메뉴 건너뛰기




Volumn 180, Issue , 2013, Pages 21-27

Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing

Author keywords

APTT; Blood coagulation; Coagulometry; Heparin; Impedance; Point of care

Indexed keywords

COAGULATION; DIAGNOSIS; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; FLUIDIC DEVICES; MICROFLUIDICS; PATIENT TREATMENT; POLYDIMETHYLSILOXANE; POLYSACCHARIDES; SILICONES;

EID: 82955199998     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.11.031     Document Type: Article
Times cited : (55)

References (45)
  • 4
    • 0346435111 scopus 로고    scopus 로고
    • JBC Centennial 1905–2005 – 100 years of biochemistry and molecular biology – a brief historical review of the waterfall/cascade of blood coagulation
    • Davie, E.W., JBC Centennial 1905–2005 – 100 years of biochemistry and molecular biology – a brief historical review of the waterfall/cascade of blood coagulation. Journal of Biological Chemistry 278 (2003), 50819–50832.
    • (2003) Journal of Biological Chemistry , vol.278 , pp. 50819-50832
    • Davie, E.W.1
  • 6
    • 50449147939 scopus 로고
    • Effect of anti-hemophilic factor on one-stage clotting tests; a presumptive test for hemophilia and a simple one-stage anti-hemophilic factor assay procedure
    • Langdell, R., Wagner, R., Brinkhous, K., Effect of anti-hemophilic factor on one-stage clotting tests; a presumptive test for hemophilia and a simple one-stage anti-hemophilic factor assay procedure. Journal of Laboratory and Clinical Medicine 41 (1953), 637–647.
    • (1953) Journal of Laboratory and Clinical Medicine , vol.41 , pp. 637-647
    • Langdell, R.1    Wagner, R.2    Brinkhous, K.3
  • 7
    • 4444247754 scopus 로고    scopus 로고
    • The partial thromboplastin time: defining an era in coagulation
    • White, G.C., The partial thromboplastin time: defining an era in coagulation. Journal of Thrombosis and Haemostasis 1 (2003), 2267–2270.
    • (2003) Journal of Thrombosis and Haemostasis , vol.1 , pp. 2267-2270
    • White, G.C.1
  • 8
    • 0014471015 scopus 로고
    • Control of heparin therapy. Sensitivity of activated partial thromboplastin time for monitoring antithrombotic effects of heparin
    • Zucker, S., Cathey, M.H., Control of heparin therapy. Sensitivity of activated partial thromboplastin time for monitoring antithrombotic effects of heparin. Journal of Laboratory and Clinical Medicine, 73, 1969, 320.
    • (1969) Journal of Laboratory and Clinical Medicine , vol.73 , pp. 320
    • Zucker, S.1    Cathey, M.H.2
  • 9
    • 0019770978 scopus 로고
    • Laboratory monitoring of heparin. Effect of reagents and instruments in the activated partial thromboplastin time
    • Brandt, J.T., Triplett, D.A., Laboratory monitoring of heparin. Effect of reagents and instruments in the activated partial thromboplastin time. American Journal of Clinical Pathology, 76, 1981.
    • (1981) American Journal of Clinical Pathology , vol.76
    • Brandt, J.T.1    Triplett, D.A.2
  • 11
    • 77957153668 scopus 로고    scopus 로고
    • Microfluidic system based on thermal expandable polymer for on chip blood coagulation testing
    • Metref, L., Bianchi, F., Vallet, V., Blanc, N., Goetschmann, R., Renaud, P., Microfluidic system based on thermal expandable polymer for on chip blood coagulation testing. Micro and Nanosystems 1 (2009), 41–45.
    • (2009) Micro and Nanosystems , vol.1 , pp. 41-45
    • Metref, L.1    Bianchi, F.2    Vallet, V.3    Blanc, N.4    Goetschmann, R.5    Renaud, P.6
  • 13
    • 20444461522 scopus 로고    scopus 로고
    • Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces
    • Andersson, M., Andersson, J., Sellborn, A., Berglin, M., Nilsson, B., Elwing, H., Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces. Biosensors & Bioelectronics 21 (2005), 79–86.
    • (2005) Biosensors & Bioelectronics , vol.21 , pp. 79-86
    • Andersson, M.1    Andersson, J.2    Sellborn, A.3    Berglin, M.4    Nilsson, B.5    Elwing, H.6
  • 14
    • 0013277543 scopus 로고
    • Measurement of the electrical resistance of human blood used in coagulation studies and cell volume determinations
    • Rosenthal, R.L., Tobias, C.W., Measurement of the electrical resistance of human blood used in coagulation studies and cell volume determinations. Journal of Laboratory and Clinical Medicine 33 (1948), 1110–1122.
    • (1948) Journal of Laboratory and Clinical Medicine , vol.33 , pp. 1110-1122
    • Rosenthal, R.L.1    Tobias, C.W.2
  • 15
    • 0014953835 scopus 로고
    • Changes in the electrical impedance of blood during coagulation
    • Ur, A., Changes in the electrical impedance of blood during coagulation. Nature 226 (1970), 269–270.
    • (1970) Nature , vol.226 , pp. 269-270
    • Ur, A.1
  • 16
    • 85040757269 scopus 로고    scopus 로고
    • Portable prothrombin time test apparatus and associated method of performing a prothrombin time test
    • International Technidyne Corporation USA
    • Gavin, M., Cimini, C.M., Huang, M., Anthony Kuklo, J., Mawhirt, J.A., Marcelino, E., Simone, A., Portable prothrombin time test apparatus and associated method of performing a prothrombin time test. USPO, 1997, International Technidyne Corporation, USA.
    • (1997) USPO
    • Gavin, M.1    Cimini, C.M.2    Huang, M.3    Anthony Kuklo, J.4    Mawhirt, J.A.5    Marcelino, E.6    Simone, A.7
  • 17
    • 33746224336 scopus 로고    scopus 로고
    • On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system
    • Song, H., Li, H.-W., Munson, M.S., Van Ha, T.G., Ismagilov, R.F., On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system. Analytical Chemistry 78 (2006), 4839–4849.
    • (2006) Analytical Chemistry , vol.78 , pp. 4839-4849
    • Song, H.1    Li, H.-W.2    Munson, M.S.3    Van Ha, T.G.4    Ismagilov, R.F.5
  • 18
    • 0006021049 scopus 로고    scopus 로고
    • Coagulation testing. Part 1. Current methods and challenges
    • Carville, D.G.M., Guyer, K.E., Coagulation testing. Part 1. Current methods and challenges. IVD Technology 4 (1998), 59–66.
    • (1998) IVD Technology , vol.4 , pp. 59-66
    • Carville, D.G.M.1    Guyer, K.E.2
  • 19
    • 0006096319 scopus 로고    scopus 로고
    • Coagulation testing. Part 2. The quest to optimize near-patient analyzers
    • Carville, D.G.M., Guyer, K.E., Coagulation testing. Part 2. The quest to optimize near-patient analyzers. IVD Technology 4 (1998), 33–40.
    • (1998) IVD Technology , vol.4 , pp. 33-40
    • Carville, D.G.M.1    Guyer, K.E.2
  • 20
    • 85040751883 scopus 로고    scopus 로고
    • Point-of-care I.V.Ds: overcoming the hurdles to market
    • Tsakeris, T.M., Point-of-care I.V.Ds: overcoming the hurdles to market. IVD Technology 5 (1999), 22–25.
    • (1999) IVD Technology , vol.5 , pp. 22-25
    • Tsakeris, T.M.1
  • 21
    • 0030152024 scopus 로고    scopus 로고
    • New applications of electrical impedance of human blood
    • Zhao, T.-X., New applications of electrical impedance of human blood. Journal of Medical Engineering & Technology 20 (1996), 115–120.
    • (1996) Journal of Medical Engineering & Technology , vol.20 , pp. 115-120
    • Zhao, T.-X.1
  • 22
    • 0028035448 scopus 로고
    • A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate
    • Cha, K., et al. A new bioelectrical impedance method for measurement of the erythrocyte sedimentation rate. Physiological Measurement, 15, 1994, 499.
    • (1994) Physiological Measurement , vol.15 , pp. 499
    • Cha, K.1
  • 23
    • 0028298537 scopus 로고
    • An electronic method for rapid measurement of haematocrit in blood samples
    • Cha, K., et al. An electronic method for rapid measurement of haematocrit in blood samples. Physiological Measurement, 15, 1994, 129.
    • (1994) Physiological Measurement , vol.15 , pp. 129
    • Cha, K.1
  • 24
    • 0017405882 scopus 로고
    • Analysis and interpretation of the impedance blood coagulation curve
    • Ur, A., Analysis and interpretation of the impedance blood coagulation curve. American Journal of Clinical Pathology 67 (1977), 470–476.
    • (1977) American Journal of Clinical Pathology , vol.67 , pp. 470-476
    • Ur, A.1
  • 25
    • 80455163845 scopus 로고
    • The conductivity of blood in coagulation
    • Wilson, T.M., The conductivity of blood in coagulation. Biochemical Journal 2 (1907), 377–382.
    • (1907) Biochemical Journal , vol.2 , pp. 377-382
    • Wilson, T.M.1
  • 26
    • 0016532670 scopus 로고
    • The continuous measurement of resistivity and permittivity of human blood plasma during coagulation
    • Connelly, J.A., Buckler, M.J., The continuous measurement of resistivity and permittivity of human blood plasma during coagulation. Medical & Biological Engineering 13 (1975), 523–530.
    • (1975) Medical & Biological Engineering , vol.13 , pp. 523-530
    • Connelly, J.A.1    Buckler, M.J.2
  • 27
    • 0037799666 scopus 로고    scopus 로고
    • Electrical impedance measurement as an endpoint detection method for routine coagulation tests
    • Spence, N., Electrical impedance measurement as an endpoint detection method for routine coagulation tests. British Journal of Biomedical Science 59 (2002), 223–227.
    • (2002) British Journal of Biomedical Science , vol.59 , pp. 223-227
    • Spence, N.1
  • 30
    • 37049227845 scopus 로고
    • Electrical resistance of whole blood
    • Graff, S., Voorhees, A.B., Blakemore, A.H., Electrical resistance of whole blood. Science 106 (1947), 68–69.
    • (1947) Science , vol.106 , pp. 68-69
    • Graff, S.1    Voorhees, A.B.2    Blakemore, A.H.3
  • 33
    • 9544252360 scopus 로고
    • Electrolytic resistance of the blood clot
    • Henstell, H.H., Electrolytic resistance of the blood clot. American Journal of Physiology 158 (1949), 367–378.
    • (1949) American Journal of Physiology , vol.158 , pp. 367-378
    • Henstell, H.H.1
  • 34
    • 78651007045 scopus 로고
    • Electrolytic resistance of the blood clot – resistance clotting time, onset of clot retraction and the clot resistance
    • Henstell, H.H., Electrolytic resistance of the blood clot – resistance clotting time, onset of clot retraction and the clot resistance. American Journal of Physiology 158 (1949), 379–386.
    • (1949) American Journal of Physiology , vol.158 , pp. 379-386
    • Henstell, H.H.1
  • 36
    • 0034711410 scopus 로고    scopus 로고
    • From micro- to nanofabrication with soft materials
    • Quake, S.R., Scherer, A., From micro- to nanofabrication with soft materials. Science 290 (2000), 1536–1540.
    • (2000) Science , vol.290 , pp. 1536-1540
    • Quake, S.R.1    Scherer, A.2
  • 38
    • 77749333437 scopus 로고    scopus 로고
    • Soft lithography for micro- and nanoscale patterning
    • Qin, D., Xia, Y.N., Whitesides, G.M., Soft lithography for micro- and nanoscale patterning. Nature Protocols 5 (2010), 491–502.
    • (2010) Nature Protocols , vol.5 , pp. 491-502
    • Qin, D.1    Xia, Y.N.2    Whitesides, G.M.3
  • 40
    • 33748309124 scopus 로고    scopus 로고
    • Effects on wettability by surfactant accumulation/depletion in bulk polydimethylsiloxane (PDMS)
    • Seo, J., Lee, L.P., Effects on wettability by surfactant accumulation/depletion in bulk polydimethylsiloxane (PDMS). Sensors and Actuators B – Chemical 119 (2006), 192–198.
    • (2006) Sensors and Actuators B – Chemical , vol.119 , pp. 192-198
    • Seo, J.1    Lee, L.P.2
  • 41
    • 73449143825 scopus 로고    scopus 로고
    • Recent developments in PDMS surface modification for microfluidic devices
    • Zhou, J., Ellis, A.V., Voelcker, N.H., Recent developments in PDMS surface modification for microfluidic devices. Electrophoresis 31 (2010), 2–16.
    • (2010) Electrophoresis , vol.31 , pp. 2-16
    • Zhou, J.1    Ellis, A.V.2    Voelcker, N.H.3
  • 42
    • 68849084893 scopus 로고    scopus 로고
    • Convenient method for modifying poly(dimethylsiloxane) with poly(ethylene glycol) in microfluidics
    • Zhou, J., Yan, H., Ren, K., Dai, W., Wu, H., Convenient method for modifying poly(dimethylsiloxane) with poly(ethylene glycol) in microfluidics. Analytical Chemistry 81 (2009), 6627–6632.
    • (2009) Analytical Chemistry , vol.81 , pp. 6627-6632
    • Zhou, J.1    Yan, H.2    Ren, K.3    Dai, W.4    Wu, H.5
  • 44
    • 0017179363 scopus 로고
    • New aspects of blood-clotting and thrombosis – investigations with method of rheosimulation
    • Hartert, H.H., New aspects of blood-clotting and thrombosis – investigations with method of rheosimulation. Thrombosis Research 8 (1976), 381–392.
    • (1976) Thrombosis Research , vol.8 , pp. 381-392
    • Hartert, H.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.