메뉴 건너뛰기




Volumn 6, Issue 6, 2011, Pages

Selective biological response of human pulmonary microvascular endothelial cells and human pulmonary artery smooth muscle cells on cold-plasma-modified polyester vascular prostheses

Author keywords

[No Author keywords available]

Indexed keywords

ADHESION; BIOMECHANICS; CARBOXYLIC ACIDS; COLORIMETRIC ANALYSIS; ETHYLENE; FREE RADICAL POLYMERIZATION; FREE RADICALS; GRAFTING (CHEMICAL); MECHANICAL PROPERTIES; MUSCLE; PLASMA APPLICATIONS; PLASMA POLYMERIZATION; PLASMAS; POLYETHYLENE TEREPHTHALATES; PROSTHETICS; SURFACES; THERMOGRAVIMETRIC ANALYSIS; WEAVING;

EID: 81855219112     PISSN: 17486041     EISSN: 1748605X     Source Type: Journal    
DOI: 10.1088/1748-6041/6/6/065003     Document Type: Article
Times cited : (15)

References (36)
  • 1
    • 0037180771 scopus 로고    scopus 로고
    • Inflammation in atherosclerosis
    • DOI 10.1038/nature01323
    • Libby P 2002 Inflammation in atherosclerosis Nature 420 868-74 (Pubitemid 36019640)
    • (2002) Nature , vol.420 , Issue.6917 , pp. 868-874
    • Libby, P.1
  • 2
    • 0034648768 scopus 로고    scopus 로고
    • Atherosclerosis
    • Lusis A J 2000 Atherosclerosis Nature 407 233-41
    • (2000) Nature , vol.407 , pp. 233-241
    • Lusis, A.J.1
  • 3
  • 4
    • 9444228819 scopus 로고    scopus 로고
    • The nutrition transition: Worldwide obesity dynamics and their determinants
    • DOI 10.1038/sj.ijo.0802804
    • Popkin B M and Gordon-Larsen P 2004 The nutrition transition: worldwide obesity dynamics and their determinants Int. J. Obes. 28 S2-9 (Pubitemid 39564310)
    • (2004) International Journal of Obesity , vol.28 , Issue.SUPPL. 3
    • Popkin, B.M.1    Gordon-Larsen, P.2
  • 5
    • 33846857559 scopus 로고    scopus 로고
    • Heart disease and stroke statistics-2007 update: A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommitee
    • Rosamond W et al. 2007 Heart disease and stroke statistics-2007 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommitee Circulation 115 69-171
    • (2007) Circulation , vol.115 , pp. 69-171
    • Rosamond, W.1
  • 6
    • 34248574088 scopus 로고    scopus 로고
    • Epidemiology of ischemic cardiovascular disease
    • Fontbonne A 2007 Epidemiology of ischemic cardiovascular disease Rev. Med. Int. 28 S9-10
    • (2007) Rev. Med. Int. , vol.28
    • Fontbonne, A.1
  • 7
    • 0027628237 scopus 로고
    • Expanded polytetrafluoroethylene arterial prostheses in humans: Histopathological study of 298 surgically excised grafts
    • DOI 10.1016/0142-9612(93)90067-C
    • Guidoin R, Chakfé N, Maurel S, How T, Batt M, Marois M and Gosselin C 1993 Expanded polytetrafluoroethylene arterial prostheses in humans: histopathological study of 298 surgically excised grafts Biomaterials 14 678-93 (Pubitemid 23233954)
    • (1993) Biomaterials , vol.14 , Issue.9 , pp. 678-693
    • Guidoin, R.1    Chakfe, N.2    Maurel, S.3    How, T.4    Batt, M.5    Marois, M.6    Gosselin, C.7
  • 9
    • 0032555180 scopus 로고    scopus 로고
    • Neointimal tissue response at sites of coronary stenting in humans: Macroscopic, histological, and immunohistochemical analyses
    • Komatsu R, Ueda M, Naruko T, Kojima A and Becker A E 1998 Neointimal tissue response at sites of coronary stenting in humans: macroscopic, histological, and immunohistochemical analyses Circulation 98 224-33 (Pubitemid 28337613)
    • (1998) Circulation , vol.98 , Issue.3 , pp. 224-233
    • Komatsu, R.1    Ueda, M.2    Naruko, T.3    Kojima, A.4    Becker, A.E.5
  • 10
    • 32644453379 scopus 로고    scopus 로고
    • Sirolimus and paclitaxel on polymer-based drug-eluting stents: Similar but different
    • DOI 10.1016/j.jacc.2005.09.047, PII S0735109705027439
    • Wessely R, Schömig A and Kastrati A 2006 Sirolimus and Paclitaxel on polymer-based drug eluting stents J. Am. Coll. Cardiol. 7 708-14 (Pubitemid 43243089)
    • (2006) Journal of the American College of Cardiology , vol.47 , Issue.4 , pp. 708-714
    • Wessely, R.1    Schomig, A.2    Kastrati, A.3
  • 12
    • 33947126928 scopus 로고    scopus 로고
    • Sirolimus-eluting stent showed better one-year outcomes than paclitaxel-eluting stent in a real life setting of coronary intervention in Koreans
    • Suh J W et al. 2007 Sirolimus-eluting stent showed better one-year outcomes than paclitaxel-eluting stent in a real life setting of coronary intervention in Koreans Int. J. Cardiol. 117 31-6
    • (2007) Int. J. Cardiol. , vol.117 , pp. 31-36
    • Suh, J.W.1
  • 13
    • 84903496389 scopus 로고    scopus 로고
    • Maladie Coronaire: La course des stents et des marqueurs
    • Carrié D 2005 Maladie Coronaire: La course des stents et des marqueurs XVes Journées européennes SFC 138 24-8
    • (2005) XVes Journées Européennes SFC , vol.138 , pp. 24-28
    • Carrié, D.1
  • 15
    • 25644459233 scopus 로고    scopus 로고
    • Thrombosis of sirolimus-eluting coronary stent in the postanesthesia care unit
    • DOI 10.1213/01.ANE.0000175821.42010.9F
    • Murphy J T and Fahy B G 2005 Thrombosis of sirolimus-eluting coronary stent in the postanesthesia care unit Anesth. Analg. 101 971-3 (Pubitemid 41383056)
    • (2005) Anesthesia and Analgesia , vol.101 , Issue.4 , pp. 971-973
    • Murphy, J.T.1    Fahy, B.G.2
  • 16
    • 0037778068 scopus 로고    scopus 로고
    • Effect of plasma treatment on the degree of AAm grafting for high-density polyethylene
    • Lu W L, Huang C Y and Roan M L 2003 Effect of plasma treatment on the degree of AAm grafting for high-density polyethylene Surf. Coat. Technol. 172 251-61
    • (2003) Surf. Coat. Technol. , vol.172 , pp. 251-261
    • Lu, W.L.1    Huang, C.Y.2    Roan, M.L.3
  • 17
    • 33847355119 scopus 로고    scopus 로고
    • Functional finishing by using atmospheric pressure plasma: Grafting of PET nonwoven fabric
    • DOI 10.1002/app.25541
    • Shin Y, Son K and Il Yoo D 2007 Functional finishing by using atmospheric pressure plasma: grafting of PET nonwoven fabric J. Appl. Polym. Sci. 103 3655-9 (Pubitemid 46347193)
    • (2007) Journal of Applied Polymer Science , vol.103 , Issue.6 , pp. 3655-3659
    • Shin, Y.1    Son, K.2    Yoo, D.I.3
  • 19
    • 0036132322 scopus 로고    scopus 로고
    • Plasma-induced graft polymerisation of acrylic acid onto poly(ethylene terephthalate) films: Characterisation and human smooth muscle cell growth on grafted films
    • Gupta B, Plummer C, Bisson I, Frey P and Hilborn J 2002 Plasma-induced graft polymerisation of acrylic acid onto poly(ethylene terephthalate) films : characterisation and human smooth muscle cell growth on grafted films Biomaterials 23 863-71
    • (2002) Biomaterials , vol.23 , pp. 863-871
    • Gupta, B.1    Plummer, C.2    Bisson, I.3    Frey, P.4    Hilborn, J.5
  • 20
    • 0000094137 scopus 로고    scopus 로고
    • Surface characterisation and in vitro compatibility of poly(ethylene terephthalate) immobilized with insulin and/or heparin using plasma glow discharge
    • Kim Y J, Kang I K, Huh M W and Yoon S G 2000 Surface characterisation and in vitro compatibility of poly(ethylene terephthalate) immobilized with insulin and/or heparin using plasma glow discharge Biomaterials 21 121-30
    • (2000) Biomaterials , vol.21 , pp. 121-130
    • Kim, Y.J.1    Kang, I.K.2    Huh, M.W.3    Yoon, S.G.4
  • 21
    • 34547741083 scopus 로고    scopus 로고
    • Current strategies towards hemocompatible coatings
    • Werner C, Maitz M.F and Sperling C 2007 Current strategies towards hemocompatible coatings J. Mater. Chem. 17 3376-84
    • (2007) J. Mater. Chem. , vol.17 , pp. 3376-3384
    • Werner, C.1    Maitz, M.F.2    Sperling, C.3
  • 22
    • 0027657061 scopus 로고
    • Introduction of functional groups onto the surface of polyethylene for protein immobilization
    • Sano S, Kato K and Ikada Y 1993 Introduction of functional groups onto the surface of polyethylene for protein immobilization Biomaterials 14 817-22 (Pubitemid 23272147)
    • (1993) Biomaterials , vol.14 , Issue.11 , pp. 817-822
    • Sano, S.1    Kato, K.2    Ikada, Y.3
  • 24
    • 0034547906 scopus 로고    scopus 로고
    • Grafting of cyclodextrins onto polypropylene nonwoven fabrics for the manufacture of reactive filters: II. Characterisation
    • Martel B et al. 2000 Grafting of cyclodextrins onto polypropylene nonwoven fabrics for the manufacture of reactive filters: II. Characterisation J. Appl. Polym. Sci. 78 2166-73
    • (2000) J. Appl. Polym. Sci. , vol.78 , pp. 2166-2173
    • Martel, B.1
  • 26
    • 0036090997 scopus 로고    scopus 로고
    • Graft copolymerization of a mixture of perfluorooctyl-2 ethanol acrylic and stearyl methacrylate onto polyester fibers using benzoyl peroxide as initiator
    • Saihi D, El Achari A, Ghenaim A and Cazé C 2002 Graft copolymerization of a mixture of perfluorooctyl-2 ethanol acrylic and stearyl methacrylate onto polyester fibers using benzoyl peroxide as initiator Polym. Test. 21 607-12
    • (2002) Polym. Test. , vol.21 , pp. 607-612
    • Saihi, D.1    El Achari, A.2    Ghenaim, A.3    Cazé, C.4
  • 28
    • 0033856957 scopus 로고    scopus 로고
    • Investigation of the Alamar Blue (resazurin) fluorescent dye for the assessment of mammalian cell toxicity
    • O'Brien J, Wilson I, Orton T and Pognan F 2000 Investigation of the Alamar Blue (resazurin) fluorescent dye for the assessment of mammalian cell toxicity Eur. J. Biochem. 267 5421-26
    • (2000) Eur. J. Biochem. , vol.267 , pp. 5421-5426
    • O'Brien, J.1    Wilson, I.2    Orton, T.3    Pognan, F.4
  • 29
    • 3142606712 scopus 로고    scopus 로고
    • Comparison of alamar blue and MTT assays for high through-put screening
    • DOI 10.1016/j.tiv.2004.03.012, PII S0887233304000633
    • Hamid R, Rotshteyn Y, Rabadi L, Parikh R and Bullock P 2004 Comparison of alamar blue and MTT assays for high through-put screening Toxicology In Vitro 18 703-10 (Pubitemid 38900879)
    • (2004) Toxicology in Vitro , vol.18 , Issue.5 , pp. 703-710
    • Hamid, R.1    Rotshteyn, Y.2    Rabadi, L.3    Parikh, R.4    Bullock, P.5
  • 30
    • 41549154271 scopus 로고    scopus 로고
    • Biological behaviour of an endothelial cell line (HPMEC) on vascular prostheses grafted withhydroxylpropylbeta-cyclodextrine (HPâ-CD) and hydroxypropylgamma-cyclodextrine (HPã -CD)
    • Blanchemain N et al. 2008 Biological behaviour of an endothelial cell line (HPMEC) on vascular prostheses grafted withhydroxylpropylbeta-cyclodextrine (HPâ-CD) and hydroxypropylgamma-cyclodextrine (HPã -CD) J. Mater. Sci., Mater. Med. 19 2515-23
    • (2008) J. Mater. Sci., Mater. Med. , vol.19 , pp. 2515-2523
    • Blanchemain, N.1
  • 32
    • 0032531290 scopus 로고    scopus 로고
    • Hemocompatibility of treated polystyrene substrates: Contact activation, platelet adhesion, and procoagulant activity of adherent platelets
    • DOI 10.1002/(SICI)1097-4636(19980915)41:4<657::AID-JBM18>3.0.CO;2-B
    • Grunkemeier J M, Tsai B W and Horbett T A 1998 Hemocompatibility of treated polystyrene substrates: contact activation, platelet adhesion, and procoagulant activity of adherent platelets J. Biomed. Mater. Res. 41 657-70 (Pubitemid 28355451)
    • (1998) Journal of Biomedical Materials Research , vol.41 , Issue.4 , pp. 657-670
    • Grunkemeier, J.M.1    Tsai, W.B.2    Horbett, T.A.3
  • 33
    • 0029239613 scopus 로고
    • Simple method for platelet counting
    • Tamada Y, Kulik E A and Ikada Y 1995 Simple method for platelet counting Biomaterials 16 259-61
    • (1995) Biomaterials , vol.16 , pp. 259-261
    • Tamada, Y.1    Kulik, E.A.2    Ikada, Y.3
  • 34
    • 0001081219 scopus 로고
    • Graft copolymerisation of acrylamide onto a polyethylene surface pretreated with a glow discharge
    • Suzuki M, Kishida A, Iwata H and Ikada Y 1986 Graft copolymerisation of acrylamide onto a polyethylene surface pretreated with a glow discharge Macromolecules 19 1804-08
    • (1986) Macromolecules , vol.19 , pp. 1804-1808
    • Suzuki, M.1    Kishida, A.2    Iwata, H.3    Ikada, Y.4
  • 36
    • 33846879001 scopus 로고    scopus 로고
    • Vascular prostheses with controlled release of antibiotics. Part 2. In vitro biological evaluation of vascular prostheses treated by cyclodextrins
    • DOI 10.1016/j.bioeng.2006.05.011, PII S1389034406000463
    • Blanchemain N et al. 2007 Vascular prostheses with controlled release of antibiotics: part 2. in vitro biological evaluation of vascular prostheses treated by cyclodextrins Biomol. Eng. 24 143-8 (Pubitemid 46223548)
    • (2007) Biomolecular Engineering , vol.24 , Issue.1 SPEC. ISS. , pp. 143-148
    • Blanchemain, N.1    Haulon, S.2    Boschin, F.3    Traisnel, M.4    Morcellet, M.5    Martel, B.6    Hildebrand, H.F.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.