메뉴 건너뛰기




Volumn 160, Issue 1, 2011, Pages 1444-1449

A novel biosensor for reduced l-glutathione based on cobalt phthalocyaninetetrasulfonate-intercalated layered double hydroxide modified glassy carbon electrodes

Author keywords

Biosensor; Cobalt phthalocyaninetetrasulfonate; Intercalated structure; Layered double hydroxide; Reduced l glutathione

Indexed keywords

BIOELECTRONIC DEVICE; BIOLOGICAL MOLECULE; COBALT PHTHALOCYANINE; COBALT PHTHALOCYANINETETRASULFONATE; ELECTRO-CATALYTIC OXIDATION; ELECTROCATALYTIC ACTIVITY AND STABILITY; GC ELECTRODE; GLASSY CARBON ELECTRODES; IN-FIELD; INTERCALATED STRUCTURES; LAYERED DOUBLE HYDROXIDES; LOW DETECTION LIMIT; MODIFIED ELECTRODES; MODIFIED GLASSY CARBON ELECTRODE; OUTER SURFACE; PHYSIOLOGICAL PH; POTENTIAL APPLICATIONS; REDUCED L-GLUTATHIONE; WIDE-LINEAR RANGE; ZN-AL LAYERED DOUBLE HYDROXIDES;

EID: 81155137692     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.10.011     Document Type: Article
Times cited : (45)

References (42)
  • 1
    • 0021308996 scopus 로고
    • Acetaminophen hepatotoxicity
    • M. Black Acetaminophen hepatotoxicity Annu. Rev. Med. 35 1984 577 593
    • (1984) Annu. Rev. Med. , vol.35 , pp. 577-593
    • Black, M.1
  • 2
    • 0033981389 scopus 로고    scopus 로고
    • Free radicals antioxidant enzymes and lipid peroxidation in different types of leukemias
    • G.S. Devi, M.H. Prasad, I. Saraswathi, D. Raghu, D.N. Rao, and P.P. Reddy Free radicals antioxidant enzymes and lipid peroxidation in different types of leukemias Clin. Chim. Acta 293 2000 53 62
    • (2000) Clin. Chim. Acta , vol.293 , pp. 53-62
    • Devi, G.S.1    Prasad, M.H.2    Saraswathi, I.3    Raghu, D.4    Rao, D.N.5    Reddy, P.P.6
  • 3
    • 0030659154 scopus 로고    scopus 로고
    • Determination of glutathione, glutathione reductase, glutathione peroxidase and glutathione S-transferase levels in human lung cancer tissues
    • N. Saydam, A. Kirb, Ö. Demir, E. Hazan, Ö. Oto, O. Saydam, and G. Güner Determination of glutathione, glutathione reductase, glutathione peroxidase and glutathione S-transferase levels in human lung cancer tissues Cancer Lett. 119 1997 13 19
    • (1997) Cancer Lett. , vol.119 , pp. 13-19
    • Saydam, N.1    Kirb, A.2    Demir, Ö.3    Hazan, E.4    Oto, Ö.5    Saydam, O.6    Güner, G.7
  • 4
    • 70349185896 scopus 로고    scopus 로고
    • Determination of glutathione and glutathione disulfide in biological samples: An in-depth review
    • P. Monostori, G. Wittmann, E. Karg, and S. Túri Determination of glutathione and glutathione disulfide in biological samples: an in-depth review J. Chromatogr. B 877 2009 3331 3346
    • (2009) J. Chromatogr. B , vol.877 , pp. 3331-3346
    • Monostori, P.1    Wittmann, G.2    Karg, E.3    Túri, S.4
  • 5
    • 80052322199 scopus 로고    scopus 로고
    • A colorimetric and ratiometric fluorescent probe for quantitative detection of GSH at physiologically relevant levels
    • 10.1016/j.snb.2011.06.062
    • X.D. Zeng, X.L. Zhang, B.C. Zhu, H.Y. Jia, W. Yang, Y.M. Li, and J. Xue A colorimetric and ratiometric fluorescent probe for quantitative detection of GSH at physiologically relevant levels Sens. Actuators B 2011 10.1016/j.snb.2011.06.062
    • (2011) Sens. Actuators B
    • Zeng, X.D.1    Zhang, X.L.2    Zhu, B.C.3    Jia, H.Y.4    Yang, W.5    Li, Y.M.6    Xue, J.7
  • 6
    • 0022024989 scopus 로고
    • Electrocatalytic and analytical response of cobalt phthalocyanine containing carbon paste electrodes toward sulfhydryl compounds
    • M.K. Halbert, and R.P. Baldwin Electrocatalytic and analytical response of cobalt phthalocyanine containing carbon paste electrodes toward sulfhydryl compounds Anal. Chem. 57 1985 591 595
    • (1985) Anal. Chem. , vol.57 , pp. 591-595
    • Halbert, M.K.1    Baldwin, R.P.2
  • 7
    • 0034733844 scopus 로고    scopus 로고
    • Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide
    • G. Chwatko, and E. Bald Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide Talanta 52 2000 509 515
    • (2000) Talanta , vol.52 , pp. 509-515
    • Chwatko, G.1    Bald, E.2
  • 8
    • 84987505846 scopus 로고
    • The application of chemically modified electrodes in analytical chemistry
    • S.J. Dong, and Y.D. Wang The application of chemically modified electrodes in analytical chemistry Electroanalysis 1 1989 99 106
    • (1989) Electroanalysis , vol.1 , pp. 99-106
    • Dong, S.J.1    Wang, Y.D.2
  • 9
    • 0036738408 scopus 로고    scopus 로고
    • Real-time electrochemical monitoring: Toward green analytical chemistry
    • J. Wang Real-time electrochemical monitoring: toward green analytical chemistry Acc. Chem. Res. 35 2002 811 816
    • (2002) Acc. Chem. Res. , vol.35 , pp. 811-816
    • Wang, J.1
  • 10
    • 7644233486 scopus 로고    scopus 로고
    • Sol-gel-derived ceramic-carbon nanotube nanocomposite electrodes: Tunable electrode dimension and potential electrochemical applications
    • K.P. Gong, M.N. Zhang, Y.M. Yan, L. Su, L.Q. Mao, S.X. Xiong, and Y. Chen Sol-gel-derived ceramic-carbon nanotube nanocomposite electrodes: tunable electrode dimension and potential electrochemical applications Anal. Chem. 76 2004 6500 6505
    • (2004) Anal. Chem. , vol.76 , pp. 6500-6505
    • Gong, K.P.1    Zhang, M.N.2    Yan, Y.M.3    Su, L.4    Mao, L.Q.5    Xiong, S.X.6    Chen, Y.7
  • 11
    • 33645141688 scopus 로고    scopus 로고
    • Electrochemical oxidation of glutathione at well-aligned carbon nanotube array electrode
    • H. Tang, J.H. Chen, L.H. Nie, S.Z. Yao, and Y.F. Kuang Electrochemical oxidation of glutathione at well-aligned carbon nanotube array electrode Electrochim. Acta 51 2006 3046 3051
    • (2006) Electrochim. Acta , vol.51 , pp. 3046-3051
    • Tang, H.1    Chen, J.H.2    Nie, L.H.3    Yao, S.Z.4    Kuang, Y.F.5
  • 12
    • 0034978715 scopus 로고    scopus 로고
    • Development of an amperometric biosensor based on glutathione peroxidase immobilized in a carbodiimide matrix for the analysis of reduced glutathione from serum
    • L. Rover Jr., L.T. Kubota, and N.F. Höehr Development of an amperometric biosensor based on glutathione peroxidase immobilized in a carbodiimide matrix for the analysis of reduced glutathione from serum Clin. Chim. Acta 308 2001 55 67
    • (2001) Clin. Chim. Acta , vol.308 , pp. 55-67
    • Rover, Jr.L.1    Kubota, L.T.2    Höehr, N.F.3
  • 13
    • 0034529358 scopus 로고    scopus 로고
    • Electrochemical detection of thiols with a coenzyme pyrroloquinoline quinone modified electrode
    • T. Inoue, and J.R. Kirchhoff Electrochemical detection of thiols with a coenzyme pyrroloquinoline quinone modified electrode Anal. Chem. 72 2000 5755 5760
    • (2000) Anal. Chem. , vol.72 , pp. 5755-5760
    • Inoue, T.1    Kirchhoff, J.R.2
  • 14
    • 77957969035 scopus 로고    scopus 로고
    • Metallophthalocyanine-based molecular materials as catalysts for electrochemical reactions
    • J.H. Zagal, S. Griveau, J.F. Silva, T. Nyokong, and F. Bedioui Metallophthalocyanine-based molecular materials as catalysts for electrochemical reactions Coord. Chem. Rev. 254 2010 2755 2791
    • (2010) Coord. Chem. Rev. , vol.254 , pp. 2755-2791
    • Zagal, J.H.1    Griveau, S.2    Silva, J.F.3    Nyokong, T.4    Bedioui, F.5
  • 15
    • 34848873110 scopus 로고    scopus 로고
    • Tuning the redox properties of metalloporphyrin- and metallophthalocyanine-based molecular electrodes for the highest electrocatalytic activity in the oxidation of thiols
    • F. Bedioui, S. Griveau, T. Nyokong, A.J. Appleby, C.A. Caro, M. Gulppi, G. Ochoa, and J.H. Zagal Tuning the redox properties of metalloporphyrin- and metallophthalocyanine-based molecular electrodes for the highest electrocatalytic activity in the oxidation of thiols Phys. Chem. Chem. Phys. 9 2007 3383 3396
    • (2007) Phys. Chem. Chem. Phys. , vol.9 , pp. 3383-3396
    • Bedioui, F.1    Griveau, S.2    Nyokong, T.3    Appleby, A.J.4    Caro, C.A.5    Gulppi, M.6    Ochoa, G.7    Zagal, J.H.8
  • 16
    • 0036158943 scopus 로고    scopus 로고
    • Comparative study of electropolymerized cobalt porphyrin and phthalocyanine based films for the electrochemical activation of thiols
    • S. Griveau, V. Albin, T. Pauporté, J.H. Zagal, and F. Bedioui Comparative study of electropolymerized cobalt porphyrin and phthalocyanine based films for the electrochemical activation of thiols J. Mater. Chem. 12 2002 225 232
    • (2002) J. Mater. Chem. , vol.12 , pp. 225-232
    • Griveau, S.1    Albin, V.2    Pauporté, T.3    Zagal, J.H.4    Bedioui, F.5
  • 17
    • 34250329175 scopus 로고    scopus 로고
    • Glassy carbon electrodes modified with single walled carbon nanotubes and cobalt phthalocyanine and nickel tetrasulfonated phthalocyanine: Highly stable new hybrids with enhanced electrocatalytic performances
    • J.F. Silva, S. Griveau, C. Richard, J.H. Zagal, and F. Bedioui Glassy carbon electrodes modified with single walled carbon nanotubes and cobalt phthalocyanine and nickel tetrasulfonated phthalocyanine: highly stable new hybrids with enhanced electrocatalytic performances Electrochem. Commun. 9 2007 1629 1634
    • (2007) Electrochem. Commun. , vol.9 , pp. 1629-1634
    • Silva, J.F.1    Griveau, S.2    Richard, C.3    Zagal, J.H.4    Bedioui, F.5
  • 19
    • 33845681236 scopus 로고    scopus 로고
    • Electrocatalytic activity of cobalt phthalocyanine CoPc adsorbed on a graphite electrode for the oxidation of reduced l-glutathione (GSH) and the reduction of its disulfide (GSSG) at physiological pH
    • N.P. Rodrigues, R. Cofré, J.H. Zagal, and F. Bedioui Electrocatalytic activity of cobalt phthalocyanine CoPc adsorbed on a graphite electrode for the oxidation of reduced l-glutathione (GSH) and the reduction of its disulfide (GSSG) at physiological pH Bioelectrochemistry 70 2007 147 154
    • (2007) Bioelectrochemistry , vol.70 , pp. 147-154
    • Rodrigues, N.P.1    Cofré, R.2    Zagal, J.H.3    Bedioui, F.4
  • 20
    • 10044232555 scopus 로고    scopus 로고
    • A novel glucose biosensor based on the nanoscaled cobalt phthalocyanine-glucose oxidase biocomposite
    • K. Wang, J.J. Xu, and H.Y. Chen A novel glucose biosensor based on the nanoscaled cobalt phthalocyanine-glucose oxidase biocomposite Biosens. Bioelectron. 20 2005 1388 1396
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1388-1396
    • Wang, K.1    Xu, J.J.2    Chen, H.Y.3
  • 21
    • 53049103416 scopus 로고    scopus 로고
    • Non-enzymatic glucose biosensor based on overoxidized polypyrrole nanofiber electrode modified with cobalt(II) phthalocyanine tetrasulfonate
    • L. Özcan, Y. ahin, and H. Türk Non-enzymatic glucose biosensor based on overoxidized polypyrrole nanofiber electrode modified with cobalt(II) phthalocyanine tetrasulfonate Biosens. Bioelectron. 24 2008 512 517
    • (2008) Biosens. Bioelectron. , vol.24 , pp. 512-517
    • Özcan, L.1    Ahin, Y.2    Türk, H.3
  • 22
    • 77955309606 scopus 로고    scopus 로고
    • Determination of epinephrine in urine using multi-walled carbon nanotube modified with cobalt phthalocyanine in a paraffin composite electrode
    • F.C. Moraes, D.L.C. Golinelli, L.H. Mascaro, and S.A.S. Machado Determination of epinephrine in urine using multi-walled carbon nanotube modified with cobalt phthalocyanine in a paraffin composite electrode Sens. Actuators B 148 2010 492 497
    • (2010) Sens. Actuators B , vol.148 , pp. 492-497
    • Moraes, F.C.1    Golinelli, D.L.C.2    Mascaro, L.H.3    MacHado, S.A.S.4
  • 23
    • 0035793195 scopus 로고    scopus 로고
    • Electro-oxidation of 2-mercaptoethanol on adsorbed monomeric and electropolymerized cobalt tetra-aminophthalocyanine films. Effect of film thickness
    • S. Griveau, J. Pavez, J.H. Zagal, and F. Bedioui Electro-oxidation of 2-mercaptoethanol on adsorbed monomeric and electropolymerized cobalt tetra-aminophthalocyanine films. Effect of film thickness J. Electroanal. Chem. 497 2001 75 83
    • (2001) J. Electroanal. Chem. , vol.497 , pp. 75-83
    • Griveau, S.1    Pavez, J.2    Zagal, J.H.3    Bedioui, F.4
  • 24
    • 33645146969 scopus 로고    scopus 로고
    • Dissolved oxygen sensor based on cobalt tetrasulphonated phthalocyanine immobilized in poly-l-lysine film onto glassy carbon electrode
    • R.C.S. Luz, F.S. Damos, A.A. Tanaka, and L.T. Kubota Dissolved oxygen sensor based on cobalt tetrasulphonated phthalocyanine immobilized in poly-l-lysine film onto glassy carbon electrode Sens. Actuators B 114 2006 1019 1027
    • (2006) Sens. Actuators B , vol.114 , pp. 1019-1027
    • Luz, R.C.S.1    Damos, F.S.2    Tanaka, A.A.3    Kubota, L.T.4
  • 25
    • 18244371996 scopus 로고
    • Catalytic oxidation of 2-mercaptoethanol by cobalt(II)-phthalocyanine intercalated in layered double hydroxides
    • V.I. Iliev, A.I. Ileva, and L.D. Dimitrov Catalytic oxidation of 2-mercaptoethanol by cobalt(II)-phthalocyanine intercalated in layered double hydroxides Appl. Catal. A: Gen. 126 1995 333 340
    • (1995) Appl. Catal. A: Gen. , vol.126 , pp. 333-340
    • Iliev, V.I.1    Ileva, A.I.2    Dimitrov, L.D.3
  • 27
    • 49849092645 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalysis based on a film of horseradish peroxidase intercalated into Ni-Al layered double hydroxide nanosheets
    • X. Chen, C.L. Fu, Y. Wang, W.S. Yang, and D.G. Evans Direct electrochemistry and electrocatalysis based on a film of horseradish peroxidase intercalated into Ni-Al layered double hydroxide nanosheets Biosens. Bioelectron. 24 2008 356 361
    • (2008) Biosens. Bioelectron. , vol.24 , pp. 356-361
    • Chen, X.1    Fu, C.L.2    Wang, Y.3    Yang, W.S.4    Evans, D.G.5
  • 28
    • 33746220289 scopus 로고    scopus 로고
    • Specific determination of As(V) by an acid phosphatase-polyphenol oxidase biosensor
    • S. Cosnier, C. Mousty, X.Q. Cui, X.R. Yang, and S.J. Dong Specific determination of As(V) by an acid phosphatase-polyphenol oxidase biosensor Anal. Chem. 78 2006 4985 4989
    • (2006) Anal. Chem. , vol.78 , pp. 4985-4989
    • Cosnier, S.1    Mousty, C.2    Cui, X.Q.3    Yang, X.R.4    Dong, S.J.5
  • 29
    • 58149260241 scopus 로고    scopus 로고
    • Development of a high analytical performance-xanthine biosensor based on layered double hydroxides modified-electrode and investigation of the inhibitory effect by allopurinol
    • D. Shan, Y.N. Wang, M.J. Zhu, H.G. Xue, S. Cosnier, and C.Y. Wang Development of a high analytical performance-xanthine biosensor based on layered double hydroxides modified-electrode and investigation of the inhibitory effect by allopurinol Biosens. Bioelectron. 24 2009 1171 1176
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 1171-1176
    • Shan, D.1    Wang, Y.N.2    Zhu, M.J.3    Xue, H.G.4    Cosnier, S.5    Wang, C.Y.6
  • 30
    • 33846821739 scopus 로고    scopus 로고
    • Laccase immobilization in redox active layered double hydroxides: A reagentless amperometric biosensor
    • C. Mousty, L. Vieille, and S. Cosnier Laccase immobilization in redox active layered double hydroxides: a reagentless amperometric biosensor Biosens. Bioelectron. 22 2007 1733 1738
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 1733-1738
    • Mousty, C.1    Vieille, L.2    Cosnier, S.3
  • 31
    • 33947490614 scopus 로고
    • Complexes derived from strong field ligands. XIX. Magnetic properties of transition metal derivatives of 4,4′,4,4′-tetrasulfophthalocyanine
    • J.H. Weber, and D.H. Busch Complexes derived from strong field ligands. XIX. Magnetic properties of transition metal derivatives of 4,4′,4, 4′-tetrasulfophthalocyanine Inorg. Chem. 4 1965 469 471
    • (1965) Inorg. Chem. , vol.4 , pp. 469-471
    • Weber, J.H.1    Busch, D.H.2
  • 32
    • 0033590480 scopus 로고    scopus 로고
    • A new method of intercalation by anion exchange in layered double hydroxides
    • E.L. Crepaldi, P.C. Pavan, and J.B. Valim A new method of intercalation by anion exchange in layered double hydroxides Chem. Commun. 999 1999 155 156
    • (1999) Chem. Commun. , vol.999 , pp. 155-156
    • Crepaldi, E.L.1    Pavan, P.C.2    Valim, J.B.3
  • 33
    • 0001475589 scopus 로고
    • Interactions of water-soluble porphyrins and metalloporphyrins with smectite clay surfaces
    • K.A. Carrado, and R.E. Winans Interactions of water-soluble porphyrins and metalloporphyrins with smectite clay surfaces Chem. Mater. 2 1990 328 335
    • (1990) Chem. Mater. , vol.2 , pp. 328-335
    • Carrado, K.A.1    Winans, R.E.2
  • 35
    • 0035973877 scopus 로고    scopus 로고
    • Reactivity of electrodes modified with substituted metallophthalocyanines. Correlations with redox potentials, Hammett parameters and donor-acceptor intermolecular hardness
    • G.I. Cárdenas-Jirón, M.A. Gulppi, C.A. Caro, R.D. Río, M. Páez, and J.H. Zagal Reactivity of electrodes modified with substituted metallophthalocyanines. Correlations with redox potentials, Hammett parameters and donor-acceptor intermolecular hardness Electrochim. Acta 46 2001 3227 3235
    • (2001) Electrochim. Acta , vol.46 , pp. 3227-3235
    • Cárdenas-Jirón, G.I.1    Gulppi, M.A.2    Caro, C.A.3    Río, R.D.4    Páez, M.5    Zagal, J.H.6
  • 37
    • 44749088259 scopus 로고    scopus 로고
    • Electrocatalytic activity of 4-nitrophthalonitrile-modified electrode for the l-glutathione detection
    • P.R. Lima, W.J.R. Santos, A.B. Oliveira, M.O.F. Goulart, and L.T. Kubota Electrocatalytic activity of 4-nitrophthalonitrile-modified electrode for the l-glutathione detection J. Pharm. Biomed. Anal. 47 2008 758 764
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 758-764
    • Lima, P.R.1    Santos, W.J.R.2    Oliveira, A.B.3    Goulart, M.O.F.4    Kubota, L.T.5
  • 38
    • 79954584850 scopus 로고    scopus 로고
    • Electrochemical glutathione sensor based on electrochemically deposited poly-m-aminophenol
    • Y. Oztekin, A. Ramanaviciene, and A. Ramanavicius Electrochemical glutathione sensor based on electrochemically deposited poly-m-aminophenol Electroanalysis 23 2011 701 709
    • (2011) Electroanalysis , vol.23 , pp. 701-709
    • Oztekin, Y.1    Ramanaviciene, A.2    Ramanavicius, A.3
  • 39
    • 50149097724 scopus 로고    scopus 로고
    • Electrocatalysis of reduced l-glutathione oxidation by iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) adsorbed on multi-walled carbon nanotubes
    • R.C.S. Luz, F.S. Damos, A.A. Tanaka, L.T. Kubota, and Y. Gushikem Electrocatalysis of reduced l-glutathione oxidation by iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) adsorbed on multi-walled carbon nanotubes Talanta 76 2008 1097 1104
    • (2008) Talanta , vol.76 , pp. 1097-1104
    • Luz, R.C.S.1    Damos, F.S.2    Tanaka, A.A.3    Kubota, L.T.4    Gushikem, Y.5
  • 40
    • 77956434461 scopus 로고    scopus 로고
    • The electrocatalytic activity of a supramolecular assembly of CoTsPc/FeT4MPyP on multi-walled carbon nanotubes towards l-glutathione, and its determination in human erythrocytes
    • R.C.S. Luz, C.M. Maroneze, A.A. Tanaka, L.T. Kubota, Y. Gushikem, and F.S. Damos The electrocatalytic activity of a supramolecular assembly of CoTsPc/FeT4MPyP on multi-walled carbon nanotubes towards l-glutathione, and its determination in human erythrocytes Microchim. Acta 171 2010 169 178
    • (2010) Microchim. Acta , vol.171 , pp. 169-178
    • Luz, R.C.S.1    Maroneze, C.M.2    Tanaka, A.A.3    Kubota, L.T.4    Gushikem, Y.5    Damos, F.S.6
  • 41
    • 33746716194 scopus 로고    scopus 로고
    • Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ
    • P. Calvo-Marzal, K.Y. Chumbimuni-Torres, N.F. Höehr, and L.T. Kubota Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ Clin. Chim. Acta 371 2006 152 158
    • (2006) Clin. Chim. Acta , vol.371 , pp. 152-158
    • Calvo-Marzal, P.1    Chumbimuni-Torres, K.Y.2    Höehr, N.F.3    Kubota, L.T.4
  • 42
    • 0032999632 scopus 로고    scopus 로고
    • Potentiometric biosensor for l-ascorbic acid based on ascorbate oxidase of natural source immobilized on ethylene-vinylacetate membrane
    • J.C.B. Fernandes, L.T. Kubota, and G.O. Neto Potentiometric biosensor for l-ascorbic acid based on ascorbate oxidase of natural source immobilized on ethylene-vinylacetate membrane Anal. Chim. Acta 385 1999 3 12
    • (1999) Anal. Chim. Acta , vol.385 , pp. 3-12
    • Fernandes, J.C.B.1    Kubota, L.T.2    Neto, G.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.