Volumn 22, Issue 3, 2007, Pages 976-984

Grid integration of large DFIG-based wind farms using VSC transmission

Author keywords

Converter; Doubly fed induction generator; Fault ride through; Frequency modulation; High voltage dc transmission (HVDC); Voltage source converter (VSC) transmission; Wind farm

Indexed keywords

ASYNCHRONOUS GENERATORS; COMPUTER SIMULATION; ELECTRIC CONVERTERS; ELECTRIC GENERATORS; FREQUENCY MODULATION; HVDC POWER TRANSMISSION; POWER GENERATION;

EID: 34548028754     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2007.901306     Document Type: Article
Times cited : (452)

References (16)
  • 1
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • May/Jun
    • S. Muller, M. Deicke, and R. W. De Doncker, "Doubly fed induction generator systems for wind turbines," IEEE Ind. Appl. Mag., vol. 8, no. 3, pp. 26-33, May/Jun. 2002.
    • (2002) IEEE Ind. Appl. Mag , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 2
    • 0030146394 scopus 로고    scopus 로고
    • Double fed induction generator using back-to-back PWM converter and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, and G. M. Asher, "Double fed induction generator using back-to-back PWM converter and its application to variablespeed wind-energy generation," Proc. Inst. Elect. Eng., Elect. Power Appl. vol. 143, no. 3, pp. 231-241, 1996.
    • (1996) Proc. Inst. Elect. Eng., Elect. Power Appl , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 7
    • 33645734726 scopus 로고    scopus 로고
    • Optimal integration of an offshore wind farm to a weak grid
    • Apr
    • X. I. Koutiva, T. D. Vrionis, N. A. Vovos, and G. B. Giannakopoulos, "Optimal integration of an offshore wind farm to a weak grid," IEEE Trans. Power Del., vol. 21, no. 2, pp. 987-994, Apr. 2006.
    • (2006) IEEE Trans. Power Del , vol.21 , Issue.2 , pp. 987-994
    • Koutiva, X.I.1    Vrionis, T.D.2    Vovos, N.A.3    Giannakopoulos, G.B.4
  • 8
    • 0037252848 scopus 로고    scopus 로고
    • Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
    • Jan
    • W. Lu and B. T. Ooi, "Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC," IEEE Trans. Power Del., vol. 18, no. 1, pp. 201-206, Jan. 2003.
    • (2003) IEEE Trans. Power Del , vol.18 , Issue.1 , pp. 201-206
    • Lu, W.1    Ooi, B.T.2
  • 9
    • 33746097798 scopus 로고    scopus 로고
    • Grid connection of large offshore wind farms using HVDC
    • Jul./Aug
    • L. Xu and B. R. Andersen, "Grid connection of large offshore wind farms using HVDC," Wind Energy, vol. 9, no. 4, pp. 371-382, Jul./Aug. 2006.
    • (2006) Wind Energy , vol.9 , Issue.4 , pp. 371-382
    • Xu, L.1    Andersen, B.R.2
  • 10
    • 0036609761 scopus 로고    scopus 로고
    • HVDC transmission for large offshore windfarms
    • Jun
    • N. Kirby, L. Xu, M. Lucket, and W. Siepmann, "HVDC transmission for large offshore windfarms," Inst. Elect. Eng. Power Eng. J., vol. 16, no. 3, pp. 135-141, Jun. 2002.
    • (2002) Inst. Elect. Eng. Power Eng. J , vol.16 , Issue.3 , pp. 135-141
    • Kirby, N.1    Xu, L.2    Lucket, M.3    Siepmann, W.4
  • 11
    • 33244491879 scopus 로고    scopus 로고
    • Coordinated control of an HVDC link and doubly fed induction generators in a large offshore wind farm
    • Jan
    • D. Xiang, L. Ran, J. R. Bumby, P. Tavner, and S. Yang, "Coordinated control of an HVDC link and doubly fed induction generators in a large offshore wind farm," IEEE Trans. Power Del., vol. 21, no. 1, pp. 463-471, Jan. 2006.
    • (2006) IEEE Trans. Power Del , vol.21 , Issue.1 , pp. 463-471
    • Xiang, D.1    Ran, L.2    Bumby, J.R.3    Tavner, P.4    Yang, S.5
  • 13
    • 0842287675 scopus 로고    scopus 로고
    • Analysis of a robust DC-bus voltage control system for a VSC transmission scheme
    • Nov
    • J. L. Thomas, S. Poullain, and A. Benchaib, "Analysis of a robust DC-bus voltage control system for a VSC transmission scheme," in Proc. 7th AC/DC Transmission Conf., Nov. 2001.
    • (2001) Proc. 7th AC/DC Transmission Conf
    • Thomas, J.L.1    Poullain, S.2    Benchaib, A.3
  • 14
    • 12544259253 scopus 로고    scopus 로고
    • VSC transmission system operating under unbalanced network conditions - Analysis and control design
    • Jan
    • L. Xu, B. R. Andersen, and P. Cartwright, "VSC transmission system operating under unbalanced network conditions - Analysis and control design," IEEE Trans. Power Del., vol. 20, no. 1, pp. 427-434, Jan. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.1 , pp. 427-434
    • Xu, L.1    Andersen, B.R.2    Cartwright, P.3
  • 15
    • 0029358709 scopus 로고
    • Advanced regular-sampled PWM control techniques for drives and static power converters
    • Aug
    • S. R. Bowes, "Advanced regular-sampled PWM control techniques for drives and static power converters," IEEE Trans. Ind. Electron., vol. 42, no. 4, pp. 367-373, Aug. 1995.
    • (1995) IEEE Trans. Ind. Electron , vol.42 , Issue.4 , pp. 367-373
    • Bowes, S.R.1
  • 16
    • 22044432503 scopus 로고    scopus 로고
    • Voltage dip ride through of a doubly-fed generator equipped with an active crowbar
    • Sweden, Mar
    • J. Niiranen, "Voltage dip ride through of a doubly-fed generator equipped with an active crowbar," in Proc. Nordic Wind Power Conf. Sweden, Mar. 2004.
    • (2004) Proc. Nordic Wind Power Conf
    • Niiranen, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.