메뉴 건너뛰기




Volumn 12, Issue , 2011, Pages

Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: Useful in research and individual patient settings? A reliability study

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; DYNAMOMETRY; FEMALE; HOSPITAL ADMISSION; HUMAN; INTERRATER RELIABILITY; ISOMETRICS; KNEE FUNCTION; MALE; MUSCLE STRENGTH; OSTEOARTHRITIS; TOTAL KNEE REPLACEMENT; ARTHRALGIA; CLINICAL TRIAL; CONVALESCENCE; DYNAMOMETER; KNEE; KNEE ARTHROPLASTY; KNEE OSTEOARTHRITIS; MIDDLE AGED; MUSCLE ISOMETRIC CONTRACTION; OBSERVER VARIATION; PATHOPHYSIOLOGY; PHYSIOLOGY; PREOPERATIVE CARE; STANDARD; VALIDATION STUDY;

EID: 80055011883     PISSN: None     EISSN: 14712474     Source Type: Journal    
DOI: 10.1186/1471-2474-12-249     Document Type: Article
Times cited : (93)

References (39)
  • 1
    • 1242332345 scopus 로고    scopus 로고
    • Public health classics: Inflammation as an important feature of osteoarthritis
    • 14710513
    • Public health classics: Inflammation as an important feature of osteoarthritis. Brooks PJ, Bull World Health Organ 2003 81 689 690 14710513
    • (2003) Bull World Health Organ , vol.81 , pp. 689-690
    • Brooks, P.J.1
  • 4
    • 70349876436 scopus 로고    scopus 로고
    • Muscle deficits persist after unilateral knee replacement and have implications for rehabilitation
    • 10.2522/ptj.20070295 19713269
    • Muscle deficits persist after unilateral knee replacement and have implications for rehabilitation. Valtonen A, Poyhonen T, Heinonen A, Sipila S, Phys Ther 2009 89 1072 1079 10.2522/ptj.20070295 19713269
    • (2009) Phys Ther , vol.89 , pp. 1072-1079
    • Valtonen, A.1    Poyhonen, T.2    Heinonen, A.3    Sipila, S.4
  • 5
    • 74249093353 scopus 로고    scopus 로고
    • Reliability and validity of measurements of knee extension strength obtained from nursing home residents with dementia
    • 10.1097/PHM.0b013e3181ae1003 19661779
    • Reliability and validity of measurements of knee extension strength obtained from nursing home residents with dementia. Suzuki M, Yamada S, Inamura A, Omori Y, Kirimoto H, Sugimura S, Miyamoto M, Am J Phys Med Rehabil 2009 88 11 924 933 10.1097/PHM.0b013e3181ae1003 19661779
    • (2009) Am J Phys Med Rehabil , vol.88 , Issue.11 , pp. 924-933
    • Suzuki, M.1    Yamada, S.2    Inamura, A.3    Omori, Y.4    Kirimoto, H.5    Sugimura, S.6    Miyamoto, M.7
  • 6
    • 26444456638 scopus 로고    scopus 로고
    • Reliability and validity of static knee strength measurements obtained with a chair-fixed dynamometer in subjects with hip or knee arthroplasty
    • DOI 10.1016/j.apmr.2005.04.013, PII S0003999305004016
    • Reliability and validity of static knee strength measurements obtained with a chair-fixed dynamometer in subjects with hip or knee arthroplasty. Gagnon D, Nadeau S, Gravel D, Robert J, Belanger D, Hilsenrath M, Arch Phys Med Rehabil 2005 86 1998 2008 10.1016/j.apmr.2005.04.013 16213245 (Pubitemid 41423631)
    • (2005) Archives of Physical Medicine and Rehabilitation , vol.86 , Issue.10 , pp. 1998-2008
    • Gagnon, D.1    Nadeau, S.2    Gravel, D.3    Robert, J.4    Belanger, D.5    Hilsenrath, M.6
  • 7
    • 0032709731 scopus 로고    scopus 로고
    • Isometric strength measurements in children with arthritis: Reliability and relation to function
    • Isometric strength measurements in children with arthritis: reliability and relation to function. Wessel J, Kaup C, Fan J, Ehalt R, Ellsworth J, Speer C, Tenove P, Dombrosky A, Arthritis Care Res 1999 12 238 246 10.1002/1529-0131(199908)12:4<238::AID-ART2>3.0.CO;2-I 10689988 (Pubitemid 29508655)
    • (1999) Arthritis Care and Research , vol.12 , Issue.4 , pp. 238-246
    • Wessel, J.1    Kaup, C.2    Fan, J.3    Ehalt, R.4    Ellsworth, J.5    Speer, C.6    Tenove, P.7    Dombrosky, A.8
  • 10
    • 73949155246 scopus 로고    scopus 로고
    • Assessment of hip and knee muscle function in orthopaedic practice and research
    • 10.2106/JBJS.I.00305 20048117
    • Assessment of hip and knee muscle function in orthopaedic practice and research. Maffiuletti NA, J Bone Joint Surg Am 2010 92 220 229 10.2106/JBJS.I.00305 20048117
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 220-229
    • Maffiuletti, N.A.1
  • 11
    • 0036893762 scopus 로고    scopus 로고
    • Quantitative testing of muscle strength: Issues and practical options for the geriatric population
    • Quantitative testing of muscle strength: Issues and practical options for the geriatric population. Bohannon RW, Top Geriatr Rehabil 2002 17 35
    • (2002) Top Geriatr Rehabil , pp. 17-35
    • Bohannon, R.W.1
  • 12
    • 67249163411 scopus 로고    scopus 로고
    • Reproducibility of an isokinetic strength-testing protocol of the knee and ankle in older adults
    • 10.1159/000172832 18997454
    • Reproducibility of an isokinetic strength-testing protocol of the knee and ankle in older adults. Hartmann A, Knols R, Murer K, de Bruin ED, Gerontology 2009 55 259 268 10.1159/000172832 18997454
    • (2009) Gerontology , vol.55 , pp. 259-268
    • Hartmann, A.1    Knols, R.2    Murer, K.3    De Bruin, E.D.4
  • 13
    • 33744960352 scopus 로고    scopus 로고
    • Development of a strength test battery for evaluating leg muscle power after anterior cruciate ligament injury and reconstruction
    • DOI 10.1007/s00167-006-0040-y
    • Development of a strength test battery for evaluating leg muscle power after anterior cruciate ligament injury and reconstruction. Neeter C, Gustavsson A, Thomee P, Augustsson J, Thomee R, Karlsson J, Knee Surg Sports Traumatol Arthrosc 2006 14 571 580 10.1007/s00167-006-0040-y 16477472 (Pubitemid 43854298)
    • (2006) Knee Surgery, Sports Traumatology, Arthroscopy , vol.14 , Issue.6 , pp. 571-580
    • Neeter, C.1    Gustavsson, A.2    Thomee, P.3    Augustsson, J.4    Thomee, R.5    Karlsson, J.6
  • 14
    • 63849292343 scopus 로고    scopus 로고
    • Hand-held dynamometry in patients with haematological malignancies: Measurement error in the clinical assessment of knee extension strength
    • 10.1186/1471-2474-10-31 19272149
    • Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength. Knols RH, Aufdemkampe G, de Bruin ED, Uebelhart D, Aaronson NK, BMC Musculoskelet Disord 2009 10 31 10.1186/1471-2474-10-31 19272149
    • (2009) BMC Musculoskelet Disord , vol.10 , pp. 31
    • Knols, R.H.1    Aufdemkampe, G.2    De Bruin, E.D.3    Uebelhart, D.4    Aaronson, N.K.5
  • 15
    • 56149119418 scopus 로고    scopus 로고
    • Hand-held dynamometry in children with traumatic brain injury: Within-session reliability
    • 10.1097/PEP.0b013e3181824782 18703964
    • Hand-held dynamometry in children with traumatic brain injury: within-session reliability. Katz-Leurer M, Rottem H, Meyer S, Pediatr Phys Ther 2008 20 259 263 10.1097/PEP.0b013e3181824782 18703964
    • (2008) Pediatr Phys Ther , vol.20 , pp. 259-263
    • Katz-Leurer, M.1    Rottem, H.2    Meyer, S.3
  • 16
    • 0035104065 scopus 로고    scopus 로고
    • Hip abductor and knee extensor muscle strength of children with and without down syndrome
    • Hip Abductor and Knee Extensor Muscle Strength of Children with and without Down Syndrome. Mercer VS, Lewis CL, Pediatr Phys Ther 2001 13 18 26 10.1097/00001577-200104000-00004 17053646 (Pubitemid 32223495)
    • (2001) Pediatric Physical Therapy , vol.13 , Issue.1 , pp. 18-26
    • Mercer, V.S.1    Lewis, C.L.2
  • 17
    • 33744471396 scopus 로고    scopus 로고
    • Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard biodex dynamometry
    • DOI 10.1159/000091824
    • Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Bodex dynamometry. Martin HJ, Yule V, Syddall HE, Dennison EM, Cooper C, Aihie SA, Gerontology 2006 52 154 159 10.1159/000091824 16645295 (Pubitemid 43800677)
    • (2006) Gerontology , vol.52 , Issue.3 , pp. 154-159
    • Martin, H.J.1    Yule, V.2    Syddall, H.E.3    Dennison, E.M.4    Cooper, C.5    Aihie Sayer, A.6
  • 18
    • 33845892103 scopus 로고    scopus 로고
    • Measuring Muscle Strength for People With Chronic Obstructive Pulmonary Disease: Retest Reliability of Hand-Held Dynamometry
    • DOI 10.1016/j.apmr.2006.10.002, PII S0003999306013700
    • Measuring muscle strength for people with chronic obstructive pulmonary disease: retest reliability of hand-held dynamometry. O'Shea SD, Taylor NF, Paratz JD, Arch Phys Med Rehabil 2007 88 32 36 10.1016/j.apmr.2006.10.002 17207672 (Pubitemid 46026736)
    • (2007) Archives of Physical Medicine and Rehabilitation , vol.88 , Issue.1 , pp. 32-36
    • O'Shea, S.D.1    Taylor, N.F.2    Paratz, J.D.3
  • 19
    • 85044491636 scopus 로고    scopus 로고
    • Inter-Rater Reliability for Function and Strength Measurements in the Acute Care Hospital after Elective Hip and Knee Arthroplasty
    • Inter-rater reliability for function and strength measurements in the acute care hospital after elective hip and knee arthroplasty. Kwoh CK, Petrick MA, Munin MC, Arthr Care Res 1997 10 128 134 10.1002/art.1790100208 (Pubitemid 127502724)
    • (1997) Arthritis Care and Research , vol.10 , Issue.2 , pp. 128-134
    • Kwoh, C.K.1    Petrick, M.A.2    Munin, M.C.3
  • 20
    • 0026795811 scopus 로고    scopus 로고
    • Reliability of hand-held dynamometry and its relationship with manual muscle testing in patients with osteoarthritis in the knee
    • Reliability of hand-held dynamometry and its relationship with manual muscle testing in patients with osteoarthritis in the knee. Hayes KW, Falconer J, J Orthop Sports Phys Ther 2010 3 145 149
    • (2010) J Orthop Sports Phys Ther , vol.3 , pp. 145-149
    • Hayes, K.W.1    Falconer, J.2
  • 22
    • 0037440945 scopus 로고    scopus 로고
    • Isometric muscle force measurement for clinicians treating patients with osteoarthritis of the knee
    • Isometric muscle force measurement for clinicians treating patients with osteoarthritis of the knee. Fransen M, Crosbie J, Edmonds J, Arthritis Rheum 2003 49 29 35 10.1002/art.10923 12579591 (Pubitemid 36286127)
    • (2003) Arthritis Care and Research , vol.49 , Issue.1 , pp. 29-35
    • Fransen, M.1    Crosbie, J.2    Edmonds, J.3
  • 23
    • 40849096256 scopus 로고    scopus 로고
    • The reliability of isometric strength and fatigue measures in patients with knee osteoarthritis
    • DOI 10.1016/j.math.2006.12.003, PII S1356689X06001792
    • The reliability of isometric strength and fatigue measures in patients with knee osteoarthritis. McCarthy C, Callaghan M, Oldham J, Man Ther 2008 13 159 64 10.1016/j.math.2006.12.003 17296324 (Pubitemid 351391986)
    • (2008) Manual Therapy , vol.13 , Issue.2 , pp. 159-164
    • McCarthy, C.J.1    Callaghan, M.J.2    Oldham, J.A.3
  • 24
    • 13244270015 scopus 로고    scopus 로고
    • Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy
    • DOI 10.1097/01.PEP.0000145932.21460.61
    • Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy. Berry ET, Giuliani CA, Damiano DL, Pediatr Phys Ther 2004 16 191 198 10.1097/01.PEP.0000145932.21460.61 17057548 (Pubitemid 40186460)
    • (2004) Pediatric Physical Therapy , vol.16 , Issue.4 , pp. 191-198
    • Berry, E.T.1    Giuliani, C.A.2    Damiano, D.L.3
  • 25
    • 0027155544 scopus 로고
    • The application of generalizability theory to reliability assessment: An illustration using isometric force measurements
    • 8497513
    • The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Roebroek ME, Harlaar J, Lankhorst GJ, Phys Ther 1993 73 386 395 8497513
    • (1993) Phys Ther , vol.73 , pp. 386-395
    • Roebroek, M.E.1    Harlaar, J.2    Lankhorst, G.J.3
  • 26
    • 84976979820 scopus 로고
    • The clinical measurement of strength
    • 10.1177/026921558700100103
    • The clinical measurement of strength. Bohannon RW, Clin Rehabil 1987 1 05 16 10.1177/026921558700100103
    • (1987) Clin Rehabil , vol.1 , pp. 05-16
    • Bohannon, R.W.1
  • 27
    • 21344437280 scopus 로고    scopus 로고
    • Break-technique handheld dynamometry: Relation between angular velocity and strength measurements
    • DOI 10.1016/j.apmr.2004.12.041, PII S000399930500225X
    • Break-technique handheld dynamometry: relation between angular velocity and strength measurements. Burns SP, Spanier DE, Arch Phys Med Rehabil 2005 86 1420 1426 10.1016/j.apmr.2004.12.041 16003675 (Pubitemid 40909912)
    • (2005) Archives of Physical Medicine and Rehabilitation , vol.86 , Issue.7 , pp. 1420-1426
    • Burns, S.P.1    Spanier, D.E.2
  • 28
    • 33847385395 scopus 로고    scopus 로고
    • Hand-held dynamometry for muscle strength measurement in children with cerebral palsy
    • DOI 10.1111/j.1469-8749.2007.00106.x
    • Hand-held dynamometry for muscle strength measurement in children with cerebral palsy. Crompton J, Galea MP, Phillips B, Dev Med Child Neurol 2007 49 106 111 10.1111/j.1469-8749.2007.00106.x 17253996 (Pubitemid 46336280)
    • (2007) Developmental Medicine and Child Neurology , vol.49 , Issue.2 , pp. 106-111
    • Crompton, J.1    Galea, M.P.2    Phillips, B.3
  • 31
    • 36849000732 scopus 로고    scopus 로고
    • Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: Comparison of a new device with hand-held dynamometry
    • DOI 10.2340/16501977-0107
    • Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: comparison of a new device with hand-held dynamometry. Lu TW, Hsu HC, Chang LY, Chen HL, J Rehabil Med 2007 39 679 684 10.2340/16501977-0107 17999004 (Pubitemid 350226150)
    • (2007) Journal of Rehabilitation Medicine , vol.39 , Issue.9 , pp. 679-684
    • Lu, T.-W.1    Hsu, H.-C.2    Chang, L.-Y.3    Chen, H.-L.4
  • 34
    • 7244226137 scopus 로고    scopus 로고
    • Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture
    • DOI 10.1097/01.PHM.0000143405.17932.78
    • Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture. Roy MA, Doherty TJ, Am J Phys Med Rehabil 2004 83 813 818 10.1097/01.PHM.0000143405.17932.78 15502733 (Pubitemid 39431036)
    • (2004) American Journal of Physical Medicine and Rehabilitation , vol.83 , Issue.11 , pp. 813-818
    • Roy, M.-A.G.1    Doherty, T.J.2
  • 35
    • 18144370459 scopus 로고    scopus 로고
    • Early quadriceps strength loss after total knee arthroplasty: The contributions of muscle atrophy and failure of voluntary muscle activation
    • DOI 10.2106/JBJS.D.01992
    • Early quadriceps strength loss after total knee arthroplasty. The contributions of muscle atrophy and failure of voluntary muscle activation. Mizner RL, Petterson SC, Stevens JE, Vandenborne K, Snyder-Mackler L, J Bone Joint Surg Am 2005 87 1047 1053 10.2106/JBJS.D.01992 15866968 (Pubitemid 40617573)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.5 , pp. 1047-1053
    • Mizner, R.L.1    Petterson, S.C.2    Stevens, J.E.3    Vandenborne, K.4    Snyder-Mackler, L.5
  • 36
    • 0041887020 scopus 로고    scopus 로고
    • Quadriceps strength and volitional activation before and after total knee arthroplasty for osteoarthritis
    • DOI 10.1016/S0736-0266(03)00052-4
    • Quadriceps strength and volitional activation before and after total knee arthroplasty for osteoarthritis. Stevens JE, Mizner RL, Snyder-Mackler L, J Orthop Res 2003 21 775 779 10.1016/S0736-0266(03)00052-4 12919862 (Pubitemid 37045553)
    • (2003) Journal of Orthopaedic Research , vol.21 , Issue.5 , pp. 775-779
    • Stevens, J.E.1    Mizner, R.L.2    Snyder-Mackler, L.3
  • 37
    • 39149144520 scopus 로고    scopus 로고
    • Examining outcomes from total knee arthroplasty and the relationship between quadriceps strength and knee function over time
    • DOI 10.1016/j.clinbiomech.2007.10.008, PII S0268003307002446
    • Examining outcomes from total knee arthroplasty and the relationship between quadriceps strength and knee function over time. Yoshida Y, Mizner RL, Ramsey DK, Snyder-Mackler L, Clin Biomech (Bristol, Avon) 2008 23 320 328 10.1016/j.clinbiomech.2007.10.008 (Pubitemid 351253719)
    • (2008) Clinical Biomechanics , vol.23 , Issue.3 , pp. 320-328
    • Yoshida, Y.1    Mizner, R.L.2    Ramsey, D.K.3    Snyder-Mackler, L.4
  • 38
    • 0032900999 scopus 로고    scopus 로고
    • Early changes in muscle strength after total knee arthroplasty. A 6-month follow-up of 30 knees
    • Early changes in muscle strength after total knee arthroplasty. A 6-month follow-up of 30 knees. Lorentzen JS, Petersen MM, Brot C, Madsen OR, Acta Orthop Scand 1999 70 176 179 10.3109/17453679909011258 10366920 (Pubitemid 29221724)
    • (1999) Acta Orthopaedica Scandinavica , vol.70 , Issue.2 , pp. 176-179
    • Lorentzen, J.S.1    Petersen, M.M.2    Brot, C.3    Madsen, O.R.4
  • 39
    • 34447335363 scopus 로고    scopus 로고
    • Psychosocial stress factors among patients with lumbar disc herniation, scheduled for disc surgery in comparison with patients scheduled for arthroscopic knee surgery
    • DOI 10.1007/s00586-007-0319-9
    • Psychosocial stress factors among patients with lumbar disc herniation, scheduled for disc surgery in comparison with patients scheduled for arthroscopic knee surgery. Johansson AC, Cornefjord M, Bergkvist L, Ohrvik J, Linton SJ, Eur Spine J 2007 16 961 970 10.1007/s00586-007-0319-9 17347823 (Pubitemid 47063469)
    • (2007) European Spine Journal , vol.16 , Issue.7 , pp. 961-970
    • Johansson, A.-C.1    Cornefjord, M.2    Bergkvist, L.3    Ohrvik, J.4    Linton, S.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.