메뉴 건너뛰기




Volumn 78, Issue 5, 2011, Pages 770-776

Occupational radiation dose during transcatheter aortic valve implantation

Author keywords

radiation dose; TAVI; transapical; transcatheter aortic valve implantation; transfemoral

Indexed keywords

ARTICLE; CARDIOLOGIST; CONTROLLED STUDY; DISEASE ASSOCIATION; DOSIMETRY; FEMALE; HEALTH CARE PERSONNEL; HUMAN; LIMIT OF DETECTION; MALE; OCCUPATIONAL EXPOSURE; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIOLOGICAL PROCEDURES; STANDARD; SURGEON; THERMOLUMINESCENCE DOSIMETER; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 80055024864     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.23116     Document Type: Article
Times cited : (28)

References (25)
  • 1
    • 77955617014 scopus 로고    scopus 로고
    • Predictors for new-onset complete heart block after transcatheter aortic valve implantation
    • Bleiziffer S, Ruge H, Horer J, et al. Predictors for new-onset complete heart block after transcatheter aortic valve implantation. JACC Cardiovasc Interv 2010; 3: 524-530.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 524-530
    • Bleiziffer, S.1    Ruge, H.2    Horer, J.3
  • 2
    • 33746862304 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation in humans: Initial clinical experience
    • DOI 10.1161/CIRCULATIONAHA.106.632927, PII 0000301720060808000012
    • Lichtenstein SV, Cheung A, Ye J, et al. Transapical transcatheter aortic valve implantation in humans: Initial clinical experience. Circulation 2006; 114: 591-596. (Pubitemid 44202060)
    • (2006) Circulation , vol.114 , Issue.6 , pp. 591-596
    • Lichtenstein, S.V.1    Cheung, A.2    Ye, J.3    Thompson, C.R.4    Carere, R.G.5    Pasupati, S.6    Webb, J.G.7
  • 4
    • 41549125589 scopus 로고    scopus 로고
    • Transcatheter Percutaneous and Transapical Aortic Valve Replacement
    • DOI 10.1053/j.semtcvs.2007.11.001, PII S1043067907001554
    • Webb JG, Lichtenstein S,. Transcatheter percutaneous and transapical aortic valve replacement. Semin Thorac Cardiovasc Surg 2007; 19: 304-310. (Pubitemid 351467403)
    • (2007) Seminars in Thoracic and Cardiovascular Surgery , vol.19 , Issue.4 , pp. 304-310
    • Webb, J.G.1    Lichtenstein, S.2
  • 5
    • 41049090061 scopus 로고    scopus 로고
    • Occupational radiation doses to operators performing cardiac catheterization procedures
    • DOI 10.1097/01.HP.0000290614.76386.35, PII 0000403220080300000001
    • Kim KP, Miller DL, Balter S, et al. Occupational radiation doses to operators performing cardiac catheterization procedures. Health Phys 2008; 94: 211-227. (Pubitemid 351643132)
    • (2008) Health Physics , vol.94 , Issue.3 , pp. 211-227
    • Kim, K.P.1    Miller, D.L.2    Balter, S.3    Kleinerman, R.A.4    Linet, M.S.5    Kwon, D.6    Simon, S.L.7
  • 6
    • 55249126176 scopus 로고    scopus 로고
    • An overview on extremity dosimetry in medical applications
    • Vanhavere F, Carinou E, Donadille L, et al. An overview on extremity dosimetry in medical applications. Radiat Prot Dosimetry 2008; 129: 350-355.
    • (2008) Radiat Prot Dosimetry , vol.129 , pp. 350-355
    • Vanhavere, F.1    Carinou, E.2    Donadille, L.3
  • 7
    • 68149180914 scopus 로고    scopus 로고
    • Assessment of radiation doses to cardiologists during interventional examinations
    • Bor D, Olgar T, Onal E, Caglan A, Toklu T,. Assessment of radiation doses to cardiologists during interventional examinations. Med Phys 2009; 36: 3730-3736.
    • (2009) Med Phys , vol.36 , pp. 3730-3736
    • Bor, D.1    Olgar, T.2    Onal, E.3    Caglan, A.4    Toklu, T.5
  • 9
    • 0742271723 scopus 로고    scopus 로고
    • Application of ALARP to extremity doses for hospital workers
    • DOI 10.1088/0952-4746/23/4/004, PII S0952474603697661
    • Martin CJ, Whitby M,. Application of ALARP to extremity doses for hospital workers. J Radiol Prot 2003; 23: 405-421. (Pubitemid 38145609)
    • (2003) Journal of Radiological Protection , vol.23 , Issue.4 , pp. 405-421
    • Martin, C.J.1    Whitby, M.2
  • 10
    • 16344376565 scopus 로고    scopus 로고
    • A study of the distribution of dose across the hands of interventional radiologists and cardiologists
    • DOI 10.1259/bjr/12209589
    • Whitby M, Martin CJ,. A study of the distribution of dose across the hands of interventional radiologists and cardiologists. Br J Radiol 2005; 78: 219-229. (Pubitemid 40467643)
    • (2005) British Journal of Radiology , vol.78 , Issue.927 , pp. 219-229
    • Whitby, M.1    Martin, C.J.2
  • 12
    • 2642682425 scopus 로고    scopus 로고
    • Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories
    • Vano E, Gonzalez L, Beneytez F, Moreno F,. Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories. Br J Radiol 1998; 71: 728-733. (Pubitemid 28342458)
    • (1998) British Journal of Radiology , vol.71 , Issue.JULY , pp. 728-733
    • Vano, E.1    Gonzalez, L.2    Beneytez, F.3    Moreno, F.4
  • 14
    • 65549153330 scopus 로고    scopus 로고
    • Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: A review
    • Kim KP, Miller DL,. Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: A review. Radiat Prot Dosimetry 2009; 133: 227-233.
    • (2009) Radiat Prot Dosimetry , vol.133 , pp. 227-233
    • Kim, K.P.1    Miller, D.L.2
  • 15
    • 0031797811 scopus 로고    scopus 로고
    • Is brain cancer an occupational disease of cardiologists?
    • Finkelstein MM,. Is brain cancer an occupational disease of cardiologists? Can J Cardiol 1998; 14: 1385-1388. (Pubitemid 28552367)
    • (1998) Canadian Journal of Cardiology , vol.14 , Issue.11 , pp. 1385-1388
    • Finkelstein, M.M.1
  • 17
    • 67649993970 scopus 로고    scopus 로고
    • Guidelines for patient radiation dose management
    • Stecker MS, Balter S, Towbin RB, et al. Guidelines for patient radiation dose management. J Vasc Interv Radiol 2009; 20 (7 Suppl): S263-S273.
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.7 SUPPL.
    • Stecker, M.S.1    Balter, S.2    Towbin, R.B.3
  • 18
    • 77955592899 scopus 로고    scopus 로고
    • Occupational radiation protection in interventional radiology: A joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    • Miller DL, Vano E, Bartal G, et al. Occupational radiation protection in interventional radiology: A joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology. J Vasc Interv Radiol 21: 607-615.
    • J Vasc Interv Radiol , vol.21 , pp. 607-615
    • Miller, D.L.1    Vano, E.2    Bartal, G.3
  • 19
    • 84857794560 scopus 로고    scopus 로고
    • Netherlands Commission on Radiation Dosimetry, Code of practice for personal dosimetry of professionals wearing protective clothing during radiological procedures, Report 19 of the Netherlands Commission on Radiation Dosimetry 2008. Available at
    • Netherlands Commission on Radiation Dosimetry, Code of practice for personal dosimetry of professionals wearing protective clothing during radiological procedures, Available at http://www.stralingsdosimetrie.nl/assets/ files/ncs-report/ NCS%20Rapport%2019%20CoP%20Personal%20Dosimetry%20Protective%20Clothing.pdf.
    • Report 19 of the Netherlands Commission on Radiation Dosimetry 2008
  • 20
    • 33745685928 scopus 로고    scopus 로고
    • Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters
    • DOI 10.1093/rpd/ncl018
    • Schultz FW, Zoetelief J,. Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters. Radiat Prot Dosimetry 2006; 118: 196-204. (Pubitemid 43997425)
    • (2006) Radiation Protection Dosimetry , vol.118 , Issue.2 , pp. 196-204
    • Schultz, F.W.1    Zoetelief, J.2
  • 21
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • Webb JG, Chandavimol M, Thompson CR, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 2006; 113: 842-850.
    • (2006) Circulation , vol.113 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 23
    • 0036147427 scopus 로고    scopus 로고
    • Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding
    • DOI 10.1016/S0002-9149(01)02161-0, PII S0002914901021610
    • Kuon E, Schmitt M, Dahm JB,. Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding. Am J Cardiol 2002; 89: 44-49. (Pubitemid 34066585)
    • (2002) American Journal of Cardiology , vol.89 , Issue.1 , pp. 44-49
    • Kuon, E.1    Schmitt, M.2    Dahm, J.B.3
  • 24
    • 80054992257 scopus 로고    scopus 로고
    • Stralingsbelasting voor de interventiecardioloog
    • Frantzen-Wilmes M,. Stralingsbelasting voor de interventiecardioloog. Gamma Professional 2009; 59: 22-26.
    • (2009) Gamma Professional , vol.59 , pp. 22-26
    • Frantzen-Wilmes, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.