메뉴 건너뛰기




Volumn 10, Issue 2, 2011, Pages

Fabrication of a needle-type pH sensor by selective electrodeposition

Author keywords

Electrochemical sensor; Electrodeposition; MEMS; Microelectrodes; PH sensor

Indexed keywords

ELECTRODEPOSITION; FABRICATION; IONS; IRIDIUM; IRIDIUM COMPOUNDS; MICROELECTRODES; NEEDLES; OXIDE FILMS; PH; SENSORS;

EID: 80455163261     PISSN: 19325150     EISSN: 19325134     Source Type: Journal    
DOI: 10.1117/1.3580751     Document Type: Article
Times cited : (15)

References (12)
  • 1
    • 0028533398 scopus 로고
    • Density, porosity, and pore structure of biofilms
    • T. C. Zhang and P. L. Bishop, "Density, porosity, and pore structure of biofilms," Water Res. 28, 2267-2277 (1994).
    • (1994) Water Res. , vol.28 , pp. 2267-2277
    • Zhang, T.C.1    Bishop, P.L.2
  • 2
    • 33645089921 scopus 로고    scopus 로고
    • Probing cellular chemistry in biological systems with microelectrodes
    • R. M. Wightman, "Probing cellular chemistry in biological systems with microelectrodes," Science 311, 1570-1574 (2006).
    • (2006) Science , vol.311 , pp. 1570-1574
    • Wightman, R.M.1
  • 3
    • 0036713197 scopus 로고    scopus 로고
    • Ultramicroelectrodes: Design, fabrication, and characterization
    • C. G. Zoski, "Ultramicroelectrodes: Design, fabrication, and characterization," Electroanalysis 14, 1041-1051 (2002).
    • (2002) Electroanalysis , vol.14 , pp. 1041-1051
    • Zoski, C.G.1
  • 5
    • 36249022063 scopus 로고    scopus 로고
    • MEMS needle-type sensor array for in situ measurements of dissolved oxygen and redox potential
    • DOI 10.1021/es070969o
    • J.-H. Lee, Y. Seo, T.-S. Lim, P. L. Bishop, and I. Papautsky, "MEMS needle-type sensor array for in situ measurements of dissolved oxygen and redox potential," Environ. Sci. Technol. 41, 7857-7863 (2007). (Pubitemid 350133329)
    • (2007) Environmental Science and Technology , vol.41 , Issue.22 , pp. 7857-7863
    • Lee, J.-H.1    Seo, Y.2    Lim, T.-S.3    Bishop, P.L.4    Papautsky, I.5
  • 6
    • 35748934480 scopus 로고    scopus 로고
    • Needle-type dissolved oxygen microelectrode array sensors for in situ measurements
    • DOI 10.1016/j.snb.2007.06.008, PII S0925400507004030
    • J.-H. Lee, T.-S. Lim, Y. Seo, P. L. Bishop, and I. Papautsky, "Needletype dissolved oxygen microelectrode array sensors for in situ measurements," Sens. Actuators B 128, 179-185 (2007). (Pubitemid 350051806)
    • (2007) Sensors and Actuators, B: Chemical , vol.128 , Issue.1 , pp. 179-185
    • Lee, J.-H.1    Lim, T.-S.2    Seo, Y.3    Bishop, P.L.4    Papautsky, I.5
  • 7
    • 67949110964 scopus 로고    scopus 로고
    • Effect of recess dimensions on performance of the needle-type dissolved oxygen microelectrode sensor
    • T.-S. Lim, J.-H. Lee, and I. Papautsky, "Effect of recess dimensions on performance of the needle-type dissolved oxygen microelectrode sensor," Sens. Actuators B 141, 50-57 (2009).
    • (2009) Sens. Actuators B , vol.141 , pp. 50-57
    • Lim, T.-S.1    Lee, J.-H.2    Papautsky, I.3
  • 8
    • 0032400890 scopus 로고    scopus 로고
    • Electrodeposited iridium oxide pH electrode formeasurement of extracellular myocardial acidosis during acute ischemia
    • S. A. M. Marzouk, S. Ufer, R. P. Buck, T. A. Johnson, L. A. Dunlap, and W. E. Cascio, "Electrodeposited iridium oxide pH electrode formeasurement of extracellular myocardial acidosis during acute ischemia," Anal. Chem. 70, 5054-5061 (1998).
    • (1998) Anal. Chem. , vol.70 , pp. 5054-5061
    • Marzouk, S.A.M.1    Ufer, S.2    Buck, R.P.3    Johnson, T.A.4    Dunlap, L.A.5    Cascio, W.E.6
  • 9
    • 1142291661 scopus 로고    scopus 로고
    • Micromachined arrays of cantilevered glass probes
    • P. Srinivasan, F. R. Beyette, Jr and I. Papautsky, "Micromachined arrays of cantilevered glass probes," Appl. Opt. 43, 776-782 (2004).
    • (2004) Appl. Opt. , vol.43 , pp. 776-782
    • Srinivasan, P.1    Beyette Jr., F.R.2    Papautsky, I.3
  • 10
    • 0037444614 scopus 로고    scopus 로고
    • Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates
    • DOI 10.1021/ac0261404
    • S. A. M. Marzouk, "Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates," Anal. Chem. 75, 1258-1266 (2003). (Pubitemid 36397156)
    • (2003) Analytical Chemistry , vol.75 , Issue.6 , pp. 1258-1266
    • Marzouk, S.A.M.1
  • 11
    • 61849156391 scopus 로고    scopus 로고
    • A cobalt-coated needle-type microelectrode array sensor for in situ monthnitoring of phosphate
    • J.-H. Lee, W.-H. Lee, P. L. Bishop, and I. Papautsky, "A cobalt-coated needle-type microelectrode array sensor for in situ monthnitoring of phosphate," J. Micromech. Microeng. 19, 025022 (2009).
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 025022
    • Lee, J.-H.1    Lee, W.-H.2    Bishop, P.L.3    Papautsky, I.4
  • 12
    • 0031804537 scopus 로고    scopus 로고
    • Stratification of microbial metabolic processes and redox potential chance in an aerobic biofilm studied using microelectrodes
    • T. Yu and P. L. Bishop, "Stratification of microbial metabolic processes and redox potential chance in an aerobic biofilm studied using microelectrodes," Water Sci. Technol. 37, 195-198 (1998).
    • (1998) Water Sci. Technol. , vol.37 , pp. 195-198
    • Yu, T.1    Bishop, P.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.