메뉴 건너뛰기




Volumn , Issue , 2011, Pages 2249-2254

A soft wearable robot for tremor assessment and suppression

Author keywords

[No Author keywords available]

Indexed keywords

CONCEPT DESIGNS; CURRENT TREATMENTS; EFFECTIVE ATTENUATION; FUNCTIONAL ELECTRICAL STIMULATION; FUNCTIONAL PROBLEMS; NEUROMUSCULOSKELETAL SYSTEM; PATHOLOGICAL TREMORS; VOLUNTARY MOVEMENT; WEARABLE ROBOTS;

EID: 80055036940     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICRA.2011.5979639     Document Type: Conference Paper
Times cited : (38)

References (24)
  • 2
    • 3442893351 scopus 로고    scopus 로고
    • Pathological tremor management: Modelling, compensatory technology and evaluation
    • E. Rocon, J. M. Belda-Lois, J. M. Sanchez-Lacuesta, and J. L. Pons, "Pathological tremor management: Modelling, compensatory technology and evaluation," Tech Disab, vol. 16, pp. 3-18, 2004.
    • (2004) Tech Disab , vol.16 , pp. 3-18
    • Rocon, E.1    Belda-Lois, J.M.2    Sanchez-Lacuesta, J.M.3    Pons, J.L.4
  • 3
    • 70350442003 scopus 로고    scopus 로고
    • Essential tremors: A family of neurodegenerative disorders?
    • E. D. Louis, "Essential tremors: a family of neurodegenerative disorders?" Arch Neurol, vol. 66, no. 10, pp. 1202-1208, 2009.
    • (2009) Arch Neurol , vol.66 , Issue.10 , pp. 1202-1208
    • Louis, E.D.1
  • 4
    • 0842299568 scopus 로고    scopus 로고
    • Hemorrhagic complications of microelectrode-guided deep brain stimulation
    • D. K. Binder, G. Rau, and P. A. Starr, "Hemorrhagic complications of microelectrode-guided deep brain stimulation," Stereotact Funct Neurosurg, vol. 30, pp. 28-31, 2003.
    • (2003) Stereotact Funct Neurosurg , vol.30 , pp. 28-31
    • Binder, D.K.1    Rau, G.2    Starr, P.A.3
  • 5
    • 34648858599 scopus 로고    scopus 로고
    • Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression
    • E. Rocon, J. M. Belda-Lois, A. F. Ruiz, M. Manto, J. C. Moreno, and J. L. Pons, "Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression," IEEE Tans Neural Syst Rehab Eng, vol. 15, no. 3, pp. 367-378, 2007.
    • (2007) IEEE Tans Neural Syst Rehab Eng , vol.15 , Issue.3 , pp. 367-378
    • Rocon, E.1    Belda-Lois, J.M.2    Ruiz, A.F.3    Manto, M.4    Moreno, J.C.5    Pons, J.L.6
  • 6
    • 0016244446 scopus 로고
    • The effects of load and force on tremor at the normal human elbow joint
    • G. C. Joyce and P. M. H. Rack, "The effects of load and force on tremor at the normal human elbow joint," J Physiol, vol. 240, pp. 375-396, 1974.
    • (1974) J Physiol , vol.240 , pp. 375-396
    • Joyce, G.C.1    Rack, P.M.H.2
  • 7
    • 0026506746 scopus 로고
    • Attenuation of pathological tremors by functional electrical stimulation. I: Method
    • A. Prochazka, J. Elek, and M. Javidan, "Attenuation of pathological tremors by functional electrical stimulation. i: Method." Ann Biomed Eng, vol. 20, no. 2, pp. 205-224, 1992.
    • (1992) Ann Biomed Eng , vol.20 , Issue.2 , pp. 205-224
    • Prochazka, A.1    Elek, J.2    Javidan, M.3
  • 11
    • 24944440860 scopus 로고    scopus 로고
    • Multi-field surface electrode for selective electrical stimulation
    • A. Popovic-Bijelic, G. Bijelic, N. Jorgovanovic, D. Bojanic, M. B. Popovic, and D. B. Popovic, "Multi-field surface electrode for selective electrical stimulation." Artif Organs, vol. 29, no. 6, pp. 448-452, 2005. [Online]. Available: http://dx.doi.org/10.1111/j.1525-1594.2005.29075.x
    • (2005) Artif Organs , vol.29 , Issue.6 , pp. 448-452
    • Popovic-Bijelic, A.1    Bijelic, G.2    Jorgovanovic, N.3    Bojanic, D.4    Popovic, M.B.5    Popovic, D.B.6
  • 12
    • 34047210440 scopus 로고    scopus 로고
    • Evaluation of a wearable orthosis and an associated algorithm for tremor suppression
    • M. Manto, E. Rocon, J. L. Pons, J. M. Belda-Lois, and S. Camut, "Evaluation of a wearable orthosis and an associated algorithm for tremor suppression." Physiol Meas, vol. 28, no. 4, pp. 415-425, 2007. [Online]. Available: http://dx.doi.org/10.1088/0967-3334/28/4/007
    • (2007) Physiol Meas , vol.28 , Issue.4 , pp. 415-425
    • Manto, M.1    Rocon, E.2    Pons, J.L.3    Belda-Lois, J.M.4    Camut, S.5
  • 13
    • 0032829330 scopus 로고    scopus 로고
    • Event-related eeg/meg synchronization and desynchronization: Basic principles
    • G. Pfurtscheller and F. H. Lopes da Silva, "Event-related eeg/meg synchronization and desynchronization: basic principles," Clin Neurophysiol, vol. 110, no. 11, pp. 1842-1857, 1999. [Online]. Available: http://www.sciencedirect.com/science/article/B6VNP-3XJSSG7-1/2/ 919fb705601eee998c08fc2160dc2f99
    • (1999) Clin Neurophysiol , vol.110 , Issue.11 , pp. 1842-1857
    • Pfurtscheller, G.1    Lopes Da Silva, F.H.2
  • 15
    • 0023313742 scopus 로고
    • Evaluating manual control devices for those with tremor disability
    • P. O. Riley and M. J. Rosen, "Evaluating manual control devices for those with tremor disability," J Rehabil Res Dev, vol. 24, no. 2, pp. 99-110, 1987.
    • (1987) J Rehabil Res Dev , vol.24 , Issue.2 , pp. 99-110
    • Riley, P.O.1    Rosen, M.J.2
  • 16
    • 0032126585 scopus 로고    scopus 로고
    • Adaptive canceling of physiological tremor for improved precision in microsurgery
    • C. N. Riviere, R. S. Rader, and N. V. Thakor, "Adaptive canceling of physiological tremor for improved precision in microsurgery," IEEE Trans Biomed Eng, vol. 45, no. 7, pp. 839-846, 1998.
    • (1998) IEEE Trans Biomed Eng , vol.45 , Issue.7 , pp. 839-846
    • Riviere, C.N.1    Rader, R.S.2    Thakor, N.V.3
  • 17
    • 34648836473 scopus 로고    scopus 로고
    • Biomechanical modelling of the upper limb for robotics-based orthotic tremor suppression
    • E. Rocon, R. A. F., and P. J. L., "Biomechanical modelling of the upper limb for robotics-based orthotic tremor suppression," Appl Bionics Biomech, vol. 2, no. 2, pp. 81-85, 2005.
    • (2005) Appl Bionics Biomech , vol.2 , Issue.2 , pp. 81-85
    • Rocon, E.1    F, R.A.2    P, J.L.3
  • 18
    • 0021479511 scopus 로고
    • Adaptive control of mechanical impedance by coactivation of antagonist muscles
    • aug
    • N. Hogan, "Adaptive control of mechanical impedance by coactivation of antagonist muscles," IEEE Trans Autom Control, vol. 29, no. 8, pp. 681-690, aug 1984.
    • (1984) IEEE Trans Autom Control , vol.29 , Issue.8 , pp. 681-690
    • Hogan, N.1
  • 19
    • 0024051135 scopus 로고
    • Repetitive control system: A new type servo system for periodic exogenous signals
    • jul
    • S. Hara, Y. Yamamoto, T. Omata, and M. Nakano, "Repetitive control system: a new type servo system for periodic exogenous signals," IEEE Trans Autom Control, vol. 33, no. 7, pp. 659-668, jul 1988.
    • (1988) IEEE Trans Autom Control , vol.33 , Issue.7 , pp. 659-668
    • Hara, S.1    Yamamoto, Y.2    Omata, T.3    Nakano, M.4
  • 22
    • 77955498702 scopus 로고    scopus 로고
    • Realtime estimation of pathological tremor parameters from gyroscope data
    • J. A. Gallego, E. Rocon, J. O. Roa, J. C. Moreno, and J. L. Pons, "Realtime estimation of pathological tremor parameters from gyroscope data," Sensors, vol. 10, no. 3, pp. 2129-2149, 2010.
    • (2010) Sensors , vol.10 , Issue.3 , pp. 2129-2149
    • Gallego, J.A.1    Rocon, E.2    Roa, J.O.3    Moreno, J.C.4    Pons, J.L.5
  • 24
    • 73849151044 scopus 로고    scopus 로고
    • Concurrent adaptation of force and impedance in the redundant muscle system
    • K. P. Tee, D. W. Franklin, T. Milner, M. Kawato, and E. Burdet, "Concurrent adaptation of force and impedance in the redundant muscle system," Biol Cybern, vol. 102, pp. 31-44, 2010.
    • (2010) Biol Cybern , vol.102 , pp. 31-44
    • Tee, K.P.1    Franklin, D.W.2    Milner, T.3    Kawato, M.4    Burdet, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.