-
1
-
-
35848943288
-
The ther-mal conductivity of prosthetic sockets and liners
-
[PMID: 17979015] DOI:10.1080/03093640601042554
-
Klute GK, Rowe GI, Mamishev AV, Ledoux WR. The ther-mal conductivity of prosthetic sockets and liners. Prosthet Orthot Int. 2007;31(3):292-99. [PMID: 17979015] DOI:10.1080/03093640601042554
-
(2007)
Prosthet Orthot Int.
, vol.31
, Issue.3
, pp. 292-299
-
-
Klute, G.K.1
Rowe, G.I.2
Mamishev, A.V.3
Ledoux, W.R.4
-
2
-
-
34447565228
-
CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?
-
[PMID: 18247236] DOI:10.1682/JRRD.2006.06.0069
-
Sanders JE, Rogers EL, Sorenson EA, Lee GS, Abrahamson DC. CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they? J Rehabil Res Dev. 2007;44(3):395-405. [PMID: 18247236] DOI:10.1682/JRRD.2006.06.0069
-
(2007)
J Rehabil Res Dev.
, vol.44
, Issue.3
, pp. 395-405
-
-
Sanders, J.E.1
Rogers, E.L.2
Sorenson, E.A.3
Lee, G.S.4
Abrahamson, D.C.5
-
3
-
-
80055032982
-
Lower-limb prosthetics-Mechanical testing pros-thetic sockets
-
2005 Mar 16-19; Orlando, FL; Journal of Proceedings. Washington (DC): American Academy of Orthotists & Prosthetists
-
Taylor D. Lower-limb prosthetics-Mechanical testing pros-thetic sockets. 2005 Journal of Proceedings; 2005 Mar 16-19; Orlando, FL; Journal of Proceedings. Washington (DC): American Academy of Orthotists & Prosthetists; 2005. p. 34-37.
-
(2005)
2005 Journal of Proceedings
, pp. 34-37
-
-
Taylor, D.1
-
5
-
-
13244253798
-
Material properties of selected prosthetic laminates
-
DOI:10.1097/00008526-200501000-00007
-
Phillips SL, Craelius W. Material properties of selected prosthetic laminates. J Prosthet Orthot. 2005;17(1):27-33. DOI:10.1097/00008526-200501000-00007
-
(2005)
J Prosthet Orthot.
, vol.17
, Issue.1
, pp. 27-33
-
-
Phillips, S.L.1
Craelius, W.2
-
6
-
-
0029115724
-
Carbon fibre and fibre lamination in prosthet-ics and orthotics: Some basic theory and practical advice for the practitioner
-
[PMID: 8570384]
-
Klasson BL. Carbon fibre and fibre lamination in prosthet-ics and orthotics: Some basic theory and practical advice for the practitioner. Prosthet Orthot Int. 1995;19(2):74-91. [PMID: 8570384]
-
(1995)
Prosthet Orthot Int.
, vol.19
, Issue.2
, pp. 74-91
-
-
Klasson, B.L.1
-
7
-
-
80055062594
-
Use of copolymer for interfaces in all levels of prosthetic applications
-
DOI:10.1097/00008526-199000310-00007
-
Rosenberg RJ, Terry R. Use of copolymer for interfaces in all levels of prosthetic applications. J Prosthet Orthot. 1999; 3(1):22-25. DOI:10.1097/00008526-199000310-00007
-
(1999)
J Prosthet Orthot.
, vol.3
, Issue.1
, pp. 22-25
-
-
Rosenberg, R.J.1
Terry, R.2
-
8
-
-
0012025673
-
Thermoplastic applications in lower extremity prosthetics
-
DOI:10.1097/00008526-199000310-00004
-
Schuch CM. Thermoplastic applications in lower extremity prosthetics. J Prosthet Orthot. 1990;3(1):1-8. DOI:10.1097/00008526-199000310-00004
-
(1990)
J Prosthet Orthot.
, vol.3
, Issue.1
, pp. 1-8
-
-
Schuch, C.M.1
-
9
-
-
0035018006
-
Lower limb amputation. Part 3: Prosthetics-A 10 year literature review
-
[PMID: 11411001] DOI:10.1080/03093640108726564
-
Cochrane H, Orsi K, Reilly P. Lower limb amputation. Part 3: Prosthetics-A 10 year literature review. Prosthet Orthot Int. 2001;25(1):21-28. [PMID: 11411001] DOI:10.1080/03093640108726564
-
(2001)
Prosthet Orthot Int.
, vol.25
, Issue.1
, pp. 21-28
-
-
Cochrane, H.1
Orsi, K.2
Reilly, P.3
-
10
-
-
0003606769
-
-
ASTM Standard D-638, West Consho-hocken (PA): ASTM International. Available from
-
ASTM Standard D-638, 2008. Standard test method for tensile properties of plastics [Internet]. West Consho-hocken (PA): ASTM International. Available from: http://www.astm.org/.
-
(2008)
Standard test method for tensile properties of plastics [Internet]
-
-
-
13
-
-
0033747978
-
Predictive modelling of the properties and toughness of polymeric materials. Part II: Effect of microstructural properties on the macroscopic response of rubber-modified polymers
-
DOI:10.1023/A:1004763606229
-
Smit RJ, Brekelmans WA, Meijer HE. Predictive modelling of the properties and toughness of polymeric materials. Part II: Effect of microstructural properties on the macroscopic response of rubber-modified polymers. J Mater Sci. 2000; 35(11):2869-79. DOI:10.1023/A:1004763606229
-
(2000)
J Mater Sci.
, vol.35
, Issue.11
, pp. 2869-2879
-
-
Smit, R.J.1
Brekelmans, W.A.2
Meijer, H.E.3
-
15
-
-
0038363901
-
Localisation phe-nomena in glassy polymers: Influence of thermal and mechanical history
-
DOI:10.1016/S0032-3861(03)00089-2
-
Van Melick HG, Govert LE, Meijer HE. Localisation phe-nomena in glassy polymers: Influence of thermal and mechanical history. Polymer. 2003;44(12):3579-91. DOI:10.1016/S0032-3861(03)00089-2
-
(2003)
Polymer.
, vol.44
, Issue.12
, pp. 3579-3591
-
-
van Melick, H.G.1
Govert, L.E.2
Meijer, H.E.3
-
16
-
-
84859889492
-
-
VIVAK sheet [Internet]. Sheffield (MA); Sheffield Plastics Inc, [cited 2010 Jun 30]. Available from
-
VIVAK sheet [Internet]. Sheffield (MA); Sheffield Plastics Inc; 2003 [cited 2010 Jun 30]. Available from: http://www.framersbrand.com/docs/VivakDataSheet.pdf.
-
(2003)
-
-
-
17
-
-
84859910068
-
-
Wijnegem (Belgium): Orfit Industries; [cited 2010 Jun 30]. Available from
-
Thermoplastics for medical applications [Internet]. Wijnegem (Belgium): Orfit Industries; [cited 2010 Jun 30]. Available from: http://www.orfit.com/en/orthopedie/index.html.
-
Thermoplastics for medical applications [Internet]
-
-
|