메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1528-1531

Retrospective registration-based MRI motion correction with interleaved radial trajectories

Author keywords

center of mass; motion correction; projection moments; radial MRI; registration

Indexed keywords

CENTER OF MASS; MOTION CORRECTION; PROJECTION MOMENTS; RADIAL MRI; REGISTRATION;

EID: 80055029445     PISSN: 19457928     EISSN: 19458452     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2011.5872692     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Dec.
    • G. H. Glover and J. M. Pauly, "Projection Reconstruction Techniques for Reduction of Motion Effects in MRI," Magnetic Resonance in Medicine, vol. 28, pp. 275-89, Dec. 1992.
    • (1992) Magnetic Resonance in Medicine , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 2
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Nov.
    • J. G. Pipe, "Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging," Magnetic Resonance in Medicine, vol. 42, pp. 963-9, Nov. 1999.
    • (1999) Magnetic Resonance in Medicine , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 3
    • 10044240735 scopus 로고    scopus 로고
    • Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
    • Dec.
    • C. Liu, R. Bammer, D.-H. Kim, and M. E. Moseley, "Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging," Magnetic Resonance in Medicine, vol. 52, pp. 1388-96, Dec. 2004.
    • (2004) Magnetic Resonance in Medicine , vol.52 , pp. 1388-1396
    • Liu, C.1    Bammer, R.2    Kim, D.-H.3    Moseley, M.E.4
  • 4
    • 0030047957 scopus 로고    scopus 로고
    • Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints
    • N. Gai and L. Axel, "Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints," Medical Physics, vol. 23, no. 2, pp. 251-62, 1996.
    • (1996) Medical Physics , vol.23 , Issue.2 , pp. 251-262
    • Gai, N.1    Axel, L.2
  • 6
    • 0032081266 scopus 로고    scopus 로고
    • Design and construction of a realistic digital brain phantom
    • D. L. Collins, A. P. Zijdenbos, et al., "Design and construction of a realistic digital brain phantom," IEEE Transactions on Medical Imaging, vol. 17, no. 3, pp. 463-468, 1998.
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.3 , pp. 463-468
    • Collins, D.L.1    Zijdenbos, A.P.2
  • 7
    • 0035384136 scopus 로고    scopus 로고
    • A global optimisation method for robust affine registration of brain images
    • June
    • M. Jenkinson and S. Smith, "A global optimisation method for robust affine registration of brain images," Medical Image Analysis, vol. 5, pp. 143-56, June 2001.
    • (2001) Medical Image Analysis , vol.5 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 8
    • 80055058377 scopus 로고    scopus 로고
    • The effect of navigator resolution on registration accuracy in rigid head motion correction
    • Berlin
    • M. Aksoy, C. Liu, M. E. Moseley, and R. Bammer, "The Effect of Navigator Resolution on Registration Accuracy in Rigid Head Motion Correction," in Proc. ISMRM 15, Berlin, p. 3424, 2007.
    • (2007) Proc. ISMRM 15 , pp. 3424
    • Aksoy, M.1    Liu, C.2    Moseley, M.E.3    Bammer, R.4
  • 9
    • 33846167110 scopus 로고    scopus 로고
    • Augmented generalized SENSE reconstruction to correct for rigid body motion
    • Jan.
    • R. Bammer, M. Aksoy, and C. Liu, "Augmented generalized SENSE reconstruction to correct for rigid body motion," Magnetic Resonance in Medicine, vol. 57, pp. 90-102, Jan. 2007.
    • (2007) Magnetic Resonance in Medicine , vol.57 , pp. 90-102
    • Bammer, R.1    Aksoy, M.2    Liu, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.