메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Multiterminal HVDC-VSC for offshore wind power integration

Author keywords

High voltage direct current (HVDC); Multiterminal HVDC; Offshore wind power; Wind power generation

Indexed keywords

CONTROL SCHEMES; DC VOLTAGE; DROOP CONTROL; HIGH VOLTAGE DIRECT CURRENT; INJECTED POWER; MULTI TERMINALS; MULTI-TERMINAL HVDC; NORMAL OPERATIONS; OFFSHORE WIND FARMS; OFFSHORE WIND POWER; OPERATION MODE; TERMINAL SYSTEMS; VOLTAGE SAGS; VOLTAGE SOURCE; WIND FARM; WIND SPEED;

EID: 82855169166     PISSN: 19449925     EISSN: 19449933     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2011.6039238     Document Type: Conference Paper
Times cited : (44)

References (17)
  • 1
    • 0036968466 scopus 로고    scopus 로고
    • Transmission systems for offshore wind farms
    • Dec.
    • T. Ackermann, "Transmission systems for offshore wind farms," IEEE Power Engineering Review, vol. 22, no. 12, pp. 23-27, Dec. 2002.
    • (2002) IEEE Power Engineering Review , vol.22 , Issue.12 , pp. 23-27
    • Ackermann, T.1
  • 3
    • 34548028754 scopus 로고    scopus 로고
    • Grid integration of large DFIG-based wind farms using VSC transmission
    • DOI 10.1109/TPWRS.2007.901306
    • L. Xu, L. Yao, and C. Sasse, "Grid integration of large DFIG-based wind farms using VSC transmission," IEEE Transactions on Power Systems, vol. 22, no. 3, pp. 976-984, 2007. (Pubitemid 47278357)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.3 , pp. 976-984
    • Xu, L.1    Yao, L.2    Sasse, C.3
  • 4
    • 33746097798 scopus 로고    scopus 로고
    • Grid connection of large offshore wind farms using HVDC
    • DOI 10.1002/we.185
    • L. Xu and B. Andersen, "Grid connection of large offshore wind farms using HVDC," Wind Energy, vol. 9, no. 4, pp. 371-382, 2006. (Pubitemid 44073981)
    • (2006) Wind Energy , vol.9 , Issue.4 , pp. 371-382
    • Xu, L.1    Andersen, B.R.2
  • 5
    • 68349154337 scopus 로고    scopus 로고
    • Enhanced fault rid-through method for wind farms connected to the grid through vsc-based hvdc transmission
    • C. Feltes, H. Wrede, F. Koch, and I. Erlich, "Enhanced fault rid-through method for wind farms connected to the grid through vsc-based hvdc transmission," IEEE Transactions on Power Systems, vol. 24, no. 3, pp. 1537-1546, 2009.
    • (2009) IEEE Transactions on Power Systems , vol.24 , Issue.3 , pp. 1537-1546
    • Feltes, C.1    Wrede, H.2    Koch, F.3    Erlich, I.4
  • 6
    • 36349014394 scopus 로고    scopus 로고
    • Control of an HVdc link connecting a wind farm to the grid for fault ride-through enhancement
    • DOI 10.1109/TPWRS.2007.907377
    • T. Vrionis, X. Koutiva, N. Vovos, and G. Giannakopoulos, "Control of an HVDC link connecting a wind farm to the grid for fault ride-through enhancement," IEEE Transactions on Power Systems, vol. 22, no. 4, pp. 2039-2047, 2007. (Pubitemid 350142005)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.4 , pp. 2039-2047
    • Vrionis, T.D.1    Koutiva, X.I.2    Vovos, N.A.3    Giannakopoulos, G.B.4
  • 7
    • 67650066305 scopus 로고    scopus 로고
    • Simulated onshore-fault ride through of offshore wind farms connected through VSC HVDC
    • A. Arulampalam, G. Ramtharan, N. Caliao, J. Ekanayake, and N. Jenkins, "Simulated onshore-fault ride through of offshore wind farms connected through VSC HVDC," Wind Engineering, vol. 32, no. 2, pp. 103-113, 2008.
    • (2008) Wind Engineering , vol.32 , Issue.2 , pp. 103-113
    • Arulampalam, A.1    Ramtharan, G.2    Caliao, N.3    Ekanayake, J.4    Jenkins, N.5
  • 10
    • 0037252848 scopus 로고    scopus 로고
    • Optimal acquisition and aggregation of offshore wind power by multiterminal voltage source hvdc
    • W. Lu and B.-T. Ooi, "Optimal acquisition and aggregation of offshore wind power by multiterminal voltage source hvdc," IEEE Transactions on Power Delivery, vol. 18, no. 1, pp. 201-206, 2003.
    • (2003) IEEE Transactions on Power Delivery , vol.18 , Issue.1 , pp. 201-206
    • Lu, W.1    Ooi, B.-T.2
  • 14
    • 77954029640 scopus 로고    scopus 로고
    • Maximum generation power evaluation of variable frequency offshore wind farms when connected to a single power converter
    • O. Gomis-Bellmunt, A. Junyent-Ferre, A. Sumper, and S. Galceran-Arellano, "Maximum generation power evaluation of variable frequency offshore wind farms when connected to a single power converter,"Applied Energy, vol. 87, pp. 3103-3109, 2010.
    • (2010) Applied Energy , vol.87 , pp. 3103-3109
    • Gomis-Bellmunt, O.1    Junyent-Ferre, A.2    Sumper, A.3    Galceran-Arellano, S.4
  • 15
    • 39149115395 scopus 로고    scopus 로고
    • Offshore wind farm with a series multiterminal CSI HVDC
    • DOI 10.1016/j.epsr.2007.05.023, PII S0378779607001332
    • D. Jovcic, "Offshore wind farm with a series multiterminal CSI HVDC,"Electric Power Systems Research, vol. 78, pp. 747-755, 2008. (Pubitemid 351258233)
    • (2008) Electric Power Systems Research , vol.78 , Issue.4 , pp. 747-755
    • Jovcic, D.1
  • 17
    • 0031699562 scopus 로고    scopus 로고
    • Model-based current control of ac machines using the internal model control method
    • Jan.-Feb.
    • L. Harnefors and H.-P. Nee, "Model-based current control of ac machines using the internal model control method," IEEE Transactions on Industry Applications, vol. 34, no. 1, pp. 133-141, Jan.-Feb. 1998.
    • (1998) IEEE Transactions on Industry Applications , vol.34 , Issue.1 , pp. 133-141
    • Harnefors, L.1    Nee, H.-P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.