1
-
-
0016704109
-
Exposure of the radiologist to scattered radiation during angiography
-
Santen BC, Kan K, Velthuyse JM, Julius HW. Exposure of the radiologist to scattered radiation during angiography. Radiat Phys 1975;115:447-50.
-
(1975)
Radiat. Phys.
, vol.115
, pp. 447-450
-
-
Santen, B.C.1
Kan, K.2
Velthuyse, J.M.3
Julius, H.W.4
-
2
-
-
0018828166
-
Finger doses received by radiologists during Chiba needle percutaneous cholangiography
-
Cruikshank JG, Fraser GM, Law J. Finger doses received by radiologists during Chiba needle percutaneous cholangiography. Br J Radiol 1980;53:584-5.
-
(1980)
Br. J. Radiol.
, vol.53
, pp. 584-585
-
-
Cruikshank, J.G.1
Fraser, G.M.2
Law, J.3
-
3
-
-
0019479904
-
Personnel exposure to radiation at some angiographic procedures
-
Gustafsson M, Lunderquist A. Personnel exposure to radiation at some angiographic procedures. Radiology 1981;140:807-11.
-
(1981)
Radiology
, vol.140
, pp. 807-811
-
-
Gustafsson, M.1
Lunderquist, A.2
-
5
-
-
0023027459
-
Monitoring radiation exposure to medical personnel during percutaneous nephrolithotomy
-
Lowe FC, Auter M, Beck TJ, Chang R, Marshall FF. Monitoring radiation exposure to medical personnel during percutaneous nephrolithotomy. Urology 1986;XXVIII:221-6.
-
(1986)
Urology
, vol.28
, pp. 221-226
-
-
Lowe, F.C.1
Auter, M.2
Beck, T.J.3
Chang, R.4
Marshall, F.F.5
-
6
-
-
0023200984
-
The radiologist and angiographic procedures: Absorbed radiation dose
-
Tryhus M, Mettler FA, Kelsey C. The radiologist and angiographic procedures: absorbed radiation dose. Invest Radiol 1987;22:747-50.
-
(1987)
Invest. Radiol.
, vol.22
, pp. 747-750
-
-
Tryhus, M.1
Mettler, F.A.2
Kelsey, C.3
-
7
-
-
84970313866
-
Radiation dose to patients and personnel during fluoroscopy at percutaneous renal stone extraction
-
Geterud K, Larsson A, Mattsson S. Radiation dose to patients and personnel during fluoroscopy at percutaneous renal stone extraction. Acta Radiologica 1989;30:201-5.
-
(1989)
Acta Radiologica
, vol.30
, pp. 201-205
-
-
Geterud, K.1
Larsson, A.2
Mattsson, S.3
-
10
-
-
0026488105
-
Measuring radiation exposure during percutaneous drainages: Can should dosemeters be used to estimate finger doses?
-
Vehmas T, Tikkanen H. Measuring radiation exposure during percutaneous drainages: can should dosemeters be used to estimate finger doses? Br J Radiol 1992;66:1007-10.
-
(1992)
Br. J. Radiol.
, vol.66
, pp. 1007-1010
-
-
Vehmas, T.1
Tikkanen, H.2
-
11
-
-
0027328329
-
What factors influence radiologists' finger doses during percutaneous drainages under fluoroscopic guidance?
-
Vehmas T. What factors influence radiologists' finger doses during percutaneous drainages under fluoroscopic guidance? Health Physics 1993;65:161-3.
-
(1993)
Health Physics
, vol.65
, pp. 161-163
-
-
Vehmas, T.1
-
12
-
-
0028863543
-
Radiation exposure to the hands of operators during angiographic procedures
-
Damilakis J, Koulourakis M, Hatjidakis S, Karabekios S, Gourtsoyiannis N. Radiation exposure to the hands of operators during angiographic procedures. Br J Radiol 1995;21:72-5.
-
(1995)
Br. J. Radiol.
, vol.21
, pp. 72-75
-
-
Damilakis, J.1
Koulourakis, M.2
Hatjidakis, S.3
Karabekios, S.4
Gourtsoyiannis, N.5
-
13
-
-
0030894029
-
Radiation exposure during standard and complex interventional procedures
-
Vehmas T. Radiation exposure during standard and complex interventional procedures. Br J Radiol 1997;70:296-8.
-
(1997)
Br. J. Radiol.
, vol.70
, pp. 296-298
-
-
Vehmas, T.1
-
14
-
-
0026453144
-
Personal monitoring during fluoroscopy
-
Faulkner K. Personal monitoring during fluoroscopy. J Radiol Prot 1992;12:225-31.
-
(1992)
J. Radiol. Prot.
, vol.12
, pp. 225-231
-
-
Faulkner, K.1
-
15
-
-
0021967382
-
Doses to head and arms of radiologists during fluoroscopy
-
Law J. Doses to head and arms of radiologists during fluoroscopy. Br J Radiol 1985;58:187-8.
-
(1985)
Br. J. Radiol.
, vol.58
, pp. 187-188
-
-
Law, J.1
-
16
-
-
0020045876
-
An assessment of the radiation dose received by staff using fluoroscopic equipment
-
Faulkner K, Moores BM. An assessment of the radiation dose received by staff using fluoroscopic equipment. Br J Radiol 1982;55:272-6.
-
(1982)
Br. J. Radiol.
, vol.55
, pp. 272-276
-
-
Faulkner, K.1
Moores, B.M.2
-
17
-
-
0030955533
-
The interdependence of staff and patient doses in interventional radiology
-
Williams JR. The interdependence of staff and patient doses in interventional radiology. Br J Radiol 1997;70:498-503.
-
(1997)
Br. J. Radiol.
, vol.70
, pp. 498-503
-
-
Williams, J.R.1
-
18
-
-
16344377788
-
-
The Ionising Radiations Regulations. 1999 SI 1999/3232 Stationery Office ISBN 0 11 0856147
-
The Ionising Radiations Regulations. 1999 SI 1999/3232 Stationery Office 1999 ISBN 0 11 0856147.
-
(1999)
-
-
-
19
-
-
0032929829
-
Variations in dose to the extremities of vascular/interventional radiologists
-
Anderson NE, King SH, Miller KL. Variations in dose to the extremities of vascular/interventional radiologists. Health Physics 1999;76 (Suppl. 2):39-40.
-
(1999)
Health Physics
, vol.76
, Issue.SUPPL. 2
, pp. 39-40
-
-
Anderson, N.E.1
King, S.H.2
Miller, K.L.3
-
20
-
-
16344379441
-
Radiation measurements
-
Chapter 4. Martin CJ, Sutton DG (editors). Oxford: Oxford University Press
-
Green S, Zamenhof RG. Radiation measurements. Chapter 4. In: Martin CJ, Sutton DG (editors). Practical Radiation Protection in Healthcare. Oxford: Oxford University Press, 2002:58-9.
-
(2002)
Practical Radiation Protection in Healthcare
, pp. 58-59
-
-
Green, S.1
Zamenhof, R.G.2
-
21
-
-
0005545886
-
Conversion coefficients for use in radiological protection against external radiation
-
International Commission on Radiological Protection (ICRP). Publication No. 74. Annals of the ICRP Oxford: Pergamon Press
-
International Commission on Radiological Protection (ICRP). Conversion coefficients for use in radiological protection against external radiation. Publication No. 74. Annals of the ICRP, Vol. 26, 3-4. Oxford: Pergamon Press, 1997.
-
(1997)
, vol.26
, pp. 3-4
-
-
-
23
-
-
0038693131
-
Radiation doses to the legs of radiologists performing interventional procedures: Are they a cause for concern?
-
Whitby M, Martin CJ. Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern? Br J Radiol 2003;76:321-7.
-
(2003)
Br. J. Radiol.
, vol.76
, pp. 321-327
-
-
Whitby, M.1
Martin, C.J.2
-
24
-
-
0742271723
-
Application of ALARP to extremity doses for hospital workers
-
Martin CJ, Whitby M. Application of ALARP to extremity doses for hospital workers. J Radiol Prot 2003;23:405-21.
-
(2003)
J. Radiol. Prot.
, vol.23
, pp. 405-421
-
-
Martin, C.J.1
Whitby, M.2
-
25
-
-
0030186719
-
Radiation protection of the hand in interventional radiology: Should it fit like a glove?
-
Marx MV, Ellis JH. Radiation protection of the hand in interventional radiology: Should it fit like a glove? Radiology 1996;200:24-5.
-
(1996)
Radiology
, vol.200
, pp. 24-25
-
-
Marx, M.V.1
Ellis, J.H.2
|