메뉴 건너뛰기




Volumn 32, Issue 2, 2011, Pages 109-114

Point-of-care testing and creatinine measurement

Author keywords

[No Author keywords available]

Indexed keywords


EID: 82055189931     PISSN: 01598090     EISSN: 18380212     Source Type: Journal    
DOI: None     Document Type: Short Survey
Times cited : (68)

References (22)
  • 4
    • 36349006181 scopus 로고    scopus 로고
    • Measurement of serum creatinine - current status and future goals
    • Peake M, Whiting M. Measurement of serum creatinine - current status and future goals. Clin Biochem Rev 2006;27:173-84.
    • (2006) Clin Biochem Rev , vol.27 , pp. 173-184
    • Peake, M.1    Whiting, M.2
  • 5
    • 33747120659 scopus 로고    scopus 로고
    • Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate
    • Levey AS, Coresh J, Greene T, Stevens LA, Zhang YL, Hendriksen S, et al. Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate. Ann Intern Med 2006;145:247-54.
    • (2006) Ann Intern Med , vol.145 , pp. 247-254
    • Levey, A.S.1    Coresh, J.2    Greene, T.3    Stevens, L.A.4    Zhang, Y.L.5    Hendriksen, S.6
  • 6
    • 38449098541 scopus 로고    scopus 로고
    • Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: revised recommendations
    • Mathew TH, Johnson DW, Jones GR. Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: revised recommendations. Med J Aust 2007;187:459-63.
    • (2007) Med J Aust , vol.187 , pp. 459-463
    • Mathew, T.H.1    Johnson, D.W.2    Jones, G.R.3
  • 7
    • 29744469415 scopus 로고    scopus 로고
    • Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program
    • Myers GL, Miller WG, Coresh J, Fleming J, Greenberg N, Greene T, et al. Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem 2006;52:5-18.
    • (2006) Clin Chem , vol.52 , pp. 5-18
    • Myers, G.L.1    Miller, W.G.2    Coresh, J.3    Fleming, J.4    Greenberg, N.5    Greene, T.6
  • 8
    • 77952295042 scopus 로고    scopus 로고
    • Screening for chronic kidney disease in Australia: a pilot study in the community and workplace
    • Mathew TH, Corso O, Ludlow M, Boyle A, Cass A, Chadban SJ, et al. Screening for chronic kidney disease in Australia: a pilot study in the community and workplace. Kidney Int Suppl 2010;77(Suppl 116):S9-S16.
    • (2010) Kidney Int Suppl , vol.77 , Issue.SUPPL. 116
    • Mathew, T.H.1    Corso, O.2    Ludlow, M.3    Boyle, A.4    Cass, A.5    Chadban, S.J.6
  • 9
    • 77954315313 scopus 로고    scopus 로고
    • Evaluation of the analytical performance of the Nova StatSensor creatinine meter and reagent strip technology for whole blood testing
    • Schnabl KL, Bagherpoor S, Diker P, Cursio C, DuBois J, Yip PM. Evaluation of the analytical performance of the Nova StatSensor creatinine meter and reagent strip technology for whole blood testing. Clin Biochem 2010;43:1026-9.
    • (2010) Clin Biochem , vol.43 , pp. 1026-1029
    • Schnabl, K.L.1    Bagherpoor, S.2    Diker, P.3    Cursio, C.4    DuBois, J.5    Yip, P.M.6
  • 10
    • 82055176513 scopus 로고    scopus 로고
    • Evaluation of the GEM Premier 4000 for urea and creatinine analysis
    • Coll X, Rees C, Brownlee C, Spooner R. Evaluation of the GEM Premier 4000 for urea and creatinine analysis. Clin Biochem Rev 2010;31(Suppl):S28-9.
    • (2010) Clin Biochem Rev , vol.31 , Issue.SUPPL.
    • Coll, X.1    Rees, C.2    Brownlee, C.3    Spooner, R.4
  • 11
    • 77949441552 scopus 로고    scopus 로고
    • New chemistry cartridge for the GEM Premier 4000 critical care analyser, including electrochemical sensors for creatinine, urea, and measured bicarbonate
    • Cervera JM, Conant J. New chemistry cartridge for the GEM Premier 4000 critical care analyser, including electrochemical sensors for creatinine, urea, and measured bicarbonate. Point of Care 2010;9:1-7.
    • (2010) Point of Care , vol.9 , pp. 1-7
    • Cervera, J.M.1    Conant, J.2
  • 12
    • 0033374189 scopus 로고    scopus 로고
    • General strategies to set quality specifications for reliability performance characteristics
    • Fraser CG. General strategies to set quality specifications for reliability performance characteristics. Scand J Clin Lab Invest 1999;59:487-90.
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 487-490
    • Fraser, C.G.1
  • 15
    • 82055198324 scopus 로고    scopus 로고
    • RCPA Chemical Pathology QAP. Adelaide, South Australia
    • RCPA Chemical Pathology QAP. Participant handbook 2009. Adelaide, South Australia; 2009.
    • (2009) Participant handbook 2009
  • 16
    • 82055198321 scopus 로고    scopus 로고
    • Centre for Evidence-based Purchasing. Evaluation report. CEP10042. National Health Service, UK
    • Centre for Evidence-based Purchasing. Evaluation report. Point of care tests for the measurement of creatinine. CEP10042. National Health Service, UK; 2010.
    • (2010) Point of care tests for the measurement of creatinine
  • 19
    • 38349035800 scopus 로고    scopus 로고
    • New creatinine sensor for point-of-care testing of creatinine meets the National Kidney Disease Education Program guidelines
    • Skurup A, Kristensen T, Wennecke G. New creatinine sensor for point-of-care testing of creatinine meets the National Kidney Disease Education Program guidelines. Clin Chem Lab Med 2008;46:3-8.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 3-8
    • Skurup, A.1    Kristensen, T.2    Wennecke, G.3
  • 20
    • 72949086196 scopus 로고    scopus 로고
    • Comparison of three whole blood creatinine methods for estimation of glomerular filtration rate before radiographic contrast administration
    • Korpi-Steiner NL, Williamson EE, Karon BS. Comparison of three whole blood creatinine methods for estimation of glomerular filtration rate before radiographic contrast administration. Am J Clin Pathol 2009;132:920-6.
    • (2009) Am J Clin Pathol , vol.132 , pp. 920-926
    • Korpi-Steiner, N.L.1    Williamson, E.E.2    Karon, B.S.3
  • 21
    • 79958831894 scopus 로고    scopus 로고
    • Innovative use of point-of-care testing for chronic kidney disease screening
    • (in press)
    • Shephard A, Shephard M, Halls H, Corso O, Mathew T. Innovative use of point-of-care testing for chronic kidney disease screening. Point of Care 2011 (in press).
    • (2011) Point of Care
    • Shephard, A.1    Shephard, M.2    Halls, H.3    Corso, O.4    Mathew, T.5
  • 22
    • 77955464013 scopus 로고    scopus 로고
    • Assessment of the Nova StatSensor whole blood point-of-care creatinine analyzer for the measurement of kidney function in screening for chronic kidney disease
    • Shephard MD, Peake MJ, Corso O, Shephard A, Mazzachi B, Spaeth B, et al. Assessment of the Nova StatSensor whole blood point-of-care creatinine analyzer for the measurement of kidney function in screening for chronic kidney disease. Clin Chem Lab Med 2010;48:1113-9.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1113-1119
    • Shephard, M.D.1    Peake, M.J.2    Corso, O.3    Shephard, A.4    Mazzachi, B.5    Spaeth, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.