메뉴 건너뛰기




Volumn 172, Issue 1, 2011, Pages 154-160

A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopy

Author keywords

Biological liquids; Biomedical transducers; Cortisol; Cortisol monitoring; Disposable biosensor; Dithiobis(succinimidyl propionate); Electrochemical impedance; Enzyme linked immunoassay (ELISA); Immunosensor; Interstitial fluid (ISF); Medical services; Self assembled monolayer (SAM); Stratum corneum

Indexed keywords

BIOLOGICAL LIQUIDS; BIOMEDICAL TRANSDUCERS; CORTISOL; DISPOSABLE BIOSENSOR; DITHIOBIS(SUCCINIMIDYL PROPIONATE); ELECTROCHEMICAL IMPEDANCE; ENZYME-LINKED IMMUNOASSAYS; INTERSTITIAL FLUIDS; MEDICAL SERVICES; SELF ASSEMBLED MONOLAYER (SAM); STRATUM CORNEUM;

EID: 82755161748     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2011.04.028     Document Type: Conference Paper
Times cited : (78)

References (25)
  • 1
    • 77952580963 scopus 로고    scopus 로고
    • Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol
    • 10.1016/j.bios.2010.03.016
    • S.K. Arya, G. Chornokur, M. Venugopal, and S. Bhansali Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol Biosens. Bioelectron. 25 2010 2296 2300 10.1016/j.bios.2010.03.016
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 2296-2300
    • Arya, S.K.1    Chornokur, G.2    Venugopal, M.3    Bhansali, S.4
  • 2
    • 78649572095 scopus 로고    scopus 로고
    • Antibody functionalized interdigitated μ-electrodes (IDμE's) based impedimetric cortisol biosensor
    • S.K. Arya, G. Chornokur, M. Venugopal, and S. Bhansali Antibody functionalized interdigitated μ-electrodes (IDμE's) based impedimetric cortisol biosensor Analyst 135 2010 1941 1946
    • (2010) Analyst , vol.135 , pp. 1941-1946
    • Arya, S.K.1    Chornokur, G.2    Venugopal, M.3    Bhansali, S.4
  • 3
    • 6044261446 scopus 로고    scopus 로고
    • A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements
    • DOI 10.1089/dia.2004.6.635
    • P.J. Stout, J.R. Racchini, and M.E. Hilgers A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements Diabetes Technol. Ther. 6 2004 635 644 (Pubitemid 39383070)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.5 , pp. 635-644
    • Stout, P.J.1    Racchini, J.R.2    Hilgers, M.E.3
  • 4
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • J.P. Bantle, and W. Thomas Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid J. Lab. Clin. Med. 130 1997 436 441 (Pubitemid 27498670)
    • (1997) Journal of Laboratory and Clinical Medicine , vol.130 , Issue.4 , pp. 436-441
    • Bantle, J.P.1    Thomas, W.2
  • 5
    • 0028067965 scopus 로고
    • Clinical usefulness of the glucose concentration in the subcutaneous tissue - Properties and pitfalls of electrochemical biosensors
    • U. Fischer, K. Rebrin, T. von Woedtke, and P. Abel Clinical usefulness of the glucose concentration in the subcutaneous tissue - properties and pitfalls of electrochemical biosensors Horm. Metab. Res. 26 1994 515 522 (Pubitemid 24352161)
    • (1994) Hormone and Metabolic Research , vol.26 , Issue.11 , pp. 515-522
    • Fischer, U.1    Rebrin, K.2    Woedtke, V.T.3    Abel, P.4
  • 6
    • 0029101233 scopus 로고
    • Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring
    • F. Sternberg, C. Meyerhoff, F.J. Mennel, F. Bischof, and E.F. Pfeiffer Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring Diabetes Care 18 1995 1266 1269
    • (1995) Diabetes Care , vol.18 , pp. 1266-1269
    • Sternberg, F.1    Meyerhoff, C.2    Mennel, F.J.3    Bischof, F.4    Pfeiffer, E.F.5
  • 8
    • 0033188401 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Long-term implantable sensor approach
    • G.Y. Daniloff Continuous glucose monitoring: long-term implantable sensor approach Diabetes Technol. Ther. 1 1999 261 266
    • (1999) Diabetes Technol. Ther. , vol.1 , pp. 261-266
    • Daniloff, G.Y.1
  • 9
    • 0031036953 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring
    • D.C. Klonoff Noninvasive blood glucose monitoring Diabetes Care 20 1997 433 437 (Pubitemid 27098238)
    • (1997) Diabetes Care , vol.20 , Issue.3 , pp. 433-437
    • Klonoff, D.C.1
  • 20
    • 0034293025 scopus 로고    scopus 로고
    • A golden age of clinical chemistry: 1948-1960
    • L. Rosenfeld A golden age of clinical chemistry: 1948-1960 Clin. Chem. 46 10 2000 1705 1714
    • (2000) Clin. Chem. , vol.46 , Issue.10 , pp. 1705-1714
    • Rosenfeld, L.1
  • 21
    • 47649087059 scopus 로고    scopus 로고
    • An immunoelectrochemical sensor for salivary cortisol measurement
    • K. Sun, N. Ramgir, and S. Bhansali An immunoelectrochemical sensor for salivary cortisol measurement Sens. Actuators B: Chem. 133 2008 533 537
    • (2008) Sens. Actuators B: Chem. , vol.133 , pp. 533-537
    • Sun, K.1    Ramgir, N.2    Bhansali, S.3
  • 25
    • 0016792972 scopus 로고
    • Rhythms of ACTH and corticosteroid secretion in health and disease and their experimental modification
    • D.T. Krieger Rhythms of ACTH and corticosteroid secretion in health and disease and their experimental modification J. Steroid Biochem. 6 1975 785 791
    • (1975) J. Steroid Biochem. , vol.6 , pp. 785-791
    • Krieger, D.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.