메뉴 건너뛰기




Volumn 20, Issue 3, 2008, Pages 259-263

Hand-held dynamometry in children with traumatic brain injury: Within-session reliability

Author keywords

Child; Human movement system; Lower limb; Muscle strength dynamometer; Reliability; Traumatic brain injury

Indexed keywords

AGE DISTRIBUTION; ARTICLE; CHILD; CHILD DEVELOPMENT; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; DYNAMOMETRY; FEMALE; HUMAN; INTRARATER RELIABILITY; LEG; LEG MUSCLE; MALE; MEASUREMENT ERROR; MUSCLE STRENGTH; SCHOOL CHILD; TRAUMATIC BRAIN INJURY; ADOLESCENT; BRAIN INJURY; CASE CONTROL STUDY; COMPARATIVE STUDY; DYNAMOMETER; HIP; INSTRUMENTATION; ISRAEL; KNEE; PATHOPHYSIOLOGY; PHYSIOLOGY; PHYSIOTHERAPY; REPRODUCIBILITY; STANDARD; VALIDATION STUDY;

EID: 56149119418     PISSN: 08985669     EISSN: None     Source Type: Journal    
DOI: 10.1097/PEP.0b013e3181824782     Document Type: Article
Times cited : (14)

References (22)
  • 1
    • 0027409270 scopus 로고
    • Motor performance in children after traumatic brain injury
    • Chaplin D, Deitz J, Jaffe KM. Motor performance in children after traumatic brain injury. Arch Phys Med Rehabil. 1993;74:161-164.
    • (1993) Arch Phys Med Rehabil , vol.74 , pp. 161-164
    • Chaplin, D.1    Deitz, J.2    Jaffe, K.M.3
  • 2
    • 4544369755 scopus 로고    scopus 로고
    • Recovery of the precision grip in children after traumatic brain injury
    • Golge M, Muller M, Dreesmann M, et al. Recovery of the precision grip in children after traumatic brain injury. Arch Phys Med Rehabil. 2004;85:1435-1444.
    • (2004) Arch Phys Med Rehabil , vol.85 , pp. 1435-1444
    • Golge, M.1    Muller, M.2    Dreesmann, M.3
  • 3
    • 0038779537 scopus 로고    scopus 로고
    • A randomized controlled trial of the effects of intensive sit-to-stand training after recent traumatic brain injury on sit-to-stand performance
    • Canning CG, Shepherd RB, Carr JH, et al. A randomized controlled trial of the effects of intensive sit-to-stand training after recent traumatic brain injury on sit-to-stand performance. Clin Rehabil. 2003; 17:355-362.
    • (2003) Clin Rehabil , vol.17 , pp. 355-362
    • Canning, C.G.1    Shepherd, R.B.2    Carr, J.H.3
  • 4
    • 13444257664 scopus 로고    scopus 로고
    • Effects of circuit training on body composition and peak cardiorespiratory responses in patients with moderate to severe traumatic brain injury
    • Bhambhani Y,RowlandG, Farag M.Effects of circuit training on body composition and peak cardiorespiratory responses in patients with moderate to severe traumatic brain injury. Arch Phys Med Rehabil. 2005;86:268-276.
    • (2005) Arch Phys Med Rehabil , vol.86 , pp. 268-276
    • Bhambhani, Y.1    Rowland, G.2    Farag, M.3
  • 5
    • 33644975337 scopus 로고    scopus 로고
    • Ability of very young children to produce reliable isometric force measurements
    • Gajdosik CG. Ability of very young children to produce reliable isometric force measurements. Pediatr Phys Ther. 2005;17:251-257.
    • (2005) Pediatr Phys Ther , vol.17 , pp. 251-257
    • Gajdosik, C.G.1
  • 6
    • 0347989563 scopus 로고    scopus 로고
    • Test-retest reliability of hand-held dynamometric strength testing in young people with cerebral palsy
    • Taylor NF, Dodd KJ, Graham HK. Test-retest reliability of hand-held dynamometric strength testing in young people with cerebral palsy. Arch Phys Med Rehabil. 2004;85:77-80.
    • (2004) Arch Phys Med Rehabil , vol.85 , pp. 77-80
    • Taylor, N.F.1    Dodd, K.J.2    Graham, H.K.3
  • 7
    • 13244270015 scopus 로고    scopus 로고
    • Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy
    • Berry E, Giuliani C. Damiano, D. Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy. Pediatr Phys Ther. 2004;16:191-198.
    • (2004) Pediatr Phys Ther , vol.16 , pp. 191-198
    • Berry, E.1    Giuliani, C.2    Damiano, D.3
  • 8
    • 33847385395 scopus 로고    scopus 로고
    • Hand-held dynamometry for muscle strength measurement in children with cerebral palsy
    • Crompton J, Galea MP, Phillips B. Hand-held dynamometry for muscle strength measurement in children with cerebral palsy. Dev Med Child Neurol. 2007;49:106-111.
    • (2007) Dev Med Child Neurol , vol.49 , pp. 106-111
    • Crompton, J.1    Galea, M.P.2    Phillips, B.3
  • 9
    • 0024504606 scopus 로고
    • Intrasession and inter-session reliability of hand-held dynamometer measurements taken on brain-damaged patients
    • Riddle DL, Finucane SD, Rothstein JM, et al. Intrasession and inter-session reliability of hand-held dynamometer measurements taken on brain-damaged patients. Phys Ther. 1989;69:182-194.
    • (1989) Phys Ther , vol.69 , pp. 182-194
    • Riddle, D.L.1    Finucane, S.D.2    Rothstein, J.M.3
  • 10
    • 1842475499 scopus 로고    scopus 로고
    • Validity and reliability of the measurement of the quadriceps femoris muscle strength with a handheld dynamometer on the affected side in hemiplegic patients
    • Piao C, Yoshimoto N, Shitama H, et al. Validity and reliability of the measurement of the quadriceps femoris muscle strength with a handheld dynamometer on the affected side in hemiplegic patients. J UOEH. 2004;26:1-11.
    • (2004) J UOEH , vol.26 , pp. 1-11
    • Piao, C.1    Yoshimoto, N.2    Shitama, H.3
  • 11
    • 0001871114 scopus 로고
    • Effects of isokinetic exercise on adolescents with cerebral palsy
    • McCubbin JA, Shasby GB. Effects of isokinetic exercise on adolescents with cerebral palsy. Adapted Phys Activity Q. 1985;2:56-64.
    • (1985) Adapted Phys Activity Q , vol.2 , pp. 56-64
    • McCubbin, J.A.1    Shasby, G.B.2
  • 12
    • 0024602298 scopus 로고
    • Is the measurement of muscle strength appropriate in patients with brain lesions?: A special communication
    • Bohannon RW. Is the measurement of muscle strength appropriate in patients with brain lesions?: a special communication. Phys Ther. 1989;69:225-236.
    • (1989) Phys Ther , vol.69 , pp. 225-236
    • Bohannon, R.W.1
  • 14
    • 0016391336 scopus 로고
    • Assessment of coma and impaired consciousness. A practical scale
    • Teasdale G, Jennett B. Assessment of coma and impaired consciousness. A practical scale. Lancet. 1974;2:81-84.
    • (1974) Lancet , vol.2 , pp. 81-84
    • Teasdale, G.1    Jennett, B.2
  • 15
    • 0023130157 scopus 로고
    • Interrater reliability of a modified Ash-worth scale of muscle spasticity
    • Bohannon RW, Smith MB. Interrater reliability of a modified Ash-worth scale of muscle spasticity. Phys Ther. 1987;67:206-207.
    • (1987) Phys Ther , vol.67 , pp. 206-207
    • Bohannon, R.W.1    Smith, M.B.2
  • 16
    • 0003052524 scopus 로고
    • Testing isometric limb muscle strength with dynamometers
    • Bohannon RW. Testing isometric limb muscle strength with dynamometers. Crit Rev Phys Med Rehabil. 1990;2:75-86.
    • (1990) Crit Rev Phys Med Rehabil , vol.2 , pp. 75-86
    • Bohannon, R.W.1
  • 17
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Srout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-428.
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Srout, P.E.1    Fleiss, J.L.2
  • 18
    • 0030814146 scopus 로고    scopus 로고
    • Use of the standard error as a reliability index of interest: An applied example using elbow flexor strength data
    • Stratford PW, Goldsmith CH. Use of the standard error as a reliability index of interest: an applied example using elbow flexor strength data. Phys Ther. 1997;77:745-750.
    • (1997) Phys Ther , vol.77 , pp. 745-750
    • Stratford, P.W.1    Goldsmith, C.H.2
  • 19
    • 0035104065 scopus 로고    scopus 로고
    • Hip abductor and knee extensor muscle strength of children with and without Down syndrome
    • Mercer V, Lewis C. Hip abductor and knee extensor muscle strength of children with and without Down syndrome. Pediatr Phys Ther. 2001;13:18-26.
    • (2001) Pediatr Phys Ther , vol.13 , pp. 18-26
    • Mercer, V.1    Lewis, C.2
  • 20
    • 0023863061 scopus 로고
    • Make tests and break tests of elbow flexor muscle strength
    • Bohannon RW. Make tests and break tests of elbow flexor muscle strength. Phys Ther. 1988;68:193-194.
    • (1988) Phys Ther , vol.68 , pp. 193-194
    • Bohannon, R.W.1
  • 21
    • 0028137854 scopus 로고
    • A comparison of make and break tests using a hand-held dynamometer and the Kin-Com
    • Stratford PW, Balsor BE. A comparison of make and break tests using a hand-held dynamometer and the Kin-Com. J Orthop Sports Phys Ther 1994;19:28-32.
    • (1994) J Orthop Sports Phys Ther , vol.19 , pp. 28-32
    • Stratford, P.W.1    Balsor, B.E.2
  • 22
    • 15744385505 scopus 로고    scopus 로고
    • Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
    • Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. 2005;19:231-240.
    • (2005) J Strength Cond Res , vol.19 , pp. 231-240
    • Weir, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.