메뉴 건너뛰기




Volumn 44, Issue 3, 2007, Pages 395-405

CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?

Author keywords

AAOP; Amputee; Assessment; Digitizer; Fabrication; Patellar tendon bearing; Prosthesis; Rehabilitation; Residual limb; Shape; Volume

Indexed keywords

DIGITIZERS; MANUFACTURING ERRORS; RESIDUAL LIMB; TRANSTIBIAL PROSTHETIC SOCKETS;

EID: 34447565228     PISSN: 07487711     EISSN: 07487711     Source Type: Journal    
DOI: 10.1682/JRRD.2006.06.0069     Document Type: Article
Times cited : (32)

References (6)
  • 1
    • 0036586639 scopus 로고    scopus 로고
    • Presentation highlights: Computer-Aided Design and Manufacture (CAD-CAM)
    • Childress DS. Presentation highlights: Computer-Aided Design and Manufacture (CAD-CAM). J Rehabil Res Dev. 2002;39(3 Suppl):15-16.
    • (2002) J Rehabil Res Dev , vol.39 , Issue.3 SUPPL. , pp. 15-16
    • Childress, D.S.1
  • 2
    • 0035704756 scopus 로고    scopus 로고
    • The use of CAD/CAM technology in prosthetics and orthotics - Current clinical models and a view to the future
    • Smith DG, Burgess EM. The use of CAD/CAM technology in prosthetics and orthotics - Current clinical models and a view to the future. J Rehabil Res Dev. 2001;38(3):327-34.
    • (2001) J Rehabil Res Dev , vol.38 , Issue.3 , pp. 327-334
    • Smith, D.G.1    Burgess, E.M.2
  • 3
    • 0037739794 scopus 로고    scopus 로고
    • A digitizer with exceptional accuracy for use in prosthetics research: A technical note
    • Sanders JE, Mitchell SB, Zachariah SG, Wu K. A digitizer with exceptional accuracy for use in prosthetics research: A technical note. J Rehabil Res Dev. 2003;40(2):191-95.
    • (2003) J Rehabil Res Dev , vol.40 , Issue.2 , pp. 191-195
    • Sanders, J.E.1    Mitchell, S.B.2    Zachariah, S.G.3    Wu, K.4
  • 4
    • 29544450968 scopus 로고    scopus 로고
    • A method for aligning trans-tibial residual limb shapes so as to identify regions of shape change
    • Zachariah SG, Sorenson E, Sanders JE. A method for aligning trans-tibial residual limb shapes so as to identify regions of shape change. IEEE Trans Neural Syst Rehabil Eng. 2005;13(4):551-57.
    • (2005) IEEE Trans Neural Syst Rehabil Eng , vol.13 , Issue.4 , pp. 551-557
    • Zachariah, S.G.1    Sorenson, E.2    Sanders, J.E.3
  • 6
    • 0020050715 scopus 로고
    • Volume fluctuations in the residual limbs of lower limb amputees
    • Fernie GR, Holliday PJ. Volume fluctuations in the residual limbs of lower limb amputees. Arch Phys Med Rehabil. 1982;63(4):162-65.
    • (1982) Arch Phys Med Rehabil , vol.63 , Issue.4 , pp. 162-165
    • Fernie, G.R.1    Holliday, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.