메뉴 건너뛰기




Volumn 1, Issue 1, 2012, Pages

Echocardiographic assessment of preload responsiveness in critically Ill patients

Author keywords

[No Author keywords available]

Indexed keywords

CENTRAL VENOUS PRESSURE; CORONARY ARTERY BLOOD FLOW; CRITICALLY ILL PATIENT; DOPPLER ECHOCARDIOGRAPHY; ECHOCARDIOGRAPHY; FLUID RESUSCITATION; HEART LEFT ATRIUM PRESSURE; HEART LEFT VENTRICLE FUNCTION; HEART OUTPUT MEASUREMENT; HEART PERFORMANCE; HEART PRELOAD; HEART STROKE VOLUME; HUMAN; HYPOVOLEMIA; INTENSIVE CARE UNIT; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; PULMONARY ARTERY OCCLUSION PRESSURE; REVIEW; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; VENTILATED PATIENT;

EID: 81555203154     PISSN: None     EISSN: 20900597     Source Type: Journal    
DOI: 10.1155/2012/819696     Document Type: Review
Times cited : (65)

References (30)
  • 2
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • Marik P. E., Cavallazzi R., Vasu T., Hirani A., Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature Critical Care Medicine 2009 37 9 2642 2647
    • (2009) Critical Care Medicine , vol.37 , Issue.9 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 3
    • 0036278240 scopus 로고    scopus 로고
    • Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema
    • DOI 10.1007/s00134-002-1286-6
    • Boussat S., Jacques T., Levy B., Laurent E., Gache A., Capellier G., Neidhardt A., Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema Intensive Care Medicine 2002 28 6 712 718 (Pubitemid 34639483)
    • (2002) Intensive Care Medicine , vol.28 , Issue.6 , pp. 712-718
    • Boussat, S.1    Jacques, T.2    Levy, B.3    Laurent, E.4    Gache, A.5    Capellier, G.6    Neidhardt, A.7
  • 4
    • 78650415602 scopus 로고    scopus 로고
    • Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test
    • Benomar B., Ouattara A., Estagnasie P., Brusset A., Squara P., Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test Intensive Care Medicine 2010 36 11 1875 1881
    • (2010) Intensive Care Medicine , vol.36 , Issue.11 , pp. 1875-1881
    • Benomar, B.1    Ouattara, A.2    Estagnasie, P.3    Brusset, A.4    Squara, P.5
  • 8
    • 79251546295 scopus 로고    scopus 로고
    • Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality
    • Boyd J. H., Forbes J., Nakada T. A., Walley K. R., Russell J. A., Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality Critical Care Medicine 2011 39 2 259 265
    • (2011) Critical Care Medicine , vol.39 , Issue.2 , pp. 259-265
    • Boyd, J.H.1    Forbes, J.2    Nakada, T.A.3    Walley, K.R.4    Russell, J.A.5
  • 10
    • 58349095419 scopus 로고    scopus 로고
    • Review of a large clinical series: Association of cumulative fluid balance on outcome in acute lung injury: A retrospective review of the ARDSnet tidal volume study cohort
    • Rosenberg A. L., Dechert R. E., Park P. K., Bartlett R. H., Review of a large clinical series: association of cumulative fluid balance on outcome in acute lung injury: a retrospective review of the ARDSnet tidal volume study cohort Journal of Intensive Care Medicine 2009 24 1 35 46
    • (2009) Journal of Intensive Care Medicine , vol.24 , Issue.1 , pp. 35-46
    • Rosenberg, A.L.1    Dechert, R.E.2    Park, P.K.3    Bartlett, R.H.4
  • 12
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness?
    • DOI 10.1378/chest.07-2331
    • Marik P. E., Baram M., Vahid B., Does central venous pressure predict fluid responsiveness? Chest 2008 134 1 172 178 (Pubitemid 352008780)
    • (2008) Chest , vol.134 , Issue.1 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 13
    • 34547901343 scopus 로고    scopus 로고
    • A survey of Canadian intensivists' resuscitation practices in early septic shock
    • McIntyre L. A., Hébert P. C., Fergusson D., Cook D. J., Aziz A., A survey of Canadian intensivists' resuscitation practices in early septic shock Critical Care 2007 11, article R74
    • (2007) Critical Care , vol.1174
    • McIntyre, L.A.1    Hébert, P.C.2    Fergusson, D.3    Cook, D.J.4    Aziz, A.5
  • 15
    • 12144287425 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
    • DOI 10.1097/01.CCM.0000114996.68110.C9
    • Kumar A., Anel R., Bunnell E., Habet K., Zanotti S., Marshall S., Neumann A., Ali A., Cheang M., Kavinsky C., Parrillo J. E., Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects Critical Care Medicine 2004 32 3 691 699 (Pubitemid 38340065)
    • (2004) Critical Care Medicine , vol.32 , Issue.3 , pp. 691-699
    • Kumar, A.1    Anel, R.2    Bunnell, E.3    Habet, K.4    Zanotti, S.5    Marshall, S.6    Neumann, A.7    Ali, A.8    Cheang, M.9    Kavinsky, C.10    Parrillo, J.E.11
  • 16
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • DOI 10.1378/chest.121.6.2000
    • Michard F., Teboul J. L., Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence Chest 2002 121 6 2000 2008 (Pubitemid 34634425)
    • (2002) Chest , vol.121 , Issue.6 , pp. 2000-2008
    • Michard, F.1    Teboul, J.-L.2
  • 17
    • 29144442013 scopus 로고    scopus 로고
    • Fluid responsiveness in spontaneously breathing patients: A review of indexes used in intensive care
    • DOI 10.1097/01.CCM.0000189942.24113.65
    • Coudray A., Romand J. A., Treggiari M., Bendjelid K., Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care Critical Care Medicine 2005 33 12 2757 2762 (Pubitemid 41816408)
    • (2005) Critical Care Medicine , vol.33 , Issue.12 , pp. 2757-2762
    • Coudray, A.1    Romand, J.-A.2    Treggiari, M.3    Bendjelid, K.4
  • 18
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • DOI 10.1007/s00134-004-2233-5
    • Feissel M., Michard F., Faller J. P., Teboul J. L., The respiratory variation in inferior vena cava diameter as a guide to fluid therapy Intensive Care Medicine 2004 30 9 1834 1837 (Pubitemid 39297190)
    • (2004) Intensive Care Medicine , vol.30 , Issue.9 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.-P.3    Teboul, J.-L.4
  • 19
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • DOI 10.1097/00000542-199812000-00007
    • Tavernier B., Makhotine O., Lebuffe G., Dupont J., Scherpereel P., Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension Anesthesiology 1998 89 6 1313 1321 (Pubitemid 29001568)
    • (1998) Anesthesiology , vol.89 , Issue.6 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3    Dupont, J.4    Scherpereel, P.5
  • 20
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • DOI 10.1378/chest.119.3.867
    • Feissel M., Michard F., Mangin I., Ruyer O., Faller J. P., Teboul J. L., Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock Chest 2001 119 3 867 873 (Pubitemid 32197661)
    • (2001) Chest , vol.119 , Issue.3 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.-P.5    Teboul, J.-L.6
  • 21
    • 69349089330 scopus 로고    scopus 로고
    • Stroke volume variations and fluid responsiveness. A systematic review of literature
    • Marik P. E., Cavallazzi R., Vasu T., Stroke volume variations and fluid responsiveness. A systematic review of literature Critical Care Medicine 2009 37 2642 2647
    • (2009) Critical Care Medicine , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3
  • 22
    • 33847413174 scopus 로고    scopus 로고
    • Is there a safe plateau pressure in ARDS? The right heart only knows
    • DOI 10.1007/s00134-007-0552-z
    • Jardin F., Vieillard-Baron A., Is there a safe plateau pressure in ARDS? The right heart only knows Intensive Care Medicine 2007 33 3 444 447 (Pubitemid 46333856)
    • (2007) Intensive Care Medicine , vol.33 , Issue.3 , pp. 444-447
    • Jardin, F.1    Vieillard-Baron, A.2
  • 24
    • 33846871748 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients
    • Cannesson M., Slieker J., Desebbe O., Farhat F., Bastien O., Lehot J. J., Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients Critical Care 2006 10, article R171
    • (2006) Critical Care , pp. 10171
    • Cannesson, M.1    Slieker, J.2    Desebbe, O.3    Farhat, F.4    Bastien, O.5    Lehot, J.J.6
  • 25
    • 33748528579 scopus 로고    scopus 로고
    • Echocardiographic measurement of fluid responsiveness
    • DOI 10.1097/01.ccx.0000224870.24324.cc, PII 0007519820060600000013
    • Charron C., Caille V., Jardin F., Vieillard-Baron A., Echocardiographic measurement of fluid responsiveness Current Opinion in Critical Care 2006 12 3 249 254 (Pubitemid 44365954)
    • (2006) Current Opinion in Critical Care , vol.12 , Issue.3 , pp. 249-254
    • Charron, C.1    Caille, V.2    Jardin, F.3    Vieillard-Baron, A.4
  • 28
    • 34447117107 scopus 로고    scopus 로고
    • Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity
    • DOI 10.1007/s00134-007-0646-7
    • Lamia B., Ochagavia A., Monnet X., Chemla D., Richard C., Teboul J. L., Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity Intensive Care Medicine 2007 33 7 1125 1132 (Pubitemid 47036887)
    • (2007) Intensive Care Medicine , vol.33 , Issue.7 , pp. 1125-1132
    • Lamia, B.1    Ochagavia, A.2    Monnet, X.3    Chemla, D.4    Richard, C.5    Teboul, J.-L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.