메뉴 건너뛰기




Volumn , Issue , 2010, Pages 383-387

Actifit, polyurethane meniscus implant: Basic science

Author keywords

[No Author keywords available]

Indexed keywords


EID: 81855192571     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/978-3-642-02450-4_48     Document Type: Chapter
Times cited : (19)

References (40)
  • 2
    • 0025661650 scopus 로고
    • Use of biodegradable polymer implants in meniscus reconstruction: 2) Biological evaluation of porous biodegradable implants in menisci
    • Elema H, De Groot JH, Nijenhuis AJ, Pennings AJ, Veth RPH, Klompmaker J, Jansen HWB (1990) Use of biodegradable polymer implants in meniscus reconstruction: 2) Biological evaluation of porous biodegradable implants in menisci. Coll Polym Sci 268:1082-1088
    • (1990) Coll Polym Sci , vol.268 , pp. 1082-1088
    • Elema, H.1    De Groot, J.H.2    Nijenhuis, A.J.3    Pennings, A.J.4    Veth, R.P.H.5    Klompmaker, J.6    Jansen, H.W.B.7
  • 3
    • 0025599603 scopus 로고
    • Use of biodegradable polymer implants in meniscus reconstruction. 1) Preparation of porous biodegradable polyurethanes for the reconstruction of the meniscus
    • De Groot JH, Nijenhuis AJ, Bruin P, Pennings AJ, Veth RPH, Klompmaker J, Jansen HWB (1990) Use of biodegradable polymer implants in meniscus reconstruction. 1) Preparation of porous biodegradable polyurethanes for the reconstruction of the meniscus. Coll Polym Sci 268:1073-1081
    • (1990) Coll Polym Sci , vol.268 , pp. 1073-1081
    • De Groot, J.H.1    Nijenhuis, A.J.2    Bruin, P.3    Pennings, A.J.4    Veth, R.P.H.5    Klompmaker, J.6    Jansen, H.W.B.7
  • 6
    • 0031281616 scopus 로고    scopus 로고
    • A novel method for fabrication biodegradable scaffolds with high compression moduli
    • De Groot JH, Kuiper HW, Pennings AJ (1997) A novel method for fabrication biodegradable scaffolds with high compression moduli. J Mater Sci Mat Med 8:703
    • (1997) J Mater Sci Mat Med , vol.8 , pp. 703
    • De Groot, J.H.1    Kuiper, H.W.2    Pennings, A.J.3
  • 8
    • 1542493342 scopus 로고    scopus 로고
    • On the role of aminolysis and transesterification in the synthesis of e-caprolactone and L-lactide based polyurethanes
    • De Groot JH, Spaans CJ, Dekens FG, Pennings AJ (1998) On the role of aminolysis and transesterification in the synthesis of e-caprolactone and L-lactide based polyurethanes. Polym Bul 41:299-306
    • (1998) Polym Bul , vol.41 , pp. 299-306
    • De Groot, J.H.1    Spaans, C.J.2    Dekens, F.G.3    Pennings, A.J.4
  • 11
    • 15944400700 scopus 로고    scopus 로고
    • Uncatalyzed syn thesis thermal and mechanical properties of polyurethanes based on poly(epsilon-caprolactone) and 1, 4-butane diisocyanate with uniform hard segment
    • Heijkants RG, Van Calck RV, Van Tienen TG, De Groot JH, Buma P, Pennings AJ, Veth RP, Schouten AJ (2005) Uncatalyzed synthesis, thermal and mechanical properties of polyurethanes based on poly(epsilon-caprolactone) and 1, 4-butane diisocyanate with uniform hard segment. Biomaterials 26:4219-4228
    • (2005) Biomaterials , vol.26 , pp. 4219-4228
    • Heijkants, R.G.1    Van Calck, R.V.2    Van Tienen, T.G.3    De Groot, J.H.4    Buma, P.5    Pennings, A.J.6    Veth, R.P.7    Schouten, A.J.8
  • 16
    • 0026646776 scopus 로고
    • Porous polymer implants for repair of full-Thickness defects of articular cartilage: An experimental study in the dog
    • Klompmaker J, Jansen HWB, Veth RPH, De Groot JH, Nijenhuis HK, Pennings AJ (1992) Porous polymer implants for repair of full-Thickness defects of articular cartilage: An experimental study in the dog. Biomaterials 13:625-634
    • (1992) Biomaterials , vol.13 , pp. 625-634
    • Klompmaker, J.1    Jansen, H.W.B.2    Veth, R.P.H.3    De Groot, J.H.4    Nijenhuis, H.K.5    Pennings, A.J.6
  • 17
    • 0027197698 scopus 로고
    • Porous implants for the knee joint meiscus reconstruction: A preliminary study on the role of pore sizes in ingrowth and differentiation of fibrocartilage
    • Klompmaker J, Jansen HWB, Veth RPH, Nielsen HKL, De Groot JH, Pennings AJ (1994) Porous implants for the knee joint meiscus reconstruction: A preliminary study on the role of pore sizes in ingrowth and differentiation of fibrocartilage. Clin Mater 14:1-11
    • (1994) Clin Mater , vol.14 , pp. 1-11
    • Klompmaker, J.1    Jansen, H.W.B.2    Veth, R.P.H.3    Nielsen, H.K.L.4    De Groot, J.H.5    Pennings, A.J.6
  • 24
    • 44149089078 scopus 로고    scopus 로고
    • In vivo resorption of a biodegradable polyurethane foam, based on 1,4-butanediisocyanate: A three-year subcutaneous implantation study
    • Minnen B van, Leeuwen MB van, Kors G, Zuidema J, Kooten TG van, Bos RR (2008) In vivo resorption of a biodegradable polyurethane foam, based on 1,4-butanediisocyanate: A three-year subcutaneous implantation study. J Biomed Mater Res A 85:972-982
    • (2008) J Biomed Mater Res A , vol.85 , pp. 972-982
    • Minnen, B.1    Van Leeuwen, M.B.2    Van Kors, G.3    Zuidema, J.4    Kooten, T.G.5    Van Bos, R.R.6
  • 27
    • 0000555103 scopus 로고    scopus 로고
    • High molecular weight polyurethanes and a polyurethane urea based on 1, 4-butanediisocyanate
    • Spaans CJ, De Groot JH, Dekens FG, Pennings AJ (1998) High molecular weight polyurethanes and a polyurethane urea based on 1, 4-butanediisocyanate. Polymer Bull 41: 131-138
    • (1998) Polymer Bull , vol.41 , pp. 131-138
    • Spaans, C.J.1    De Groot, J.H.2    Dekens, F.G.3    Pennings, A.J.4
  • 28
    • 0032423485 scopus 로고    scopus 로고
    • A new biomedical polyurethane with a high modulus based on 1, 4-butanediisocyanate
    • Spaans CJ, Belgraver VW, De Groot JH, Pennings AJ (1998) A new biomedical polyurethane with a high modulus based on 1, 4-butanediisocyanate. J Mat Sci Mat Med 9:675-678
    • (1998) J Mat Sci Mat Med , vol.9 , pp. 675-678
    • Spaans, C.J.1    Belgraver, V.W.2    De Groot, J.H.3    Pennings, A.J.4
  • 29
    • 0032648798 scopus 로고    scopus 로고
    • Development of new polyurethanes for repair and replacement of the knee joint meniscus
    • Spaans CJ, De Groot JH, Dekens FG, Veth RPH, Pennings AJ (1999) Development of new polyurethanes for repair and replacement of the knee joint meniscus. Polym Prep 40: 589-590
    • (1999) Polym Prep , vol.40 , pp. 589-590
    • Spaans, C.J.1    De Groot, J.H.2    Dekens, F.G.3    Veth, R.P.H.4    Pennings, A.J.5
  • 30
    • 0034580478 scopus 로고    scopus 로고
    • Solvent-free fabrication of microporous polyurethane amide and polyurethane urea scaffolds for repair and replacement of the knee joint meniscus
    • Spaans CJ, Belgraver VW, Rienstra OR, Veth RPH, De Groot JH, Pennings AJ (2000) Solvent-free fabrication of microporous polyurethane amide and polyurethane urea scaffolds for repair and replacement of the knee joint meniscus. Biomaterials 21:2453-2460
    • (2000) Biomaterials , vol.21 , pp. 2453-2460
    • Spaans, C.J.1    Belgraver, V.W.2    Rienstra, O.R.3    Veth, R.P.H.4    De Groot, J.H.5    Pennings, A.J.6
  • 32
    • 0037089639 scopus 로고    scopus 로고
    • Tissue ingrowth and degradation of two biodegradable porous polymers with different porosities and pore sizes
    • van Tienen TG, Heijkants RG, Buma P, De Groot JH, Pennings AJ, Veth RP (2002) Tissue ingrowth and degradation of two biodegradable porous polymers with different porosities and pore sizes. Biomaterials 23:1731-1738
    • (2002) Biomaterials , vol.23 , pp. 1731-1738
    • Van Tienen, T.G.1    Heijkants, R.G.2    Buma, P.3    De Groot, J.H.4    Pennings, A.J.5    Veth, R.P.6
  • 37
    • 84892048735 scopus 로고    scopus 로고
    • Verdonk R on behalf of the Actifit Study Group. Clinical efficacy and safety of a resorbable meniscus scaffold for the treatment of partial meniscal tear or meniscal loss. International Meeting on Early Intervention for Knee Arthritis
    • Feb
    • Verdonk P, Verdonk R on behalf of the Actifit Study Group. Clinical efficacy and safety of a resorbable meniscus scaffold for the treatment of partial meniscal tear or meniscal loss. International Meeting on Early Intervention for Knee Arthritis, Maastricht, 4-6 Feb 2009
    • (2009) Maastricht , pp. 4-6
    • Verdonk, P.1
  • 39
    • 52149104452 scopus 로고    scopus 로고
    • Effect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant: A 2-year follow-up study in dogs
    • Welsing RT, Van Tienen TG, Ramrattan N, Heijkants R, Schouten AJ, Veth RP, Buma P (2008) Effect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant: A 2-year follow-up study in dogs. Am J Sports Med 36:1978-1989
    • (2008) Am J Sports Med , vol.36 , pp. 1978-1989
    • Welsing, R.T.1    Van Tienen, T.G.2    Ramrattan, N.3    Heijkants, R.4    Schouten, A.J.5    Veth, R.P.6    Buma, P.7
  • 40
    • 79954504277 scopus 로고    scopus 로고
    • In vitro degradation of a biodegradable polyurethane foam, based on 1,4-butanediisocyanate: A three-year study at physiological and elevated temperature
    • Zuidema J, Van Minnen B, Span MM, Hissink CE, Van Kooten TG, Bos RR (2008) In vitro degradation of a biodegradable polyurethane foam, based on 1,4-butanediisocyanate: A three-year study at physiological and elevated temperature. J Biomed Mater Res A 90:920-30
    • (2008) J Biomed Mater Res A , vol.90 , pp. 920-930
    • Zuidema, J.1    Van Minnen, B.2    Span, M.M.3    Hissink, C.E.4    Van Kooten, T.G.5    Bos, R.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.