메뉴 건너뛰기




Volumn 32, Issue 12, 2011, Pages

Patient examinations using electrical impedance tomography - Sources of interference in the intensive care unit

Author keywords

continuous cardiac output monitoring; EIT; lung imaging; mechanical ventilation; pulsation therapy; ventilation distribution

Indexed keywords

BIOLOGICAL ORGANS; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTROMAGNETIC PULSE; HEART; INFORMATION FILTERING; INTENSIVE CARE UNITS; PATIENT MONITORING; PATIENT TREATMENT; VENTILATION;

EID: 82055198480     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/32/12/F01     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 70149113909 scopus 로고    scopus 로고
    • GREIT: A unified approach to 2D linear EIT reconstruction of lung images
    • Adler A et al 2009 GREIT: a unified approach to 2D linear EIT reconstruction of lung images Physiol. Meas. 30 S35-55
    • (2009) Physiol. Meas. , vol.30
    • Adler, A.1
  • 2
    • 0031280166 scopus 로고    scopus 로고
    • Imaging with electricity: Report of the European Concerted Action on Impedance Tomography
    • Boone K, Barber D and Brown B 1997 Imaging with electricity: report of the European Concerted Action on Impedance Tomography J. Med. Eng. Technol. 21 201-32 (Pubitemid 28012930)
    • (1997) Journal of Medical Engineering and Technology , vol.21 , Issue.6 , pp. 201-232
    • Boone, K.1    Barber, D.2    Brown, B.3
  • 3
    • 79958792452 scopus 로고    scopus 로고
    • The impact of electrode area, contact impedance and boundary shape on EIT images
    • Boyle A and Adler A 2011 The impact of electrode area, contact impedance and boundary shape on EIT images Physiol. Meas. 32 745-54
    • (2011) Physiol. Meas. , vol.32 , pp. 745-754
    • Boyle, A.1    Adler, A.2
  • 4
    • 78650417000 scopus 로고    scopus 로고
    • Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre
    • Dargaville P A, Rimensberger P C and Frerichs I 2010 Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre Intensive Care Med. 36 1953-61
    • (2010) Intensive Care Med. , vol.36 , pp. 1953-1961
    • Dargaville, P.A.1    Rimensberger, P.C.2    Frerichs, I.3
  • 5
    • 0034039948 scopus 로고    scopus 로고
    • Electrical impedance tomography (EIT) in applications related to lung and ventilation: A review of experimental and clinical activities
    • Frerichs I 2000 Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities Physiol. Meas. 21 R1-21
    • (2000) Physiol. Meas. , vol.21 , pp. 1-21
    • Frerichs, I.1
  • 6
    • 0036591482 scopus 로고    scopus 로고
    • Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging
    • DOI 10.1109/TMI.2002.800585, PII 1011092002800585, Electrical Impedance Tomography
    • Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M and Hellige G 2002 Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging IEEE Trans. Med. Imaging 21 646-52 (Pubitemid 34950083)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.6 , pp. 646-652
    • Frerichs, I.1    Hinz, J.2    Herrmann, P.3    Weisser, G.4    Hahn, G.5    Quintel, M.6    Hellige, G.7
  • 8
    • 78951471583 scopus 로고    scopus 로고
    • Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    • Grant C A, Pham T, Hough J, Riedel T, Stocker C and Schibler A 2011 Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography Crit. Care 15 R37
    • (2011) Crit. Care , vol.15 , pp. 37
    • Grant, C.A.1    Pham, T.2    Hough, J.3    Riedel, T.4    Stocker, C.5    Schibler, A.6
  • 10
    • 43049127187 scopus 로고    scopus 로고
    • Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography
    • DOI 10.1007/s00134-007-0786-9
    • Meier T, Luepschen H, Karsten J, Leibecke T, Grossherr M, Gehring H and Leonhardt S 2008 Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography Intensive Care Med. 34 543-50 (Pubitemid 351623019)
    • (2008) Intensive Care Medicine , vol.34 , Issue.3 , pp. 543-550
    • Meier, T.1    Luepschen, H.2    Karsten, J.3    Leibecke, T.4    Grossherr, M.5    Gehring, H.6    Leonhardt, S.7
  • 11
    • 79955640279 scopus 로고    scopus 로고
    • Lung impedance measurements to monitor alveolar ventilation
    • Moerer O, Hahn and Quintel M 2011 Lung impedance measurements to monitor alveolar ventilation Curr. Opin. Crit. Care 17 260-7
    • (2011) Curr. Opin. Crit. Care , vol.17 , pp. 260-267
    • Moerer, O.1    Hahn2    Quintel, M.3
  • 12
    • 33745133054 scopus 로고    scopus 로고
    • Imaging of conductivity changes and electrode movement in EIT
    • Soleimani M, Gómez-Laberge C and Adler A 2006 Imaging of conductivity changes and electrode movement in EIT Physiol. Meas. 27 S103-13
    • (2006) Physiol. Meas. , vol.27
    • Soleimani, M.1    Gómez-Laberge, C.2    Adler, A.3
  • 13
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • Yelderman M 1990 Continuous measurement of cardiac output with the use of stochastic system identification techniques J. Clin. Monit. 6 322-32 (Pubitemid 20374404)
    • (1990) Journal of Clinical Monitoring , vol.6 , Issue.4 , pp. 322-332
    • Yelderman, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.