
0032403465
-
Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
-
Duffy, D.C., McDonald, J.C., Schueller, O.J.A., Whitesides, G.M., Rapid prototyping of microfluidic systems in poly(dimethylsiloxane). Analytical Chemistry 70 (1998), 4974–4984.
-
(1998)
Analytical Chemistry
, vol.70
, pp. 4974-4984
-
-
Duffy, D.C.1
McDonald, J.C.2
Schueller, O.J.A.3
Whitesides, G.M.4
-
38
-
-
77749333437
-
Soft lithography for micro- and nanoscale patterning
-
Qin, D., Xia, Y.N., Whitesides, G.M., Soft lithography for micro- and nanoscale patterning. Nature Protocols 5 (2010), 491–502.
-
(2010)
Nature Protocols
, vol.5
, pp. 491-502
-
-
Qin, D.1
Xia, Y.N.2
Whitesides, G.M.3
-
39
-
-
71449126877
-
A power-free blood plasma extraction device based on planar crossflow filter microstructure
-
A power-free blood plasma extraction device based on planar crossflow filter microstructure. Kim, Y.C., Kim, S.-H., Heo, P.W., Park, J.-K., (eds.) Solid-State Sensors, Actuators and Microsystems Conference, 2009. Transducers 2009. International, 2009, 920–923.
-
(2009)
Solid-State Sensors, Actuators and Microsystems Conference, 2009. Transducers 2009. International
, pp. 920-923
-
-
Kim, Y.C.1
Kim, S.-H.2
Heo, P.W.3
Park, J.-K.4
-
40
-
-
33748309124
-
Effects on wettability by surfactant accumulation/depletion in bulk polydimethylsiloxane (PDMS)
-
Seo, J., Lee, L.P., Effects on wettability by surfactant accumulation/depletion in bulk polydimethylsiloxane (PDMS). Sensors and Actuators B – Chemical 119 (2006), 192–198.
-
(2006)
Sensors and Actuators B – Chemical
, vol.119
, pp. 192-198
-
-
Seo, J.1
Lee, L.P.2
-
41
-
-
73449143825
-
Recent developments in PDMS surface modification for microfluidic devices
-
Zhou, J., Ellis, A.V., Voelcker, N.H., Recent developments in PDMS surface modification for microfluidic devices. Electrophoresis 31 (2010), 2–16.
-
(2010)
Electrophoresis
, vol.31
, pp. 2-16
-
-
Zhou, J.1
Ellis, A.V.2
Voelcker, N.H.3
-
42
-
-
68849084893
-
Convenient method for modifying poly(dimethylsiloxane) with poly(ethylene glycol) in microfluidics
-
Zhou, J., Yan, H., Ren, K., Dai, W., Wu, H., Convenient method for modifying poly(dimethylsiloxane) with poly(ethylene glycol) in microfluidics. Analytical Chemistry 81 (2009), 6627–6632.
-
(2009)
Analytical Chemistry
, vol.81
, pp. 6627-6632
-
-
Zhou, J.1
Yan, H.2
Ren, K.3
Dai, W.4
Wu, H.5
-
43
-
-
24144448077
-
A simple low-cost lock-in amplifier for the laboratory
-
Sengupta, S.K., Farnham, J.M., Whitten, J.E., A simple low-cost lock-in amplifier for the laboratory. Journal of Chemical Education 82 (2005), 1399–1401.
-
(2005)
Journal of Chemical Education
, vol.82
, pp. 1399-1401
-
-
Sengupta, S.K.1
Farnham, J.M.2
Whitten, J.E.3
-
44
-
-
0017179363
-
New aspects of blood-clotting and thrombosis – investigations with method of rheosimulation
-
Hartert, H.H., New aspects of blood-clotting and thrombosis – investigations with method of rheosimulation. Thrombosis Research 8 (1976), 381–392.
-
(1976)
Thrombosis Research
, vol.8
, pp. 381-392
-
-
Hartert, H.H.1
-
45
-
-
4043104812
-
Enumeration of circulating tumor cells in the blood of breast cancer patients after filtration enrichment: correlation with disease stage
-
Kahn, H.J., Presta, A., Yang, L.Y., Blondal, J., Trudeau, M., Lickley, L., Holloway, C., McCready, D.R., Maclean, D., Marks, A., Enumeration of circulating tumor cells in the blood of breast cancer patients after filtration enrichment: correlation with disease stage. Breast Cancer Research And Treatment 86 (2004), 237–247.
-
(2004)
Breast Cancer Research And Treatment
, vol.86
, pp. 237-247
-
-
Kahn, H.J.1
Presta, A.2
Yang, L.Y.3
Blondal, J.4
Trudeau, M.5
Lickley, L.6
Holloway, C.7
McCready, D.R.8
Maclean, D.9
Marks, A.10
|