-
1
-
-
0027093023
-
Projection reconstruction techniques for reduction of motion effects in MRI
-
Dec.
-
G. H. Glover and J. M. Pauly, "Projection Reconstruction Techniques for Reduction of Motion Effects in MRI," Magnetic Resonance in Medicine, vol. 28, pp. 275-89, Dec. 1992.
-
(1992)
Magnetic Resonance in Medicine
, vol.28
, pp. 275-289
-
-
Glover, G.H.1
Pauly, J.M.2
-
2
-
-
0032754594
-
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
-
Nov.
-
J. G. Pipe, "Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging," Magnetic Resonance in Medicine, vol. 42, pp. 963-9, Nov. 1999.
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, pp. 963-969
-
-
Pipe, J.G.1
-
3
-
-
10044240735
-
Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
-
Dec.
-
C. Liu, R. Bammer, D.-H. Kim, and M. E. Moseley, "Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging," Magnetic Resonance in Medicine, vol. 52, pp. 1388-96, Dec. 2004.
-
(2004)
Magnetic Resonance in Medicine
, vol.52
, pp. 1388-1396
-
-
Liu, C.1
Bammer, R.2
Kim, D.-H.3
Moseley, M.E.4
-
4
-
-
0030047957
-
Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints
-
N. Gai and L. Axel, "Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints," Medical Physics, vol. 23, no. 2, pp. 251-62, 1996.
-
(1996)
Medical Physics
, vol.23
, Issue.2
, pp. 251-262
-
-
Gai, N.1
Axel, L.2
-
5
-
-
0344258185
-
Motion compensated projection reconstruction
-
May
-
T. Schäffter, V. Rasche, and I. C. Carlsen, "Motion compensated projection reconstruction," Magnetic Resonance in Medicine, vol. 41, pp. 954-63, May 1999.
-
(1999)
Magnetic Resonance in Medicine
, vol.41
, pp. 954-963
-
-
Schäffter, T.1
Rasche, V.2
Carlsen, I.C.3
-
6
-
-
0032081266
-
Design and construction of a realistic digital brain phantom
-
D. L. Collins, A. P. Zijdenbos, et al., "Design and construction of a realistic digital brain phantom," IEEE Transactions on Medical Imaging, vol. 17, no. 3, pp. 463-468, 1998.
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, Issue.3
, pp. 463-468
-
-
Collins, D.L.1
Zijdenbos, A.P.2
-
7
-
-
0035384136
-
A global optimisation method for robust affine registration of brain images
-
June
-
M. Jenkinson and S. Smith, "A global optimisation method for robust affine registration of brain images," Medical Image Analysis, vol. 5, pp. 143-56, June 2001.
-
(2001)
Medical Image Analysis
, vol.5
, pp. 143-156
-
-
Jenkinson, M.1
Smith, S.2
-
8
-
-
80055058377
-
The effect of navigator resolution on registration accuracy in rigid head motion correction
-
Berlin
-
M. Aksoy, C. Liu, M. E. Moseley, and R. Bammer, "The Effect of Navigator Resolution on Registration Accuracy in Rigid Head Motion Correction," in Proc. ISMRM 15, Berlin, p. 3424, 2007.
-
(2007)
Proc. ISMRM 15
, pp. 3424
-
-
Aksoy, M.1
Liu, C.2
Moseley, M.E.3
Bammer, R.4
-
9
-
-
33846167110
-
Augmented generalized SENSE reconstruction to correct for rigid body motion
-
Jan.
-
R. Bammer, M. Aksoy, and C. Liu, "Augmented generalized SENSE reconstruction to correct for rigid body motion," Magnetic Resonance in Medicine, vol. 57, pp. 90-102, Jan. 2007.
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, pp. 90-102
-
-
Bammer, R.1
Aksoy, M.2
Liu, C.3
-
10
-
-
77950612706
-
POCS-enhanced correction of motion artifacts in parallel MRI
-
Apr.
-
A. A. Samsonov, J. Velikina, Y. Jung, E. G. Kholmovski, C. R. Johnson, and W. F. Block, "POCS-enhanced correction of motion artifacts in parallel MRI," Magnetic Resonance in Medicine, vol. 63, pp. 1104-10, Apr. 2010.
-
(2010)
Magnetic Resonance in Medicine
, vol.63
, pp. 1104-1110
-
-
Samsonov, A.A.1
Velikina, J.2
Jung, Y.3
Kholmovski, E.G.4
Johnson, C.R.5
Block, W.F.6
|